Ingersoll Rand PH15-F - Manual
Ingersoll Rand PH15-F – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – OPERATING AND SAFETY PRECAUTIONS
- Page 3 – Page of 8; EXCESSIVE AIR PRESSURE. Can cause pump
- Page 4 – COMMON PARTS
- Page 5 – ASSEMBLY TORQUE REQUIREMENTS; ALL FASTENERS ARE METRIC.; LUBRICATION / SEALANTS
- Page 6 – AIR MOTOR SECTION SERVICE; GENERAL REASSEMBLY NOTES:; PILOT VALVE DISASSEMBLY; MUST FACE EACH OTHER.; AIR MOTOR PARTS LIST
- Page 7 – Apply Lubriplate FML-2 grease to all “O” rings, “U” cups; Figure; MAJOR VALVE; Notch
- Page 8 – TROUBLE SHOOTING; Product discharged from exhaust outlet.; DIMENSIONAL DATA; Figure 4; DIMENSIONS
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276
FAX (800) 892-6276
© 2012
CCN 46750519
www.ingersollrandproducts.com
OPERATOR’S MANUAL
PH15F-XXX-XXX-X
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
RELEASED: 12-14-12
(REV. A)
1.5" DIAPHRAGM PUMP
2:1 RATIO (METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
Figure 1
SERVICE KITS
Refer to Model Description Chart to match the pump mate-
rial options.
637445-XX for Fluid section repair (see page 4). NOTE: This kit
also contains several air motor seals which will need to be
replaced.
637389 for Air Motor Service Kit (see page 6).
637390-7 for Major Air Valve Kit (see page 7).
PUMP DATA
Models . . . . . . . . . . . see Model Description Chart for “-XXX”
Pump Type . . . . . . . Metallic Air Operated Double Diaphragm
Material . . . . . . . . . . see Model Description Chart
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 lbs (39.9 kgs)
Maximum Air Inlet Pressure . . . . . . . 100 p.s.i.g. (6.9 bar)
Maximum Material Inlet Pressure . . 10 p.s.i.g. (0.69 bar)
Maximum Outlet Pressure . . . . . . . . . 200 p.s.i.g. (13.8 bar)
Maximum Flow Rate . . . . . . . . . . . . . . . 63 g.p.m. (238.5 p.m.)
Displacement / Cycle @ 100 p.s.i.g. 0.88 gal. (3.33 lit.)
Maximum Particle Size . . . . . . . . . . . . 1/4” dia. (6.4 mm)
Maximum Temperature Limits (diaphragm / ball / seal
material)
E.P.R. / EPDM . . . . . . . . . . . . . . -60° to 280° F (-51° to 138° C)
Hytrel® . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)
Polypropylene . . . . . . . . . . . . 35° to 175° F (2° to 79° C)
Santoprene® . . . . . . . . . . . . . . -40° to 225° F (-40° to 107° C)
PTFE. . . . . . . . . . . . . . . . . . . . . . 40° to 225° F (4° to 107° C)
Viton® . . . . . . . . . . . . . . . . . . . . -40° to 350° F (-40° to 177° C)
Dimensional Data . . . . . . . . . . . . . . . . . . see page 8
Noise Level @ 70 p.s.i., 54 c.p.m.
. . 75.6 db(A)
Tested with 350-568 muffler assembly installed.
The pump sound pressure levels published here have been updated to
an Equivalent Continuous Sound Level (L
Aeq
) to meet the intent of ANSI
S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.
NOTICE: All possible options are shown in the chart, however, certain
combinations may not be recommended, consult a representative or
the factory if you have questions concerning availability.
MODEL DESCRIPTION CHART
PH15 F - X S P - S X X - X
Air Motor / Air Cap Material
F - Conductive Polypropylene
/ Stainless Steel
Fluid Connection
A - 1 1/2 N.P.T.F.
B - 1 1/2 BSP parallel
F - 1 1/2 ANSI / DIN Flange
Ball Material
A - Santoprene
T - PTFE
C - Hytrel
V - Viton
Fluid Section Service Kit Selection
EXAMPLE: Model #PH15F-ASP-SAA-C
Fluid Section Service Kit # 637445-XX
PH15F - XXX - X X X - X
Ball
Diaphragm
637445 - X X
Fluid Cap & Manifold Material
S - Stainless Steel
Diaphragm Material
A - Santoprene
T - PTFE / Santoprene
C - Hytrel
Seat Material
S - Stainless Steel
Hardware Material
P - Plated Steel
Pump Size
15 - 1.5”
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 of 8 PH15F-XXX-XXX-X (en) WARNING EXCESSIVE AIR PRESSURE. Can cause per- sonal injury, pump damage or property damage. Do not exceed the maximum inlet air pressure as stated on the pump model plate. Be sure material hoses and other components are able to withstand fluid pressures developed by...
PH15F-XXX-XXX-X (en) Page of 8 Hytrel® and Viton® are registered trademarks of the DuPont Company Loctite® and 242® are registered trademarks of Henkel Loctite Corporation Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. ARO® is a regi...
Page 4 of 8 PH15F-XXX-XXX-X (en) PARTS LIST / PH15F-XXX-XXX-X FLUID SECTION 67445-XX Fluid Section Service Kits include: Balls (see Ball Option, refer to -XXX in chart below), Diaphragms (see Diaphragm Option, refer to -XXX in chart below), and items 70, 144 ,175 and 180 (listed below) plus items ...