DIAPHRAGM FAILURE DETECTOR

(INTRINSICALLY SAFE COMPONENTS)

OPERATOR’S MANUAL

67237

RELEASED:

5-31-01

REVISED:

4-13-10

(REV. D)

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

(for 1-1/2”, 2” and 3” Metallic Diaphragm Pumps with Cast Iron or Stainless Steel center bodies)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SENSOR DATA

Protection

The components meet the re-

. . . . . . . . . . . . . . . . . . .

quirements for Class 1, Divi-

sion II, Group C environment.

Voltage

30 VDC max.

. . . . . . . . . . . . . . . . . . . . .

Sensor Type

Electro-Optic

. . . . . . . . . . . . . . . . .

Sensor Material

Polysulfone

. . . . . . . . . . . . . . .

GENERAL DESCRIPTION

An Aro diaphragm pump equiped with the Aro Diaphragm Failure De-

tector warns of a diaphragm failure by sensing the presence of liquid in

the air chamber of the pump. This system uses a liquid sensor in each of

the two air chambers.

OPERATING INSTRUCTIONS

1. Supply voltage for the components can be through the 95087 cable

or through the 95088 adapter (see pinout information on page 2).

2. The cable can be connected to operate an output device as re-

quired (valve, buzzer, light, etc.).

3. To clean the sensors, disconnect the 96270-1 sensors from the

95088 adapter. Unthread the sensors from the air caps. Clean the

prism of the sensors with a mild detergent or water.

WARNING:

Chlorinated hydrocarbons MUST NOT BE USED for cleaning.

See note in 5 below.

4. To reassemble, apply PTFE tape or #80725 Permatex to the

threads of each sensor and thread to the air cap. NOTE: Torque the

sensors to NO MORE THAN 120 in. lbs (13.56 Nm). Reconnect the

sensors to the 95088 adapter.

5. Note: Clean the sensors every 1,000,000 cycles or every 3 months

of use.

96270-1 Sensor (2)

95088 Adapter

95087 Cable

10 m (32.8 ft)

INSTALLATION AND WARNINGS

NOTE: The power supply cable is not furnished with the unit and must

be supplied by the customer.

ALL WIRING MUST COMPLY WITH ALL LOCAL AND / OR NATION-

AL ELECTRICAL CODES.

S

Electrical codes that apply must be strictly adhered to; failure to do

so may lead to shock hazard or serious injury.

S

Some local electrical codes may require the installation of rigid con-

duit.

S

The diaphragm failure detector components must be installed by a

qualified electrician in compliance with all national, state and local

codes and regulations to reduce the risk of electrical shock or other

serious injury during installation and operation.

S

ARO is not responsible for accidents resulting from improper instal-

lation of components or hardware.

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 276-4658 FAX (800) 266-7016

© 2010

CCN 99856692

www.ingersollrandproducts.com