Page 2 - WARNING; ACCESSORIES; There are many different types of humidifiers, oxygen tubing,; WARNING
WARNING Platinum ™ Series 2 Part No 1118353 WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS, AND INSTRUCTIONS, CONTACT INVACARE TECHNICAL SERVICES BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE SER...
Page 3 - TABLE OF CONTENTS; Oxygen Purity Indicator (If Your Unit Features
TABLE OF CONTENTS Part No 1118353 3 Platinum ™ Series ACCESSORIES .................................................. 2SPECIAL NOTES ............................................... 5SECTION 1—GENERAL GUIDELINES .................. 6 Maintenance.............................................................
Page 5 - SPECIAL NOTES; NOTICE; SIGNAL WORD
SPECIAL NOTES Part No 1118353 5 Platinum ™ Series SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definitions of the signal words NOTICE The information contained in...
Page 6 - SECTION 1—GENERAL GUIDELINES; CAUTION
SECTION 1—GENERAL GUIDELINES Platinum ™ Series 6 Part No 1118353 SECTION 1—GENERAL GUIDELINES In order to ensure the safe installation, assembly and operation of the Platinum concentrator these instructions MUST be followed. CAUTION “Caution: Federal law restricts this device to sale or rental by or...
Page 8 - Maintenance
SECTION 1—GENERAL GUIDELINES Platinum ™ Series 8 Part No 1118353 WARNING NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air opening may be blocked. Keep the openings free from lint, hair and the like. Fill humidifier with water to the lev...
Page 9 - To Reduce The Risk Of Burns,
SECTION 1—GENERAL GUIDELINES Part No 1118353 9 Platinum ™ Series WARNING To Reduce The Risk Of Burns, Electrocution, Fire Or Injury To Persons. Avoid using while bathing. If continuous usage is required by the physician’s prescription: The concentrator MUST be located in another room at least seven ...
Page 10 - Polarized Plug Instruction
SECTION 1—GENERAL GUIDELINES Platinum ™ Series 10 Part No 1118353 WARNING Use of some administration accessories or certain humidifiers not specified for use with oxygen concentrator may impair the performance.In certain circumstances oxygen therapy can be hazardous. Invacare recommends that you see...
Page 11 - SECTION 2—FEATURES
SECTION 2—FEATURES Part No 1118353 11 Platinum ™ Series SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights (SensO 2 model only)/ Fault and Power Indicator Lights (LX model only) Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter (one of two shown) REAR VIEW ACCESSO...
Page 12 - SECTION 3—HANDLING; Unpacking; Inspection
SECTION 3—HANDLING Platinum ™ Series 12 Part No 1118353 SECTION 3—HANDLING The concentrator should ALWAYS be kept in the upright position to prevent cabinet damage while being transported. The shipping container has been designed to assure maximum protection of the concentrator. If the concentrator ...
Page 13 - SECTION 4—SPECIFICATIONS; *NOTE: Stated concentration levels achieved after initial warm-up
SECTION 4—SPECIFICATIONS Part No 1118353 13 Platinum ™ Series SECTION 4—SPECIFICATIONS *NOTE: Stated concentration levels achieved after initial warm-up period (approximately 30 minutes). Electrical Requirements: 120 VAC ± 10% (132 VAC/108 VAC), 60 Hz Rated Current Input: Platinum 5 and XL: 4.3 A Pl...
Page 17 - NOTES
Page 20 - REGISTER YOUR PRODUCT!; Complete form and mail.; PRODUCT REGISTRATION FORM
REGISTER YOUR PRODUCT! The benefits of registering: 1. Safeguard your investment. 2. Ensure long term maintenance and servicing of your purchase. 3. Receive updates with product information, maintenance tips, and industrynews. 4. Invacare can contact you or your provider, if servicing is needed on y...
Page 23 - SECTION 5—OPERATING INSTRUCTIONS; SECTION 5—; OPERATING; Introduction
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 23 Platinum ™ Series SECTION 5— OPERATING INSTRUCTIONS Introduction Your oxygen concentrator is intended for individual use in the home. It is an electronically operated device that separates oxygen from room air. It provides high concentration of oxy...
Page 24 - Recommended Guidelines for Optimum; NOTE: Ensure that your concentrator is at least three inches away; Plug in Power Cord; Plug in power cord to an electrical outlet.
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 24 Part No 1118353 Recommended Guidelines for Optimum Performance NOTE: Ensure that your concentrator is at least three inches away from walls, draperies or furniture to assure sufficient air flow. Avoid deep pile carpets and heaters, radiators or h...
Page 25 - connections. Water from the humidifier bottle will travel
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 25 Platinum ™ Series Connect Humidifier (If So Prescribed) NOTE: For this procedure, refer to FIGURE 5.1 - FIGURE 5.4.NOTE: Fill humidifier with distilled water to the level indicated by the manufacturer. (For Platinum 5, XL - recommended humidifiers ...
Page 26 - Attaching the Humidifier Bottle Adapter
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 26 Part No 1118353 3. Remove the filter access door located on the side of the concentrator. Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door open. Refer to Detail “A” ...
Page 27 - Attaching the Oxygen Tubing; For optimum performance, Invacare recommends that; Power Switch
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 27 Platinum ™ Series 6. Attach oxygen tubing from the humidifier bottle to oxygen outlet connector on the oxygen concentrator (FIGURE 5.4). 7. Attach the cannula/patient supply tubing to the humidifier bottle outlet (FIGURE 5.4). 8. After assembly, en...
Page 28 - Flowrate; DO NOT change the L/min. setting on the flowmeter
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 28 Part No 1118353 FIGURE 5.5 Power Switch Flowrate NOTE: For this procedure, refer to FIGURE 5.6 on page 29. 1. Turn the flowrate knob to the setting prescribed by your physician or therapist. WARNING DO NOT change the L/min. setting on the flowmet...
Page 30 - continue to use the concentrator unless instructed otherwise; Indicators (If Your Unit Does Not; LX models indicator Light Explanation; IMMEDIATELY to a back-up oxygen supply. Call supplier; Normal
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 30 Part No 1118353 YELLOW light ( ) - Call supplier IMMEDIATELY. You may continue to use the concentrator unless instructed otherwise by your supplier. Be certain that backup oxygen is nearby.RED light ( )- Total unit shutdown. Switch IMMEDIATELY to...
Page 31 - Indicators (If Your Unit Does Not Feature the O
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 31 Platinum ™ Series FIGURE 5.8 Indicators (If Your Unit Does Not Feature the O 2 Sensor) Call Supplier Normal RED GREEN Auto Shut - Down Use Backup I/O
Page 32 - SECTION 6—MAINTENANCE; Cleaning the Cabinet Filter; Remove each filter and clean at least once a week
SECTION 6—MAINTENANCE Platinum ™ Series 32 Part No 1118353 SECTION 6—MAINTENANCE NOTE: The Invacare concentrators are specifically designed to minimize routine preventive maintenance. In places with high dust or soot levels, maintenance may need to be performed more often. Only authorized or factory...
Page 33 - DO NOT operate the concentrator without the filters; Cabinet; UNPLUG the concentrator when cleaning. To avoid; Humidifier; NOTE: To clean the oxygen humidifier, follow the instructions
SECTION 6—MAINTENANCE Part No 1118353 33 Platinum ™ Series CAUTION DO NOT operate the concentrator without the filters installed. FIGURE 6.1 Cleaning the Cabinet Filter Cabinet WARNING UNPLUG the concentrator when cleaning. To avoid electrical shock, DO NOT remove cabinet. 1. Clean the cabinet with ...
Page 34 - DO NOT overfill humidifier bottle.
SECTION 6—MAINTENANCE Platinum ™ Series 34 Part No 1118353 WARNING DO NOT overfill humidifier bottle. FIGURE 6.2 Preventive Maintenance Record ON EACH INSPECTION MODEL NO. I R C SERIAL NO. PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR Record Date of Service Record Elapsed Hours...
Page 35 - SECTION 7—TROUBLESHOOTING GUIDE; SECTION 7—TROUBLESHOOTING
SECTION 7—TROUBLESHOOTING GUIDE Part No 1118353 35 Platinum ™ Series SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Main Power Loss: 1. Insert plug into outlet. SHORT BEEPS, LONG PAUSE 1. Power cord NOT plugged in. 2. Inspect house circuit breakers or fuses. If problem rec...
Page 38 - LIMITED WARRANTY
LIMITED WARRANTY Platinum ™ Series 38 Part No 1118353 LIMITED WARRANTY NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.This warranty is extended only to the original purchaser who purchases this product when new and unused f...
Page 40 - This product may be manufactured under one or more of the
Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 Technical Services 800-832-4707 Invacare, Yes, you can., SensO 2 , and the Medallion Design are registered trademarks of Invacare Corporation. Platinum, HomeFill, Sieve-Gard, Precise R X are trademark...