Page 2 - Meanings of symbols used in this manual are shown below:; environmental tips; Information on disposal for users; • Most of the packing materials are recyclable.; warning; Conditions of use; Congratulations
2 contents Kelvinator Gas Continuous Flow hot water system Congratulations and thank you for choosing our gas continuous flow hot water system. Before you install the hot water system, we recommend that you read through the entire installation manual, which provides the description of the hot water ...
Page 3 - For the installer; Gas Appliance Installation; This symbol indicates never to do this; Important
This Installation Manual has been prepared for the installers of the gas continuous flow hot water system. For the installer The installation must be completed in accordance with the information supplied in this Installation Manual. All other relevant National, State or Local regulations must also b...
Page 4 - Keep flammable products:; BEFORE OPERATING; Important safety instructions
4 impor tant safety instruc tions Kelvinator Gas Continuous Flow hot water system warning Vapours from flammable liquids will explode and catch fire causing death or severe burns. Do not use or store flammable products such as gasoline, solvents or adhesives near the water heater. Keep flammable pro...
Page 5 - For the plumber; PLEASE NOTE; MODELS
Kelvinator Gas Continuous Flow hot water system for the plumber 5 For the plumber PLEASE NOTE this water heater is supplied factory set to comply with the requirements of AS 3498. If you are installing a 60°C or 70°C preset water heater, a tempering valve is to be installed for the hot water supplyi...
Page 6 - Exterior view –
6 dimensions - KGC20*** Kelvinator Gas Continuous Flow hot water system Exterior view – KGC20*** 124mm 49 0m m 52 0m m 31 m m p o w er 47 m m g as 133mm 94mm60mm 198mm 350mm top fixing positions top fixing positions hot 98 m m 70 m m 10 8m m 30 m m cold gas 335mm Kelvinator Gas Continuous Flow hot w...
Page 8 - caution; Installation
8 installation Kelvinator Gas Continuous Flow hot water system The water heater requires careful and correct installation to ensure safe and efficient operation. This manual must be followed exactly. Read the SAFETY GUIDELINES and the IMPORTANT sections at the beginning of this manual. Confirm the w...
Page 9 - Clearances for outdoor heater locations –; Reference
Kelvinator Gas Continuous Flow hot water system clearances 9 Clearances for outdoor heater locations – AS5601 f c k k j j j h h h T Tg e e a d b c g T d see note 2 T – Flue terminal I – Mechanical air inlet M – Gas meter P – Elec tricity meter or fuse box Shading indicates prohibited areas for flue ...
Page 10 - Gas connection
Purging the gas supply line before connection Before connecting the gas supply inlet piping to the water heater it must be purged of foreign matter. Before purging the gas supply line confirm that the electrical supply to the water heater is turned off, there is adequate ventilation available and th...
Page 11 - Water connection
gate or ball valve on inlet filter 1. Turn off the water inlet supply valve.2. Open a hot water tap to release the line pressure.3. Remove the filter by turning it counterclockwise. Clean under running water with an old toothbrush then replace. NOTE: This filter is designed to be cleaned as part of ...
Page 12 - Electrical connection; Weather-proof power outlet; Wiring diagram; IG; FM
12 elec trical connec tion Kelvinator Gas Continuous Flow hot water system Electrical connection 1. The water heater must be electrically grounded. Please ensure that the earth on the outlet that the supply cord connects to is wired correctly. If in doubt check the continuity of the earth at the out...
Page 13 - MAIN remote controller KGCMRC*; SHOWER and ENSUITE remote controllers
Kelvinator Gas Continuous Flow hot water system remote controller 13 Remote controller (optional) The water heater can be installed with up to three remote controllers (one of each type), a MAIN controller, a SHOWER controller and an ENSUITE controller. The primary function of the remote controller ...
Page 14 - Remote controller installation; Crimp the lugs provided to the remote controller wiring.; Install the wiring downward through the cable trench and
14 remote controller installation Kelvinator Gas Continuous Flow hot water system Remote controller installation 1. Crimp the lugs provided to the remote controller wiring. Minimum 18AWG wire (No polarity).・Maximum 100m long 2. If installing the MAIN remote controller, attach the crimped fork lugs o...
Page 15 - Connection of remote controller; screws on the front cover.; Replace the plastic cover and the front cover and connect; Remote control cable connections
Kelvinator Gas Continuous Flow hot water system remote controller installation 15 Connection of remote controller wiring to the water heater 1. Turn off the power supply to the water heater. 2. Remove the front cover from the water heater. There are 3 screws on the front cover. 3. Put the remote wir...
Page 16 - Commissioning instructions
Before commissioning the gas continuous flow hot water system, please confirm the following: • Installation location and clearances are correct as per AS5601 • Gas and water supply lines have been purged of foreign matter • Correct gas type has been connected to the water heater • There are no gas l...
Page 18 - Troubleshooting; Temperature and amount of hot water
18 troubleshooting Kelvinator Gas Continuous Flow hot water system Troubleshooting Temperature and amount of hot water Problem Possible solutions It takes a long time for hot water to reach the fixtures. The time it takes to deliver hot water from the water heater to your fixtures depends on the len...
Page 19 - Remote controller and PCB error codes; Error codes on the remote controller and PCB; LED on the PCB
Kelvinator Gas Continuous Flow hot water system Remote controller and PCB error codes 19 Remote controller and PCB error codes When remote controller is not installed When remote controller is installed The error code will be displayed on the remote controller. 1 2 3 4 5 6 7 8 The LED on the PCB wil...
Page 20 - Notes
20 notes Kelvinator Gas Continuous Flow hot water system Notes
Page 23 - Warranty; Important Notice
Kelvinator Gas Continuous Flow hot water system warranty 23 This document sets out the terms and conditions of the product warranties for Electrolux Appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference should you require s...