Page 2 - Table 1; JUNOSe System Basics Configuration Guide
This guide provides an overview and description of the line modules (LMs), switchroute processor (SRP) modules, switch fabric modules (SFMs), and input/outputadapters (IOAs) available for the E320 router. NOTE: A release may support multiple versions of a module or IOA. For information, see Software...
Page 3 - Table 1: E320 Modules and IOAs; Page
Table 1: E320 Modules and IOAs Page First JUNOSe Support Module Label Module/IOA Type Line Module 5 7.0.1 ES2 4G LM LM-4 7 7.2.0 ES2 10G UPLINK LM LM-10 Uplink 9 8.0.0 ES2 10G LM LM-10 SRP Module 11 7.0.1 SRP-100 SRP-100 13 7.3.0 SRP-320 SRP-320 SFM Module 15 7.0.1 SFM-100 SFM-100 16 7.3.0 SFM-320 S...
Page 8 - ONLINE (green)—Online with no alarms or errors; See
When lit, LED indicates: ■ OK (green)—Self-test passed ■ FAIL (red)—Failure detected ■ ONLINE (green)—Online with no alarms or errors ■ REDUN (green)—Redundant card available LEDs ■ See Monitoring Modules in JUNOSe System Basics Configuration Guide, Chapter 6, Managing Modules . Alarms, errors, and ...
Page 20 - E320 Hardware Guide, Chapter 5, Cabling the Router; Monitoring Ethernet Interfaces; Table 2: SX Fiber Optic Cabling; Table 3: LX Fiber Optic Cabling; Table 4: LX40 Fiber Optic Cabling
■ Up to four LC-style fiber-optic connectors ■ Transmit power: ■ min: –2 dBm ■ max: 3 dBm ■ Receive input power: ■ min: –22 dBm ■ max: –3 dBm ■ See the following corresponding table (ZX Fiber Optic Cabling) for cablingrequirements. ■ See E320 Hardware Guide, Chapter 5, Cabling the Router for more in...
Page 21 - Table 5: ZX Fiber Optic Cabling
Table 5: ZX Fiber Optic Cabling Maximum Operating Range (kilometers) Nominal Wavelength (nm) Fiber Type 70 (43.5 miles) 1550 10 microns GE-4 IOA ■ 21 GE-4 IOA
Page 24 - Table 6: SX Fiber Optic Cabling; Table 7: LX Fiber Optic Cabling; Table 8: LX40 Fiber Optic Cabling
■ One LC full duplex connector ■ Transmit power: ■ min: –2 dBm ■ max: 3dBm ■ Receive input power: ■ min: –22 dBm ■ max: –3 dBm ■ See the following corresponding table (ZX Fiber Optic Cabling) for cablingrequirements. ■ See E320 Hardware Guide, Chapter 5, Cabling the Router for more information. Cabl...
Page 25 - microns; Table 9: ZX Fiber Optic Cabling
Table 8: LX40 Fiber Optic Cabling (continued) 40 (24.85 miles) 1310 9 microns Table 9: ZX Fiber Optic Cabling Maximum Operating Range (kilometers) Nominal Wavelength (nm) Fiber Type 70 (43.5 miles) 1550 10 microns GE-8 IOA ■ 25 GE-8 IOA
Page 28 - Table 10: SR Fiber Optic Cabling; Table 11: LR Fiber Optic Cabling; Table 12: ER Fiber Optic Cabling
Table 10: SR Fiber Optic Cabling Maximum Operating Range (meters) Minimal Modal Bandwidth at850 nm (MHz*km) Fiber Type 26 (85.3 ft) 160 62.5 microns 33 (108.27 ft) 200 66 (216.54 ft) 400 50 microns 82 (269.03 ft) 500 300 (984.25 ft) 2000 Table 11: LR Fiber Optic Cabling Maximum Operating Range(kilom...
Page 32 - Table 13: SR Fiber Optic Cabling; Table 14: LR Fiber Optic Cabling; Table 15: ER Fiber Optic Cabling
Table 13: SR Fiber Optic Cabling Maximum Operating Range (meters) Minimal Modal Bandwidth at850 nm (MHz*km) Fiber Type 26 (85.3 ft) 160 62.5 microns 33 (108.27 ft) 200 66 (216.54 ft) 400 50 microns 82 (269.03 ft) 500 300 (984.25 ft) 2000 Table 14: LR Fiber Optic Cabling Maximum Operating Range(kilom...
Page 34 - Monitoring SONET/SDH Interfaces
■ Up to eight LC full duplex connectors ■ Transmit power: ■ min: –15 dBm ■ max: –8 dBm ■ Center wavelength: 1310 nm ■ Receive input power: ■ min: –34 dBm ■ max: –7 dBm ■ Rated for 15 km (9.3 miles) of 9-micron core cable ■ See E320 Hardware Guide, Chapter 5, Cabling the Router for more information. ...
Page 42 - Monitoring Modules
Redundancy IOA ES2-S1 REDUND IOA IOA label ■ 0 Number of IOA ports ■ First supported: 7.0.1 Software release ■ 10 W ■ Full-height module ■ Provides redundancy for line modules ■ Inserted in slot 0 and 11 only Description ■ Provides switchover when a line module fails ■ Provides N+1 redundancy for li...
Page 43 - Monitoring Tunnel-Service Interfaces
Service IOA ES2-S1 SERVICE IOA IOA label ■ 0 Number of IOA ports ■ First supported: 7.0.1 Software release ■ 10 W ■ Full-height module ■ Provides tunnel server functionality ■ Pairs with associated line module to receive data from and transmit data toother line modules with ingress and egress ports ...
Page 45 - Appendix A; IOA Protocol Support; on page 3 for a list of IOAs and their identifying labels.; Ethernet IOAs; Table 16: Ethernet IOAs with ES2 4G LM; Protocol or Application
Appendix A IOA Protocol Support This appendix lists the layer 2 and layer 3 protocols and applications that IOAs supportin combination with the listed LM. IOAs are identified by their physical labels. See Table 1 on page 3 for a list of IOAs and their identifying labels. The designation “not yet ful...
Page 48 - Table 17: Ethernet IOAs with ES2 10G Uplink LM
Table 17: Ethernet IOAs with ES2 10G Uplink LM ES2–S2 10GE PR IOA (with ES2 10G Uplink LM) Protocol or Application Yes Accepts traffic destined for GRE tunnels or DVMRP (IP-in-IP)tunnels No APS/MSP No ATM No BERT Yes BGP No BGP/MPLS VPNs No Bridged Ethernet No Bridged IP No CBF No Cisco HDLC Yes DHC...
Page 50 - Table 18: Ethernet IOAs with ES2 10G LM
Table 18: Ethernet IOAs with ES2 10G LM ES2–S2 10GE PR IOA (with ES2 10GLM) ES2–S1 GE-8 IOA (with ES2 10G LM) Protocol or Application Yes Yes Accepts traffic destined for GRE tunnelsor DVMRP (IP-in-IP) tunnels No No APS/MSP No No ATM No No BERT Yes Yes BGP No No BGP/MPLS VPNs No No Bridged Ethernet ...
Page 59 - Table 21: Service IOA; ES2–S1 SERVICE IOA
Service IOA Table 21: Service IOA ES2–S1 SERVICE IOA Protocol or Application No Accepts traffic destined for GRE tunnels or DVMRP (IP-in-IP) tunnels No APS/MSP No ATM No BERT Yes BGP Yes BGP/MPLS VPNs No Bridged Ethernet No Bridged IP No CBF No Cisco HDLC No DHCP external server No DHCP local server...
Page 63 - Appendix B; Slot Combinations; IOA Slot Combinations; For information about working with modules and IOAs, see; Table 22: E320 IOA Locations and Combinations; IOA
Appendix B Slot Combinations This appendix lists the IOA slot combinations and contains the following sections: ■ IOA Slot Combinations on page 63 IOA Slot Combinations Depending on the software release and IOA type, you must install IOAs in certainslots and bays combined with other IOAs in the same...
Page 65 - Appendix C; Module Name Cross-Reference Information; Use; Table 23: Module Naming Reference; Model Number
Appendix C Module Name Cross-ReferenceInformation ■ Module Name Cross-Reference Information on page 65 Module Name Cross-Reference Information Use Table 23 on page 65 to find the label name, software display name, and model number of a module. Table 23: Module Naming Reference Model Number Software ...
Page 67 - Appendix D; Product Reclamation and Recycling Program; Waste Electrical and Electronic Equipment
Appendix D Product Reclamation and RecyclingProgram ■ Product Reclamation and Recycling Program on page 67 Product Reclamation and Recycling Program Juniper Networks is committed to environmentally responsible behavior. As part ofthis commitment, we continually work to comply with environmental stan...