- Page 2 – RANGE SAFETY; Your safety and the safety of others are very important.; DANGER; WHAT TO DO IF YOU SMELL GAS:
- Page 3 – WARNING
- Page 4 – INSTALLATION REQUIREMENTS; Tools and Parts; Tools Needed; Optional Parts
- Page 5 – Location Requirements; Mobile Home – Additional Installation Requirements; Mobile Home Installations Require:; Product Dimensions
- Page 6 – Cabinet Dimensions
- Page 7 – Venting Requirements; For Best Performance:
- Page 8 – Calculating Vent System Length; Vent Piece; Maximum length
- Page 9 – Electrical Connection; Specified Rating of; Electrical Shock Hazard
- Page 10 – Electrical Requirements – Canada Only; Gas Supply Requirements; Type of Gas
- Page 12 – INSTALLATION INSTRUCTIONS; Unpack Range; Install Anti-Tip Bracket
- Page 13 – Position the Blower Location Template
- Page 14 – Install the Downdraft System; Rear Wall Venting
- Page 15 – Floor Venting
- Page 16 – Make Gas Connection; Typical Flexible Connection; Complete Connection; Level Range
- Page 17 – Install Blower; Install Blower Cover
- Page 18 – Connect Blower Electrical Parts
- Page 19 – Initial Lighting and Gas Flame Adjustments; If Burners Do Not Light Properly:; Adjust Leveling Legs
- Page 22 – GAS CONVERSIONS; Propane Gas Conversion; To Convert Gas Pressure Regulator
- Page 23 – To Convert Surface Burners (Natural Gas to Propane; ID; Large Burner
- Page 24 – Natural Gas Conversion; Complete Installation (Natural Gas to Propane Gas)
- Page 25 – Complete Installation (Propane Gas to Natural Gas); Color; To Convert Surface Burners (Propane Gas to Natural
- Page 26 – Adjust Flame Height; Adjust Surface Burner Flame; If the “Low” Flame Needs to be Adjusted:
INSTALLATION INSTRUCTIONS
SLIDE-IN DOWNDRAFT RANGES
INSTRUCTIONS D’INSTALLATION
DES CUISINIÈRES À ÉVACUATION PAR LE BAS
ENCASTRABLES
W11259377A
RANGE SAFETY ....................................................................... 2
INSTALLATION REQUIREMENTS .......................................... 4
Tools and Parts .................................................................... 4
Location Requirements ....................................................... 5
Venting Requirements ......................................................... 7
Electrical Requirements – U.S.A. Only ................................ 9
Electrical Requirements – Canada Only ............................ 10
Gas Supply Requirements ................................................. 10
INSTALLATION INSTRUCTIONS ......................................... 12
Unpack Range ................................................................... 12
Install Anti-Tip Bracket ....................................................... 12
Position the Blower Location Template ............................. 13
Install the Downdraft System ............................................ 14
Make Gas Connection ........................................................ 16
Level Range ........................................................................ 16
Install Blower ...................................................................... 17
Adjust Leveling Legs ......................................................... 19
Verify Anti-Tip Bracket Is Installed and Engaged ............... 19
Electronic Ignition System .................................................. 19
Oven Door ......................................................................... 20
Complete Installation .......................................................... 20
GAS CONVERSIONS ............................................................ 22
Propane Gas Conversion ................................................... 22
Natural Gas Conversion ..................................................... 24
Adjust Flame Height ........................................................... 26
SÉCURITÉ DE LA CUISINIÈRE ........................................... 27
EXIGENCES D’INSTALLATION ........................................... 29
Outils et pièces .................................................................. 29
Exigences d’emplacement ................................................ 30
Exigences concernant l’évacuation ................................... 32
Spécifications électriques – Canada seulement ................ 34
Spécifications de l’alimentation en gaz .............................. 34
INSTRUCTIONS D’INSTALLATION ..................................... 36
Déballage de la cuisinière ................................................... 36
Installation de la bride antibasculement ............................. 36
Positionnement du gabarit indiquant l’emplacement
du ventilateur ..................................................................... 37
Installation du circuit d’évacuation par le bas ................... 38
Raccordement au gaz ........................................................ 40
Réglage de l’aplomb de la cuisinière ................................. 40
Installation du ventilateur
................................................... 41
Réglage des pieds de nivellement .................................... 43
Vérifier que la bride antibasculement est bien installée
et engagée ........................................................................... 43
Système d’allumage électronique ...................................... 43
Porte du four ....................................................................... 44
Achever l’installation .......................................................... 44
CONVERSIONS POUR CHANGEMENT DE GAZ ................ 46
Conversion pour l’alimentation au propane ....................... 46
Conversion pour l’alimentation au gaz naturel ................... 48
Réglage de la taille des flammes ........................................ 50
Table of Contents/Table des matières
IMPORTANT:
Save for local electrical inspector’s use.
IMPORTANT :
À conserver pour consultation par l’inspecteur local des installations électriques.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for JennAir JDS1750FP0
Summary
2 RANGE SAFETY You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what canhappen if the instructions are n...
3 In the State of Massachusetts, the following installation instructions apply: ■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by the State of Massachusetts. ■ Acceptable Shut-off Devices: Gas Cocks and Ball Valves in...
4 INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed ■ Tape measure ■ Phillips screwdriver ■ Flat-blade screwdriver ■ 1/8 " (3 mm) flat- blade screwdriver ■...