Jackson TSC-66 - Manual
Jackson TSC-66 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Conveyors; Specifications; P R E WA S H P U M P M OTO R :
- Page 4 – Unit shall have the following features as optional extras:
- Page 5 – Left to Right Operation Shown
- Page 6 – Right to Left Operation Shown
Performance/Capacities
Conveyor
s
TS C -6 6 Traditional
Series
• 119 racks per hour hi-temp sanitizing
rinse.
• 0 . 5 5 g a l l o n s p e r r a c k h i - t e m p
sanitizing rinse.
• Incoming water pressure regulator
• Standard 18” clearance.
• Totally electro-mechanical; no solid
state controls utilized.
• Fully automatic including auto-fill.
• Completely self-draining st ainless
steel wash pump.
• Exclusive “Energy Guard” controls
s y s t e m o p e r a t e s w a s h a n d r i n s e
sections only when a rack is being
washed or rinsed.
• A long 16” wash section as well as
18” separation between wash and
rinse produces superior results.
• C o n v e n i e n t , e x t e r n a l l y o p e r a t e d
lever drain.
• Stainless steel frame, legs, adjustable
bullet feet, and front appearance panel
are all standard.
• S t a n d a r d 8 ” v e n t c o w l s / s p l a s h
shields on both wash and rinse ends
of the machine.
• Heavy gauge construction for extra
ruggedness and durability.
Standard Features
Operating Capacity
Racks per hour
Hi-temp Sanitization
119
Dishes per hour
Hi-temp Sanitization
2975
Glasses per hour
Hi-temp Sanitization
2975
Steam Coil Tank Heat
Steam Connection IPS (Inches)
3/4
Steam Flow Pressure (PSIG)
10-20
Consumption @ 15 PSIG (Lbs/hr) 60
Wash Pump Motor HP
2
Wash Pump Capacity (GPM)
270
Wash Tank KW
15
Prewash Pump Motor HP
1
Prewash Pump Capacity (GPM) 120
Conveyor Motor Horsepower
1/4
Conveyor Speed (Feet/minute)
Hi-temp Sanitization
3.3
Operating Temperatures
Prewash Tank–°F
110 - 140
Wash Tank–°F (Minimum)
Hi-temp Sanitization
160
Rinse–°F (Minimum)
Hi-temp Sanitization
180
Dimensions (Inches)
Length between dishtables
66
Machine width
30-3/4
Wall Clearance (Minimum)
4
Cavity/dish clearance (Maximum)
18
Cavity width
20-1/2
Shipping Information
Weight (Lbs)
894
Dimensions (Inches)
Length
96
Depth
40
Height
78
Volume (Cubic feet)
174
Approximate Total Load
AMPS
208V / 60HZ / 3PH
51.8
208V / 60HZ / 1PH
88.3
230V / 60HZ / 3PH
47.8
230V / 60HZ / 1PH
81.5
460V / 60HZ / 3PH
23.9
Booster Heater Options
External 40°F Min. Rise
KW
AMPS
208V / 60HZ / 3PH
7
29.0
230V / 60HZ / 3PH
7
25.0
460V / 60HZ / 3PH
7
13.0
External 70°F Min. Rise
KW
AMPS
208V / 60HZ / 3 PH
12
33.0
230V / 60HZ / 3PH
12
29.0
460V / 60HZ / 3PH
12
14.5
Venting Requirements (CFM)
Input end
200
Output end
400
Total CFM
600
Water Requirements
Incoming Water Temperature (°F)
180
With 7 KW booster heater option (°F)
140
With 12 KW booster heater option (°F)
110
Gallons per hour:
Hi-temp sanitization
66
Gallons per rack:
Hi-temp sanitization
0.55
Prewash Tank Capacity (Gallons) 17.25
Wash Tank Capacity (Gallons)
20.4
Incoming Waterline Sizes (IPS) (Minimum)
1/2
Flow Pressure (PSI)
15-25
Flow Rate Minimum (GPM)
Hi-temp sanitization
3.9
Drainline Size IPS (Minimum) (Inches)
1 1/2
Power/Connections
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Conveyors TS C -6 6 TraditionalSeries Specifications NOTE: The TSC-66 series conveyor dishmachines are N S F I n t e r n a t i o n a l I n c . ( N S F ) a n d U n d e r w r i t e r s Laboratories Inc. (UL) listed. They also meet the require- ments of A.S.S.E. Standard No. 1004. PERFORMANCE: Fully au...
Specifications Conveyors w w w . j a c k s o n m s c . c o m 1 - 8 8 8 - 8 0 0 - 5 6 7 2 TS C -6 6 TraditionalSeries Note: Check and/or copy all that apply.TSC-66 Series Rack Conveyor Dishwasher — Item No. ____________ Shall be a Jackson TSC-66 series, single tank rack conveyor dishwasher.Sanitizati...
TS C -6 6 TraditionalSeries Left to Right Operation Shown Legend to Drawing A – Machine water inlet 1/2” I.P.S., 180°F minimum, 61- 1/4” above finished floor B – Electrical connection , approximately 61-1/4” above finished floor. See table for amperage requirements C – Drain connection-1 1/2” I.P.S....