Ingersoll Rand PE01X - Manual

Ingersoll Rand PE01X

Ingersoll Rand PE01X – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – MODEL DESCRIPTION CHART; Model Code Explanation
  • Page 3 – OPERATING AND SAFETY PRECAUTIONS
  • Page 4 – OPERATING INSTRUCTIONS; WARNING; EXCESSIVE AIR PRESSURE. Can cause pump; INSTALLATION
  • Page 5 – MATERIAL CODE
  • Page 6 – cups and mating parts.
  • Page 7 – AIR SECTION PARTS
  • Page 8 – “U” cups and mating parts.
  • Page 9 – PE01X OPTION WIRING DIAGRAMS; End of Stroke / Cycle Sensor Pinout, M12 Connector; CABLE ASSEMBLY WIRING COLORS:; End of Stroke / Cycle Sensor Pinout Wiring Diagram (No Connector); BROWN; PNP Output; BLACK; Diaphragm Failure Detector Wiring Diagram; SCHEMATIC; PINOUT FUNCTION; SIGNAL
  • Page 10 – DIMENSIONAL DATA; DIMENSIONS
Loading the manual

OPERATOR’S MANUAL PX01X-XXX-XXX-AXXX

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

RELEASED: 3-7-13

(REV. B)

1/4" DIAPHRAGM PUMP

1:1 RATIO (NON-METALLIC)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 495-0276

FAX (800) 892-6276

© 2013

CCN 80448053

www.ingersollrandproducts.com

Model PD01X

Model PE01X

Figure 1

PUMP DATA

Models

. . . . . . see Model Description Chart on page 2 for

“-XXX” options

Pump Type

. . Non-Metallic Air Operated Double Diaphragm

Material

. . . . . see Model Description Chart

Weight

. . . . . . Polypropylene . . . . . . . . 2 .86 lbs (1 .30 kgs)

PVDF . . . . . . . . . . . . . . . . . 3 .88 lbs (1 .76 kgs)

Acetal . . . . . . . . . . . . . . . . 3 .52 lbs (1 .60 kgs)

Maximum Air Inlet Pressure

. . . . . . . . 125 psig (8 .6 bar)

Minimum Air Inlet Pressure

. . . . . . . . . 10 psig (0 .69 bar)

Maximum Outlet Pressure

. . . . . . . . . . 125 psig (8 .6 bar)

Maximum Flow Rate

. . . . . . . . . . . . . . . . 5 .3 gpm (20 lpm)

Maximum Material Inlet Pressure

. . . . 10 psig (0 .69 bar)

Displacement / Cycle @ 125 p.s.i.g

. . 0 .019 gal / 0 .072 ltrs

Maximum Particle Size

. . . . . . . . . . . . . 1/16” dia .(1 .6 mm)

Maximum Temperature Limits (diaphragm / ball / seat

material)

Acetal . . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)

E .P .R . / EPDM . . . . . . . . . . . . . . -60° to 280° F (-51° to 138° C)

Kynar® PVDF . . . . . . . . . . . . . . 10° to 200° F (-12° to 93° C)

Hytrel® . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)

Neoprene . . . . . . . . . . . . . . . . 0° to 200° F (-18° to 93° C)

Nitrile® . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)

Polypropylene . . . . . . . . . . . . 35° to 175° F (2° to 79° C)

Viton® . . . . . . . . . . . . . . . . . . . . -40° to 350° F (-40° to 177° C)

Santoprene® . . . . . . . . . . . . . . -40° to 225° F (-40° to 107° C)

PTFE . . . . . . . . . . . . . . . . . . . . . . 40° to 225° F (4° to 107° C)

Dimensional Data

. . . . . . . . . . . . . . . . . . . see page 10

Noise Level

@ 70 p .s .i ., 60 c .p .m . . . . . . . 62 .3 db(A)

The pump sound pressure levels published here have been updated to

an Equivalent Continuous Sound Level (L

Aeq

) to meet the intent of ANSI

S1 .13-2005, CAGI-PNEUROP S5 .1 .

Mounting Adapter Plate Optional Accessory Kit (24123879) available .

Please contact your nearest

ARO / Ingersoll Rand

customer service or

distributor for details .

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MODEL DESCRIPTION CHART; Model Code Explanation

Page 2 of 12 PX01X-XXX-XXX-AXXX (en) MODEL DESCRIPTION CHART Model Code Explanation Example: PX01 X - X X X - X X X - A X X X Model Series PD01- Standard PumpPE01- Electronic Interface Center Body Material P - Polypropylene F- Polypropylene with Leak Failure Detection E- Groundable Polypropylene Con...

Page 3 - OPERATING AND SAFETY PRECAUTIONS

PX01X-XXX-XXX-AXXX (en) Page 3 of 12 EXCESSIVE AIR PRESSURE S TATIC SPARK HAZARDOUS MATERIALS HAZARDOUS PRESSURE WARNING EXCESSIVE AIR PRESSURE. Can cause per- sonal injury, pump damage or property damage. y Do not exceed the maximum inlet air pressure as stated on the pump model plate. y Be sure ma...

Page 4 - OPERATING INSTRUCTIONS; WARNING; EXCESSIVE AIR PRESSURE. Can cause pump; INSTALLATION

Page 4 of 12 PX01X-XXX-XXX-AXXX (en) y Kynar® is a registered trademark of the Arkema Inc . y Loctite® and 242 are registered trademarks of the Henkel Loctite Corporation y y ARO® is a registered trademark of Ingersoll-Rand Company y Santoprene® is a registered trademark of Monsanto Company, license...

Other Ingersoll Rand Models