Lennox 090V36C - Manual
Lennox 090V36C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – FRONT VIEW
- Page 3 – Parts Arrangement; FIGURE 1
- Page 4 – SLP98DFV Gas Furnace; NOTE; Shipping and Packing List; Package 1 of 1 contains; Safety Information; WARNING; Building Codes
- Page 5 – or; AIR HANDLER; CAUTION; Use of Furnace as Construction Heater
- Page 6 – General; Product contains fiberglass wool.; Installation − Setting Equipment; The unit must be level from side to side. Unit may; Unit must be level side−to−side. Unit may be positioned
- Page 7 – Do; Downflow Application Installation Clearances; FIGURE 7
- Page 8 – B Cabinet
- Page 9 – Return Air Opening −− Downflow Units; Side View; Side View; Filters; TABLE 3; Furnace; Duct System
- Page 10 – Pipe & Fittings Specifications; TABLE 4; IMPORTANT; Canadian Applications Only
- Page 11 – Joint Cementing Procedure; DANGER; NOTE −
- Page 12 – Venting Practices; Piping Suspension Guidelines; Wall Thickness Guidelines; Vent Piping Guidelines
- Page 13 – btuh
- Page 16 – TOP VIEW; TYPICAL AIR INTAKE PIPE CONNECTIONS; TOP VIEW
- Page 18 – FIELD−SUPPLIED WALL TERMINATION OR; Vent Pipe; STRAIGHT
- Page 20 – − On field−supplied terminations for side wall exit, ex-
- Page 25 – SL98DFV with Evaporator Coil; Gas Piping; Leak Check; FIRE OR EXPLOSION HAZARD
- Page 26 – GAS PIPE CAPACITY − FT
- Page 27 – Electrical; Precautions and Procedures; INTERIOR MAKE−UP BOX
- Page 28 – NOTE − Do NOT make a wire connection between; Run Length Communicating; Thermostat Selection
- Page 35 – TYPICAL SLP98DFV WIRING DIAGRAM
- Page 36 – Integrated Control; INTEGRATED CONTROL
- Page 37 – Continuous Indoor Blower Operation −− Blower Speeds
- Page 39 – Normal; On−Board Links
- Page 40 – BLOWER DATA
- Page 42 – HEATING BLOWER PERFORMANCE; COOLING BLOWER PERFORMANCE
- Page 43 – NO CALL FOR DEHUMIDIFICATION
- Page 45 – Unit Start−Up
- Page 46 – High Altitude Information; Gas Pressure Measurement
- Page 47 – Proper Combustion; Use pressure test; Do not attempt to make adjustments to the gas valve.; Other Unit Adjustments
- Page 48 – Heating Sequence of Operation
- Page 49 – Applications Using A Single−Stage Thermostat
- Page 50 – Service
- Page 52 – Planned Service
- Page 53 – Integrated Control Diagnostic Codes
- Page 54 – Integrated Control Diagnostic Codes (continued)
- Page 56 – Configuring Unit Size Code; FINISHED
- Page 57 – Troubleshooting: Heating Sequence of Operation; IGNITION AND CALL FOR LOW FIRE WITH TWO−STAGE
- Page 58 – CALL FOR HIGH FIRE WITH TWO−STAGE THERMOSTAT
- Page 59 – CALL FOR HEAT SATISFIED
- Page 60 – IGNITION AND CALL FOR HEAT WITH SINGLE−STAGE THERMOSTAT
- Page 61 – Troubleshooting: Cooling Sequence of Operation; CALL FOR COOLING
- Page 62 – Troubleshooting: Continuous Fan Sequence of Operation; CONTINUOUS LOW SPEED INDOOR BLOWER SEQUENCE OF OPERATION
- Page 63 – Repair Parts List; All service must be performed by a licensed profes-
- Page 64 – Requirements for Commonwealth of Massachusetts; Modifications to NFPA−54, Chapter 10
Page 1
02/11
*2P0211*
506611−01
*P506611-01*
2011 Lennox Industries Inc.
Dallas, Texas, USA
AIR FLOW
DOWNFLOW
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
INSTALLATION
INSTRUCTIONS
SLP98DFV
DAVE LENNOX SIGNATURE
®
COLLECTION GAS FURNACE
DOWNFLOW AIR DISCHARGE
506611−01
02/2011
Supersedes 10/2010
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
This is a safety alert symbol and should never be ignored.
When you see this symbol on labels or in manuals, be alert
to the potential for personal injury or death.
CAUTION
As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.
NOTICE
A thermostat is not included and must be ordered
separately.
The Lennox icomfort Touch
thermostat must be
used in communicating applications.
In non−communicating applications, the Lennox
ComfortSense
®
7000 thermostat may be used, as
well as other non−communicating thermostats.
In all cases, setup is critical to ensure proper sys-
tem operation.
Field wiring for both communicating and non−com-
municating applications is illustrated in diagrams,
which begin on Page 30.
Table of Contents
Unit Dimensions
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Arrangement
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SLP98DFV Gas Furnace
4
. . . . . . . . . . . . . . . . . . . . . . . . .
Shipping and Packing List
4
. . . . . . . . . . . . . . . . . . . . . . . .
Safety Information
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Use of Furnace as a Construction Heater
5
. . . . . . . . . . .
General
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Equipment
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filters
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duct System
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pipe and Fittings Specifications
10
. . . . . . . . . . . . . . . . . . .
Joint Cementing Procedure
11
. . . . . . . . . . . . . . . . . . . . . .
Venting Practices
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vent Piping Guidelines
12
. . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Piping
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Integrated Control
36
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor Performance
40
. . . . . . . . . . . . . . . . . . . . . . .
Unit Start Up
45
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Pressure Measurement
46
. . . . . . . . . . . . . . . . . . . . .
High Altitude Information
46
. . . . . . . . . . . . . . . . . . . . . . . .
Proper Combustions
47
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Other Unit Adjustments
46
. . . . . . . . . . . . . . . . . . . . . . . . . .
Heating Sequence of Operation
48
. . . . . . . . . . . . . . . . . .
Service
50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Planned Service
52
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Integrated Control Diagnostic Codes
53
. . . . . . . . . . . . . .
Configuring Unit Size Codes
56
. . . . . . . . . . . . . . . . . . . . .
Troubleshooting
57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repair Parts List
63
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Litho U.S.A.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 Unit Dimensions − inches (mm) AIR EXHAUST AIR OUTLET COMBUSTION AIR INTAKE FLOW 2 − 1/16 (52) 090V48C A B C D SLP98DF Model No. in. mm in. mm in. mm in. mm 070V36B 17 − 1/2 446 16 − 3/8 416 16 406 7 − 5/8 194 090V36C 21 533 19 − 7/8 505 19 − 1/2 495 9 − 3/8 238 090V60C 110V60C GAS PIPING INLE...
Page 3 Parts Arrangement FIGURE 1 BURNER BOX ASSEMBLY GAS VALVE ACCESS PANEL COMBUSTION AIR INDUCER BLOWER ACCESS PANEL BLOWER ASSEMBLY (Variable Speed Blower Motor Is Hidden) BAG ASSEMBLY CONTROL BOX (includes variable capacity integrated control, transformer, circuit breaker and door switch) PRIMA...
Page 4 SLP98DFV Gas Furnace The SLP98DFV category IV gas furnace is equipped witha variable−capacity, variable−speed integrated control.This control ensures compatibility with the Lennox icom-fort Touch thermostat and Harmony III zone control system, as well as a thermostat which provides humidityco...