Ingersoll Rand PE20X-XXX-XXX-XXXX - Manual

Ingersoll Rand PE20X-XXX-XXX-XXXX

Ingersoll Rand PE20X-XXX-XXX-XXXX – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 6 – Without end of stroke feedback, solenoid control can only; figure 1
  • Page 7 – figure 4; LUBRICATION / SEALANTS; “U” cups and mating parts.
  • Page 8 – Set ring may need to be adjusted accordingly.; figure 5
  • Page 9 – NOTE: ALL WIRING MUST COMPLYWITH ALL LOCAL; LEAK DETECTION (DIAPHRAGM fAILURE DETECTOR); figure 8; LEAK DETECTION (DIAPHRAGM fAILURE DETECTOR) - PINOUT DESCRIPTIONS; figure 7
  • Page 10 – GENERAL DESCRIPTION; The ARO diaphragm pump cycle counter provides a closed; CYCLE COUNTER; figure 9
  • Page 12 – OPERATION; The pump may be interfaced with a control device in the; Figure 1
  • Page 13 – PORTED NO MOTOR OPTIONS
Loading the manual

OPERATOR’S MANUAL

PE10X-XXX-XXX-XXXX

PE15X-XXX-XXX-XXXX

PE20X-XXX-XXX-XXXX

PE30X-XXX-XXX-XXXX

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

RELEASED:

3-26-13

(REV. B)

ELECTRONIC INTERfACE

for Diaphragm Pumps

READ THIS MANUAL CAREfULLY BEfORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 495-0276

FAX (800) 892-6276

© 2013

CCN 46750816

www.ingersollrandproducts.com

PUMP DATA

PE10X-XXX-XXX-XXXX is PE series 1” EXP Diaphragm Pumps with

electronic interface

PE15X-XXX-XXX-XXXX is PE series 1- 1/2” EXP Diaphragm Pumps

with electronic interface

PE20X-XXX-XXX-XXXX is PE series 2” EXP Diaphragm Pumps with

electronic interface

PE30X-XXX-XXX-XXXX is PE series 3” EXP Diaphragm Pumps with

electronic interface

GENERAL DESCRIPTION

This manual is supplemental information for the electronic

interface options on the PE series of pumps. For complete

pump installation, disassembly and reassembly, safety infor-

mation, and other general pump information, please refer to

the PD pump manual that was also included with the pump.

This electronic interface includes options for solenoid control,

end of stroke feedback, leak detection (diaphragm failure),

cycle counting on the major valve, and a ported motor with

no major valve for user-supplied control directly to the two

diaphragm air chambers.

Solenoid control allows the cycle rate of the pump to be con-

trolled electronically.

With Solenoid control, when the solenoid is energized, the

pump strokes and dispenses the fluid in one chamber. When

the solenoid is de-energized, the pump strokes in the oppo-

site direction, dispensing the fluid in the other chamber.

By providing continuous ON - OFF signals to the solenoid, the

fluid transfer rate may be increased or decreased remotely.

End of stroke feedback can be used in conjunction with the

solenoid valve to cycle the pump based upon completion of

each stroke.

The leak detection option incorporates an optical fluid sensor

in each air chamber to provide a signal when a diaphragm

has failed and fluid is leaking through the pump.

The cycle counter option provides a closed contact output

each time the pump completes a cycle. This option is not

available combined with solenoid control.

The ported motor with no major valve is provided as an op-

tion for users who want to supply compressed air directly to

each diaphragm and control the operation of the pump with

their own external air controls.

MODEL DESCRIPTION CHART

PEXX X -XXX-XXX -X X X X

Pump Size

10 - 1” EXP Diaphragm Pumps

15 - 1- 1/2” EXP Diaphragm Pumps

20 - 2” EXP Diaphragm Pumps
30 - 3” EXP Diaphragm Pumps

Center Section

A - Aluminium

R - Polypropylene

S - Stainless Steel

Revision Level

Specialty Code 1 (Blank if no Speciality Code)

B - Solenoid 12VDC

D - Solenoid 24VDC

A - Solenoid 120VAC

C - Solenoid 240VAC

G - Solenoid 12VDC ATEX

H - Solenoid 24VDC ATEX

K - Solenoid 220VAC ATEX

N - Solenoid with no coil

P - Ported Motor (no major valve provided)

S - Cycle Sensing on Major Valve

0 - Standard Valve Block ( No Solenoid)

Specialty Code 2 (Blank if no Speciality Code)

F - End of stroke feedback

E - End of stroke feedback + Leak Detection

L - Leak Detection

Special Testing

Testing for special testing options, please contact your

nearest

ARO

Customer Service Representative or Distributor.

0 - No Option

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 6 - Without end of stroke feedback, solenoid control can only; figure 1

PEXXP-XXX-XXX-XXXX (en) Page 6 of 16 SOLENOID GENERAL DESCRIPTION Without end of stroke feedback, solenoid control can only be used to cycle the pump based on timing. The following curves represent the flow rates of a pump based on timed operation of the solenoid at a common operating point of 70 ps...

Page 7 - figure 4; LUBRICATION / SEALANTS; “U” cups and mating parts.

Page 7 of 16 PEXXP-XXX-XXX-XXXX (en) 140 141 200 233 105 107 107 236 135 � 139 138 � 137 � 136 111 419 � 421 420 134 133 429 417 403 415 418 416 407 428 414 413 figure 4  LUBRICATION / SEALANTS   Apply Lubriplate fML-2 grease (94276) to all “O” rings, “U” cups and mating parts. SOLENOID PART LIST...

Page 8 - Set ring may need to be adjusted accordingly.; figure 5

PEXXP-XXX-XXX-XXXX (en) Page 8 of 16 END Of STROKE GENERAL DESCRIPTION With end of stroke feedback from a pressure switch, the solenoid can be used to cycle the pump based on known feed- back that the pump has fully completed each stroke. PRESSURE SWITCH OPERATION A calibration procedure is necessar...

Other Ingersoll Rand Models