DIAPHRAGM FAILURE DETECTOR
(INTRINSICALLY SAFE COMPONENTS)
OPERATOR’S MANUAL
67237
RELEASED:
5-31-01
REVISED:
4-13-10
(REV. D)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
(for 1-1/2”, 2” and 3” Metallic Diaphragm Pumps with Cast Iron or Stainless Steel center bodies)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SENSOR DATA
Protection
The components meet the re-
. . . . . . . . . . . . . . . . . . .
quirements for Class 1, Divi-
sion II, Group C environment.
Voltage
30 VDC max.
. . . . . . . . . . . . . . . . . . . . .
Sensor Type
Electro-Optic
. . . . . . . . . . . . . . . . .
Sensor Material
Polysulfone
. . . . . . . . . . . . . . .
GENERAL DESCRIPTION
An Aro diaphragm pump equiped with the Aro Diaphragm Failure De-
tector warns of a diaphragm failure by sensing the presence of liquid in
the air chamber of the pump. This system uses a liquid sensor in each of
the two air chambers.
OPERATING INSTRUCTIONS
1. Supply voltage for the components can be through the 95087 cable
or through the 95088 adapter (see pinout information on page 2).
2. The cable can be connected to operate an output device as re-
quired (valve, buzzer, light, etc.).
3. To clean the sensors, disconnect the 96270-1 sensors from the
95088 adapter. Unthread the sensors from the air caps. Clean the
prism of the sensors with a mild detergent or water.
WARNING:
Chlorinated hydrocarbons MUST NOT BE USED for cleaning.
See note in 5 below.
4. To reassemble, apply PTFE tape or #80725 Permatex to the
threads of each sensor and thread to the air cap. NOTE: Torque the
sensors to NO MORE THAN 120 in. lbs (13.56 Nm). Reconnect the
sensors to the 95088 adapter.
5. Note: Clean the sensors every 1,000,000 cycles or every 3 months
of use.
96270-1 Sensor (2)
95088 Adapter
95087 Cable
10 m (32.8 ft)
INSTALLATION AND WARNINGS
NOTE: The power supply cable is not furnished with the unit and must
be supplied by the customer.
ALL WIRING MUST COMPLY WITH ALL LOCAL AND / OR NATION-
AL ELECTRICAL CODES.
S
Electrical codes that apply must be strictly adhered to; failure to do
so may lead to shock hazard or serious injury.
S
Some local electrical codes may require the installation of rigid con-
duit.
S
The diaphragm failure detector components must be installed by a
qualified electrician in compliance with all national, state and local
codes and regulations to reduce the risk of electrical shock or other
serious injury during installation and operation.
S
ARO is not responsible for accidents resulting from improper instal-
lation of components or hardware.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 276-4658 FAX (800) 266-7016
© 2010
CCN 99856692
www.ingersollrandproducts.com