Ingersoll Rand PD01X - Manual
Ingersoll Rand PD01X – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – MODEL DESCRIPTION CHART; Model Code Explanation
- Page 3 – OPERATING AND SAFETY PRECAUTIONS
- Page 4 – OPERATING INSTRUCTIONS; WARNING; EXCESSIVE AIR PRESSURE. Can cause pump; INSTALLATION
- Page 5 – MATERIAL CODE
- Page 6 – cups and mating parts.
- Page 7 – AIR SECTION PARTS
- Page 8 – “U” cups and mating parts.
- Page 9 – PE01X OPTION WIRING DIAGRAMS; End of Stroke / Cycle Sensor Pinout, M12 Connector; CABLE ASSEMBLY WIRING COLORS:; End of Stroke / Cycle Sensor Pinout Wiring Diagram (No Connector); BROWN; PNP Output; BLACK; Diaphragm Failure Detector Wiring Diagram; SCHEMATIC; PINOUT FUNCTION; SIGNAL
- Page 10 – DIMENSIONAL DATA; DIMENSIONS
OPERATOR’S MANUAL PX01X-XXX-XXX-AXXX
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
RELEASED: 3-7-13
(REV. B)
1/4" DIAPHRAGM PUMP
1:1 RATIO (NON-METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276
FAX (800) 892-6276
© 2013
CCN 80448053
www.ingersollrandproducts.com
Model PD01X
Model PE01X
Figure 1
PUMP DATA
Models
. . . . . . see Model Description Chart on page 2 for
“-XXX” options
Pump Type
. . Non-Metallic Air Operated Double Diaphragm
Material
. . . . . see Model Description Chart
Weight
. . . . . . Polypropylene . . . . . . . . 2 .86 lbs (1 .30 kgs)
PVDF . . . . . . . . . . . . . . . . . 3 .88 lbs (1 .76 kgs)
Acetal . . . . . . . . . . . . . . . . 3 .52 lbs (1 .60 kgs)
Maximum Air Inlet Pressure
. . . . . . . . 125 psig (8 .6 bar)
Minimum Air Inlet Pressure
. . . . . . . . . 10 psig (0 .69 bar)
Maximum Outlet Pressure
. . . . . . . . . . 125 psig (8 .6 bar)
Maximum Flow Rate
. . . . . . . . . . . . . . . . 5 .3 gpm (20 lpm)
Maximum Material Inlet Pressure
. . . . 10 psig (0 .69 bar)
Displacement / Cycle @ 125 p.s.i.g
. . 0 .019 gal / 0 .072 ltrs
Maximum Particle Size
. . . . . . . . . . . . . 1/16” dia .(1 .6 mm)
Maximum Temperature Limits (diaphragm / ball / seat
material)
Acetal . . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)
E .P .R . / EPDM . . . . . . . . . . . . . . -60° to 280° F (-51° to 138° C)
Kynar® PVDF . . . . . . . . . . . . . . 10° to 200° F (-12° to 93° C)
Hytrel® . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)
Neoprene . . . . . . . . . . . . . . . . 0° to 200° F (-18° to 93° C)
Nitrile® . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)
Polypropylene . . . . . . . . . . . . 35° to 175° F (2° to 79° C)
Viton® . . . . . . . . . . . . . . . . . . . . -40° to 350° F (-40° to 177° C)
Santoprene® . . . . . . . . . . . . . . -40° to 225° F (-40° to 107° C)
PTFE . . . . . . . . . . . . . . . . . . . . . . 40° to 225° F (4° to 107° C)
Dimensional Data
. . . . . . . . . . . . . . . . . . . see page 10
Noise Level
@ 70 p .s .i ., 60 c .p .m . . . . . . . 62 .3 db(A)
The pump sound pressure levels published here have been updated to
an Equivalent Continuous Sound Level (L
Aeq
) to meet the intent of ANSI
S1 .13-2005, CAGI-PNEUROP S5 .1 .
Mounting Adapter Plate Optional Accessory Kit (24123879) available .
Please contact your nearest
ARO / Ingersoll Rand
customer service or
distributor for details .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 of 12 PX01X-XXX-XXX-AXXX (en) MODEL DESCRIPTION CHART Model Code Explanation Example: PX01 X - X X X - X X X - A X X X Model Series PD01- Standard PumpPE01- Electronic Interface Center Body Material P - Polypropylene F- Polypropylene with Leak Failure Detection E- Groundable Polypropylene Con...
PX01X-XXX-XXX-AXXX (en) Page 3 of 12 EXCESSIVE AIR PRESSURE S TATIC SPARK HAZARDOUS MATERIALS HAZARDOUS PRESSURE WARNING EXCESSIVE AIR PRESSURE. Can cause per- sonal injury, pump damage or property damage. y Do not exceed the maximum inlet air pressure as stated on the pump model plate. y Be sure ma...
Page 4 of 12 PX01X-XXX-XXX-AXXX (en) y Kynar® is a registered trademark of the Arkema Inc . y Loctite® and 242 are registered trademarks of the Henkel Loctite Corporation y y ARO® is a registered trademark of Ingersoll-Rand Company y Santoprene® is a registered trademark of Monsanto Company, license...