Ingersoll Rand 67314-B - Manual
Ingersoll Rand 67314-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Do not use; SERVICE; If the pump will not cycle or will not deliver material.; Item
- Page 3 – Figure 2
- Page 4 – DISASSEMBLY; Carefully remove the parts, inspect parts; REASSEMBLY; the fl anges are facing each other.
Never service or disassemble the unit or
unit components without relieving hydraulic system
pressure first. The high pressures involved could
cause serious injury.
NOTE: If this pump was purchased separately (not part
of a system), consult your sales representative for com-
patible dispensing accessories which will best match the
application. All accessories must be able to withstand the
maximum pressure developed by the pump.
A replacement warning label is available upon request,
pn \ 94576.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 276-4658 FAX (800) 266-7016
© 2010
CCN 15267008
A
B
OPERATOR’S MANUAL
67314-B
INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING
RELEASED:
11-10-06
REVISED:
5
-
17
-
10
(REV. 0
3
)
67314-B
HYDRAULIC POWER MOTOR
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SERVICE KITS
Use only genuine ARO® replacement parts to assure compat-
ible pressure rating and longest service life.
637450 pump repair kit, includes the necessary soft parts for
normal service of the entire pump.
SPECIFICATIONS
Models
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67314-B
Type
. . . . . . . . . . . . . . . . . . . . Hydraulic Operated Power Motor
Motor Size
. . . . . . . . . . . . . . . . . . . . . . . . . . 4.125 sq.” (26.6 sq. cm)
Stroke
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6” (152 mm)
Hydraulic Inlet
(female) . . . . . . . . . . . . . 1/2 - 14 N.P.T.F. - 2
Hydraulic Outlet
(female) . . . . . . . . . . . 3/4 - 14 N.P.S.M.
Pump Construction
. . . . . . . . . . . . . . . . . Carbon Steel
Dimension “A”
. . . . . . . . . . . . . . . . . . . . . . 20-13/32” (518.2 mm)
Dimension “B”
. . . . . . . . . . . . . . . . . . . . . . 15-11/16” (397.8 mm)
“C” Weep Hole
. . . . . . . . . . . . . . . . . . . . . . 1/8 - 27 N.P.T.F. - 1
Motor Diameter
. . . . . . . . . . . . . . . . . . . . . 8” (203.2 mm)
Maximum Temperature Limits
. . . . . . 130° F (54° C)
Mounting Bracket available
. . . . . . . . 95933
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37.75 lbs (17.1 kgs)
PERFORMANCE
Inlet Pressure Range
. . . . . . . . 65 - 2000 p.s.i. (4.5 - 137.9 bar)
Required H-power @ 50 c.p.m.
. . . . . . 3.2 @ 1200 (82.8 bar)
Hydraulic fl ow required @ 50 c.p.m.
11 g.p.m. (41.6 l.p.m.)
Maximum Thrust generated
. . . . . . . . 8250 lbs
Maximum recommended cycles / minute
. . . . . . . . . 50
Noise Level
. . . . . . . . . . . . . . . . . . . . . . . . . N/A
GENERAL DESCRIPTION
The 4.125 square inch hydraulic motor is a general purpose
power unit and is used on many ARO industrial 2-ball, 4-ball
and chop-check pumps. It utilizes tie rod type construction
for serviceability and connects to the various lower pump
ends by tie rods.
Due to frictional losses in the system, a greater horsepower
is required to run the motor. Power supplies generating less
than shown as required in the Performance Specifications
above will work with the motor but at a reduced pressure or
cycle rate.
Figure 1
OPERATING AND SAFETY PRECAUTIONS
WARNING
READ THE GENERAL INFORMATION MAN-
UAL INCLUDED FOR ADDITIONAL OPERATING AND
SAFETY PRECAUTIONS AND OTHER IMPORTANT IN-
FORMATION.
WARNING
EXCESSIVE MATERIAL PRESSURE. Can cause
equipment failure resulting in severe injury or prop-
erty damage. Do not exceed the maximum material
pressure of any component in the system.
WARNING
A pressure relief valve must be used to pre-
vent over-pressurization of the system and possible
component rupture.
WARNING
Excessive hydraulic oil temperature can
cause fi re. The unit is rated for operation up to 130° F
(54° C). Be sure return lines are sized larger than sup-
ply lines and similarly pressure rated.
WARNING
4.125 SQ.” MOTOR
65 - 2000 P.S.I. RANGE
Hydraulic Outlet
Hydraulic Inlet
C
www.ingersollrandproducts.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
INSTALLATION Use only flexible tubing for inlet and outlet porting to hy-draulic source to prevent wear of components.Be sure return lines are sized larger than supply lines and similarly pressure rated.Inspect the system hoses frequently for wear or damage and, if necessar y, replace them immediate...
PARTS LIST / 67314-B 67314-B (en) Page 3 of 4 ) TORQUE REQUIREMENTS ( NOTE: DO NOT OVERTIGHTEN FASTENERS. (3a, 3b) 90 - 110 in. lbs (10.2 - 12.4 Nm).(14) 100 - 120 ft lbs (135.6 - 162.7 Nm).(25) 100 - 120 ft lbs (135.6 - 162.7 Nm).(37) 44 - 56 ft lbs (59.7 - 75.9 Nm). LUBRICATION / SEALANTS Apply ...
DISASSEMBLY All threads are right hand. Refer to fi gure 2, page 3. These procedures are for the installation of repair kit parts. Disconnect power supply and relieve all system pressure prior to servicing. Carefully remove the parts, inspect parts for damage, nicks or excessive wear and determine i...