Johnson Controls 16 - Manual

Johnson Controls 16

Johnson Controls 16 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 2 – Johnson Controls Unitary Products; SAFETY; SINGLE SPLIT SYSTEM; EQUIPMENT MODEL NUMBERS
  • Page 3 – DUCTLESS SYSTEM OPERATION; MUTI-SPLITS APPLICATION ONLY; TYPICAL INSTALLATION; SINGLE SPLIT
  • Page 5 – REMOTE CONTROL; NOTICE; NOTICE
  • Page 6 – TIMER ON BUTTON; GENERAL OPERATION
  • Page 7 – MAINTENANCE; OUTDOOR UNIT; INSTALLATION AND MAINTENANCE OF; INSTALLATION OF HEALTHY FILTER (REFER TO; TROUBLESHOOTING
  • Page 9 – Limited Warranty
  • Page 10 – York International Corp.; EXCLUSIONS: This warranty does not cover any:
Loading the manual

Johnson Controls Unitary Products

898147-UUM-B-0713

USER’S INFORMATION MANUAL

SINGLE AND MULTI-ZONE DUCTLESS SYSTEM

AIR CONDITIONER OR HEAT PUMP

MODELS: 16 & 22 SEER

TABLE OF CONTENTS

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DUCTLESS SYSTEM DEFFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . 2
EQUIPMENT MODEL NUMBERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DUCTLESS SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . 3
TYPICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REMOTE CONTROL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

GENERAL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
REMOTE CONTROL BATTERIES REPLACEMENT . . . . . . . . . . . . .6
EMERGENCY OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
INSTALLATION AND MAINTENANCE OF HEALTHY FILTER . . . . .7
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

CONTACT INFORMATION

Go to website at www.york.com, then click on “Contact Us” and
follow the instructions.

Contact us by mail:

Johnson Controls Unitary Products

Consumer Relations

5005 York Drive

Norman, OK 73069

Read this manual and keep for future reference.

GENERAL

This Manual is a guide to help assist with the operation of this ductless
system. It does not contain the service procedures that have to be per-
formed by a qualified HVAC service technician.

LX SERIES

PREMIUM
SERIES

• Make sure you read this manual before you start operating your

new ductless system.

• After reading this manual, if you still need more information that

may not have been covered in this manual, please contact your
HVAC contractor.

• To ensure comfort, make sure that temperature selection has

been properly set at the remote control. To ensure efficient oper-
ation, do not block air intake or outlet at either the indoor or out-
door unit. Also, do not stand nor put items on top of outdoor and
indoor units.

• If any issues with your system were to arise, please contact your

HVAC contractor.

• Make sure your windows and doors are shut when operating

your ductless system.

The refrigerant inside your ductless product uses PVE oil (Polyvinyl
Ether Oil) that readily absorbs moisture from the atmosphere. To limit
this “hygroscopic” action, the system should remain sealed whenever
possible. If a system has been open to the atmosphere for more than
4 hours, the compressor oil must be replaced. Do not break a vac-
uum with air and always change the driers when opening the system
for component replacement. For specific handling concerns with PVE
oil, contact your HVAC contractor. Failure to follow these recommen-
dations could result in equipment damage.

NOTICE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Johnson Controls Unitary Products; SAFETY; SINGLE SPLIT SYSTEM; EQUIPMENT MODEL NUMBERS

898147-UUM-B-0713 2 Johnson Controls Unitary Products SAFETY DUCTLESS SYSTEM DEFFINITIONS SINGLE SPLIT SYSTEM A single split system consists of a single outdoor unit and a singleindoor unit. The single split system is controlled using a remote control(included with indoor unit). MULTI-SPLIT SYSTEM A...

Page 3 - DUCTLESS SYSTEM OPERATION; MUTI-SPLITS APPLICATION ONLY; TYPICAL INSTALLATION; SINGLE SPLIT

898147-UUM-B-0713 Johnson Controls Unitary Products 3 DUCTLESS SYSTEM OPERATION MUTI-SPLITS APPLICATION ONLY In a multi-split application, the operating mode is determined by thezone that initiates the first demand for heating or cooling. If the systemis energized and a heating demand has been initi...

Page 5 - REMOTE CONTROL; NOTICE; NOTICE

898147-UUM-B-0713 Johnson Controls Unitary Products 5 REMOTE CONTROL OPERATION The wireless remote control gives the home-owner the ability to operate their ductless sys-tem at the touch of a button. The indoor unitand remote control send information back andforth continuously. The remote control mu...

Other Johnson Controls Models