Heavy Duty Cleaning Procedure
For Invacare Continuing Care Group Tubs
WARNING
DO NOT use this product or any available optional equipment without first completely reading and understanding these
instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied
with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a
healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may
occur.
The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant
with a dilution ratio (½ oz. per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of
disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using
any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of
disinfectant to another type, the disinfectant flowmeter must be calibrated before performing this procedure. Refer to the tub owner’s
manual or to the calibration instruction sheet, part number 1154272, for the calibration procedure.
ALWAYS wear rubber gloves, an apron and face shield protection during disinfecting, cleaning and rinsing procedures. In case of
eye or skin contact, follow procedures on disinfectant container.
CAUTION
NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners
will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine
®
or
methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these
types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly.
Before starting the whirlpool pump, the water level must be completely above the whirlpool jets. Otherwise damage to the
motor/pump will result.
Heavy Duty Cleaning Procedure
In
addition
to
disinfecting
your
tub
after
every
use,
you
will
need
to
perform
this
procedure
approximately
once
every
80
‐
150
baths.
1.
Clean
the
entire
surface
of
the
tub
to
remove
visible
tissue
residue
and
fluid.
2.
Rinse
the
inside
surface
of
the
tub
with
the
shower/massage
wand
on
the
spray
setting.
3.
Rotate
the
water
temperature
valve
to
adjust
the
water
temperature
to
approximately
105
o
F.
NOTE:
This
will
maximize
the
cleaning
solution
ʹ
s
ability
to
clean
and
disinfect
the
system.
4.
Close
the
drain.
5.
Make
sure
the
whirlpool
jets
are
open.
6.
Fill
the
tub
one
inch
above
the
highest
whirlpool
jets.
7.
Add
the
Invacare
Heavy
Duty
Cleaner
to
the
water
in
the
tub.
Refer
to
the
chart
for
the
proper
amount.
8.
Spray
pre
‐
mixed
Invacare
Heavy
Duty
Cleaner
on
the
remaining
surfaces.
9.
Press
the
whirlpool
on/off
button
to
turn
on
the
whirlpool
pump
and
let
the
pump
run
for
60
seconds.
10. Turn
off
the
pump
and
allow
the
heavy
duty
cleaner/water
solution
to
remain
in
the
tub
for
10
minutes.
11. During
this
ten
‐
minute
waiting
time,
take
a
long
handled
brush
and
thoroughly
scrub
all
interior
surfaces
of
the
tub.
12. Open
the
drain
to
allow
the
heavy
duty/water
solution
to
drain
from
the
tub.
13. Use
the
shower/massage
wand
on
the
pulse
setting
and
direct
the
spray
into
both
whirlpool
jets
to
back
flush
until
the
water
discharging
from
the
whirlpool
inlet
is
clear.
14. Rinse
the
tub
thoroughly
with
the
shower
wand
on
the
spray
setting.
15. Check
the
tub
for
damage
and
to
ensure
all
surfaces
of
the
tub
are
clean
and
that
no
visible
residue
remains.
If
residue
is
found,
repeat
STEPS
13
and
14.
Maintenance Instructions
SAVE THESE INSTRUCTIONS
Invacare Continuing Care Group
www.invacare-ccg.com
USA
One Invacare Way
Elyria, Ohio USA
44036-2125
Canada
994 Hargrieve Rd.
London Ontario
N6E IP5 Canada
All rights reserved. Trademarks are identified by the symbols ™ and ®. All
trademarks are owned by or licensed to Invacare Corporation unless
otherwise noted.
Betadine is a registered trademark of Purdue Pharma L.P.
© 2008 Invacare Corporation
Part No 1154271
For customer service call: 800-668-2337
Rev A - 04/08
TUB
MODEL
NUMBER
WATER REQUIRED
TO COVER JETS
(GALLONS)
INVACARE
HEAVY DUTY
CLEANER
REQUIRED (OZ)*
2800
10
40
2001
32
128
3700
30
120
3750
30
120
3800
30
120
3600
30
120
3650
48
192
3600XL
48
192
2300
25
100
3300
30
120
4300
35
140
4300HL
35
140
5300
52
208
5300HL
52
208
6300
50
200
6300ADH
50
200
4400SS
48
192
5400SS
50
200
*NOTE:
If
using
non
‐
Invacare
heavy
duty
cleaner,
refer
to
the
instructions
supplied
with
the
cleaner
to
determine
the
proper
amount
required.