Page 2 - WARNING; NOTICE; The information contained in this document is subject to; WARNING; NOTE: Updated versions of this manual are available on
WARNING HomeFill ™ II Compressor 2 Part No 1100873 WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE DANGERS, WARNINGS, CAUTIONS, AND INSTRUCTIONS, CONTACT INVACARE TECHNICAL SERVICES BEFORE ATTEMPTING TO USE THIS EQUIPMENT...
Page 3 - TABLE OF CONTENTS
TABLE OF CONTENTS TABLE OF CONTENTS HomeFill ™ II Compressor 3 Part No 1100873 SPECIAL NOTES ............................................... 4TYPICAL PRODUCT ......................................... 5PARAMETERS ................................................. 5LABEL LOCATION .........................
Page 4 - SPECIAL NOTES; Invacare products are specifically designed and
SPECIAL NOTES HomeFill ™ II Compressor 4 Part No 1100873 SPECIAL NOTES Check all parts for shipping damage. In case of damage, DO NOT use. Contact Invacare for further instruction.Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or p...
Page 5 - TYPICAL PRODUCT; Operating temperature:; Input Pressure Required:
Part No 1100873 5 HomeFill ™ II Compressor TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS - COMPRESSOR Regulatory Listing: Double Insulated Product ETL Certified Complying with UL73 and UL1097 (US)ETL Certified Complying with CAN/CSA C22.2 No. 68 (Canada)For household use only. Operating temp...
Page 6 - LABEL LOCATION; DEALER INFORMATION; NOTE: Invacare recommends leaving a full cylinder of oxygen with
HomeFill ™ II Compressor 6 Part No 1100873 LABEL LOCATION DEALER INFORMATION NOTE: Invacare recommends leaving a full cylinder of oxygen with the patient after setting up the HomeFill II compressor. Before leaving a HomeFill II Compressor with a user, the following checklist MUST be completed: ❑ Mak...
Page 7 - HOMEFILL II INFORMATION; HomeFill II is an accessory device to the oxygen concentrator; The HomeFill II compressor is for use with specially
HOMEFILL II INFORMATION HomeFill ™ II Compressor 7 Part No 1100873 HOMEFILL II INFORMATION HomeFill II is an accessory device to the oxygen concentrator that enables the patient to refill custom portable oxygen cylinders for personal use. NOTICE The HomeFill II compressor is for use with specially d...
Page 8 - SECTION 1—IMPORTANT SAFETY INSTRUCTIONS; SECTION 1—IMPORTANT SAFETY; When using the HomeFill II, basic precautions should; TO REDUCE THE RISK OF BURNS,ELECTROCUTION,
SECTION 1—IMPORTANT SAFETY INSTRUCTIONS Part No 1100873 8 HomeFill ™ II Compressor SECTION 1—IMPORTANT SAFETY INSTRUCTIONS WARNING SECTION 1 - IMPORTANT SAFETY INSTRUCTIONS contains important information for the safe operation and use of this product. DO NOT use this product or any available optiona...
Page 11 - Servicing of Double-Insulated Products; CAUTION
SECTION 1—IMPORTANT SAFETY INSTRUCTIONS HomeFill ™ II Compressor 11 Part No 1100873 If any leakage of the oxygen cylinder is detected DO NOT attempt to use the cylinder. Turn the flow selector knob on the regulator to Off. If leakage persists, place the cylinder outdoors and notify your Home Health ...
Page 12 - SECTION 2—INITIAL SETUP; NOTE: Dealers Only - Refer to Dealer Information on page 6 before; Initial Set Up of Compressor; Compressor Initial Setup Checklist; NEVER use near any type of flame or flammable/explosive
SECTION 2—INITIAL SETUP Part No 1100873 12 HomeFill ™ II Compressor SECTION 2—INITIAL SETUP NOTE: Dealers Only - Refer to Dealer Information on page 6 before performing this procedure. Initial Set Up of Compressor Compressor Initial Setup Checklist Before operating the HomeFill II Compressor for the...
Page 13 - Transporting the Compressor; NEVER transport a compressor with a cylinder connected; When transporting the compressor, be careful not to; Installing the Power Cord; Hand Grip
SECTION 2—INITIAL SETUP HomeFill ™ II Compressor 13 Part No 1100873 Transporting the Compressor WARNING NEVER transport a compressor with a cylinder connected to or stored on the compressor, otherwise injury or damage can occur. CAUTION When transporting the compressor, be careful not to bump the co...
Page 14 - Plug the opposite end of the power cord into the wall; Connecting the Compressor to the Concentrator; Insert one end of the interconnect hose into the outlet
SECTION 2—INITIAL SETUP Part No 1100873 14 HomeFill ™ II Compressor 4. Plug the opposite end of the power cord into the wall outlet. FIGURE 2.2 Installing the Power Cord Connecting the Compressor to the Concentrator NOTE: For this procedure, refer to FIGURE 2.3 on page 15. 1. Insert one end of the i...
Page 16 - SECTION 3—CHECKLIST AND CYLINDER INSPECTION; SECTION 3—CHECKLIST AND; ONLY use cylinders that have the Invacare HomeFill II
SECTION 3—CHECKLIST AND CYLINDER INSPECTION Part No 1100873 16 HomeFill ™ II Compressor SECTION 3—CHECKLIST AND CYLINDER INSPECTION Compressor Operation Checklist Each time the HomeFill II Compressor is used to fill a cylinder, complete the following checklist: ❑ Ensure the concentrator has been On ...
Page 17 - Cylinder Prefill Inspection
SECTION 3—CHECKLIST AND CYLINDER INSPECTION HomeFill ™ II Compressor 17 Part No 1100873 FIGURE 3.1 Cylinder Prefill Inspection DO NOT REMOVE THIS PRODUCT LABEL Not for Commercial Resale Invacare Corporation2101 E. Lake Mary Blvd.Sanford, FL 327731-800-832-4707 Part Number 1125090 Rev B - 11/04 OXYGE...
Page 18 - The Hydrostatic Testing Date; DO NOT fill cylinders that have not been tested in the; External Examination
SECTION 3—CHECKLIST AND CYLINDER INSPECTION Part No 1100873 18 HomeFill ™ II Compressor The Hydrostatic Testing Date Aluminum cylinders MUST undergo testing every five years. WARNING DO NOT fill cylinders that have not been tested in the past five years. Otherwise, serious personal injury may result...
Page 20 - REGISTER YOUR PRODUCT!; Complete form and mail.; PRODUCT REGISTRATION FORM
REGISTER YOUR PRODUCT! The benefits of registering: 1. Safeguard your investment. 2. Ensure long term maintenance and servicing of your purchase. 3. Receive updates with product information, maintenance tips, and industrynews. 4. Invacare can contact you or your provider, if servicing is needed on y...
Page 23 - SECTION 4—COMPRESSOR OPERATION; SECTION 4—COMPRESSOR; Connecting the Cylinder to the Compressor; NEVER use tools of any kind to connect/disconnect the
SECTION 4—COMPRESSOR OPERATION HomeFill ™ II Compressor 23 Part No 1100873 SECTION 4—COMPRESSOR OPERATION Connecting/Disconnecting the Cylinder to/from the Compressor Connecting the Cylinder to the Compressor WARNING NEVER use tools of any kind to connect/disconnect the cylinder and the compressor. ...
Page 24 - DO NOT connect the outlet (cannula) connection to the; be able to accept the cylinder fillport. Pushing DOWN; Resetting Connector Fillport; Connector Fillport; GREEN Dots
SECTION 4—COMPRESSOR OPERATION Part No 1100873 24 HomeFill ™ II Compressor CAUTION DO NOT connect the outlet (cannula) connection to the HomeFill II compressor, otherwise the conserving cylinder will not work properly. 4. Momentarily push DOWN on the outer ring (sleeve) of the connector fillport unt...
Page 25 - Pull UP on the outer ring (sleeve) of the connector fillport
SECTION 4—COMPRESSOR OPERATION HomeFill ™ II Compressor 25 Part No 1100873 8. Pull UP on the outer ring (sleeve) of the connector fillport while pushing DOWN on the cylinder/regulator assembly to couple the cylinder fillport into the connector fillport (FIGURE 4.2). NOTE: The cylinder is properly co...
Page 27 - Disconnecting the Cylinder from the Compressor
SECTION 4—COMPRESSOR OPERATION HomeFill ™ II Compressor 27 Part No 1100873 Disconnecting the Cylinder from the Compressor WARNING NEVER use tools of any kind to connect/disconnect the cylinder and the compressor. Otherwise, severe injury and/or damage may occur. NOTE: For this procedure, refer to FI...
Page 28 - The fillport cover on the connector fillport and the; Cylinder Fillport Cover
SECTION 4—COMPRESSOR OPERATION Part No 1100873 28 HomeFill ™ II Compressor 5. When the cylinder fillport is disconnected from the connector fillport, release the outer ring (sleeve) of the connector fillport and use two hands to remove the cylinder from the compressor cradle. WARNING The fillport co...
Page 29 - Turning the Compressor On; The concentrator flow rate to the patient MUST be set at
SECTION 4—COMPRESSOR OPERATION HomeFill ™ II Compressor 29 Part No 1100873 Turning the Compressor On NOTE: For this procedure, refer to FIGURE 4.5 on page 30. 1. Make sure the concentrator is On. Refer to the concentrator Owner’s Manual. CAUTION The concentrator flow rate to the patient MUST be set ...
Page 30 - oxygen level reaches 90%. If light does not go Off within 10
SECTION 4—COMPRESSOR OPERATION Part No 1100873 30 HomeFill ™ II Compressor oxygen level reaches 90%. If light does not go Off within 10 minutes, refer to Troubleshooting/ Cylinder Fill times on page 34.NOTE: If the ATTENTION (RED) light and audible alarm are on. Refer to Troubleshooting/ Cylinder Fi...
Page 31 - Setting the Flow Knob to the Prescribed; Attach the nasal cannula to the outlet fitting of the; As changing the L/min. setting on the flow knob will affect; Outlet Fitting
SECTION 4—COMPRESSOR OPERATION HomeFill ™ II Compressor 31 Part No 1100873 Setting the Flow Knob to the Prescribed Setting NOTE: For this procedure, refer to FIGURE 4.6. 1. Attach the nasal cannula to the outlet fitting of the cylinder. 2. Turn the flow knob to the L/min. setting prescribed by your ...
Page 32 - SECTION 5—INDICATOR LIGHTS
SECTION 5—INDICATOR LIGHTS Part No 1100873 32 HomeFill ™ II Compressor SECTION 5—INDICATOR LIGHTS INDICATOR LIGHT COLOR COMPRESSOR STATUS EFFECT None Compressor is Off O 2 flowing to user if concentrator is on O 2 BELOW NORMAL - YELLOW Compressor is On and warming up (0-3 minutes after power is On) ...
Page 34 - SECTION 6—TROUBLESHOOTING/ CYLINDER FILL TIMES; SECTION 6—TROUBLESHOOTING/; TROUBLESHOOTING
SECTION 6—TROUBLESHOOTING/ CYLINDER FILL TIMES Part No 1100873 34 HomeFill ™ II Compressor SECTION 6—TROUBLESHOOTING/ CYLINDER FILL TIMES TROUBLESHOOTING PROBLEM SOLUTION No indicator lights on when compressor turned on. 1. Turn compressor Off. 2. Check that power cord is properly plugged into compr...
Page 36 - NOTE: All filling times are approximate and may vary on; CYLINDER FILL TIMES
SECTION 6—TROUBLESHOOTING/ CYLINDER FILL TIMES Part No 1100873 36 HomeFill ™ II Compressor NOTE: All filling times are approximate and may vary on environmental conditions. Regulator is On but O 2 is not being delivered 1. Refill cylinder 2. Check that cannula is straight and not pinched. If damaged...
Page 37 - SECTION 7—MAINTENANCE; Push the power switch to the Off (O) position and unplug; DO NOT unplug by pulling on cord. To unplug, grasp the; Filter
SECTION 7—MAINTENANCE HomeFill ™ II Compressor 37 Part No 1100873 SECTION 7—MAINTENANCE Cleaning the Compressor Filter WARNING Push the power switch to the Off (O) position and unplug the compressor before cleaning. DO NOT operate the compressor without the filter installed. CAUTION DO NOT unplug by...
Page 38 - Cabinet; LIMITED WARRANTY
LIMITED WARRANTY Part No 1100873 38 HomeFill ™ II Compressor Cabinet WARNING Push the power switch to the Off (O) position and unplug the compressor before cleaning. To avoid electrical shock, DO NOT remove cabinet. 1. Clean the cabinet with a mild household cleaner and non-abrasive cloth or sponge....