Ingersoll Rand 651747-X-B - Manual
Ingersoll Rand 651747-X-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
E
2001
D
PRINTED IN U.S.A.
&
(419) 636-4242
D
FAX (419) 633-1674
INGERSOLL-RAND COMPANY
P.O. BOX 151
D
ONE ARO CENTER
D
BRYAN, OHIO 43506Ć0151
OPERATOR’S MANUAL
651747-X-B
RELEASED:
6-28-92
REVISED:
7-16-01
(REV. G)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
STAINLESS STEEL FLUID HEATER
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
FLUID HEATER DATA
Models
651747ĆXĆB
. . . . . . . . . . . . . . . . . . . . . . . . .
Wetted Parts Material
Stainless Steel
. . . . . . . . . . . . . .
Volts AC
651747Ć1ĆB
120
. . . . . . . . . . . .
651747Ć2ĆB
230 / 240
. . . . . . . . . . . .
651747Ć3ĆB
415 / 440
. . . . . . . . . . . .
Amperes
651747Ć1ĆB
16.6
. . . . . . . . . . . .
651747Ć2ĆB
8.3
. . . . . . . . . . . .
651747Ć3ĆB
4.5
. . . . . . . . . . . .
Watts
2000
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Accuracy
±
3Ć1/2
_
F (1.9
_
C)
. . . . . . . . . . . . . . . . . . . . . . . .
Temperature Rise Above Ambient
100
_
F (38
_
C)
. . . . .
Recovery Rate per Hour
15 gallons (56.8 liters)
. . . . . . . . . . . .
Maximum Working Pressure
5000 p.s.i. (35 MPa)
. . . . . . . . .
Maximum Temperature Range
60 Ć 2 50
_
F (16 Ć 12 1
_
C)
. . . . . . .
Surface Temperature Code
T3 (392
_
F / 2 00
_
C)
. . . . . . . . . .
Fluid Passage Diameter
0.370" (9.4 mm)
. . . . . . . . . . . .
Fluid Passage Length
91.7" (232.9 cm)
. . . . . . . . . . . . . .
Fluid Passage Volume
9.86 in.
3
(0.162lit.)
. . . . . . . . . . . . . .
Inlet / Outlet Port Size (female)
1/2Ć 14 N.P.T.F. Ć 1
. . . . . . .
Weight
18 lbs (8.2kg)
. . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL DESCRIPTION
The Aro stainless steel fluid heater models are wired for 120, 230 / 240
and 415 / 440 volt AC applications. The heating element is a 2000 watt
cartridge type and is thermostatically controlled. The wiring, heating
element and thermostat are protected by a preset heat limiter.
The thermostat is adjustable up to 250
_
F (121
_
C). The heater is off
when the thermostat knob is turned counterclockwise as far as posĆ
sible. The heater will not switch on until the knob is rotated to at least
ambient room temperature.
Fluid heaters have been tested in a water solution. Some of this fluid
may be left within the heater, therefore flush out this fluid with a solvent
compatible with the material to be pumped.
•
This unit utilizes an explosionĆproof electrical section and internally
spiraling material section. The material enters the base under line
pressure from the pump and is heated and delivered thru to the maĆ
terial outlet at the top.
•
This unit is CSA certified for Class I, Division 1, Group D, HazardĆ
ous Locations, Temperature Code (identification number) T3.
•
Two or more paint heaters may be coupled together by plumbing
the material outlet of the first heater to the material inlet of the next,
etc. However, the distance of piping run between the units should
be limited to no more than three feet (see figure 4, page 4).
TYPICAL INSTALLATION
The heater inlet and outlet should be plumbed (up flow) as shown (see
figure 4, page 4), to minimize chances of trapped air inside the heater. If
the inlet and outlet are reversed (down flow), the temperature rise will
be different.
DIMENSIONAL DATA
651747ĆXĆB FLUID HEATER
FIGURE 1
16Ć1/16"
(408.0 mm)
4Ć3/16"
(105.6 mm)
8Ć13/16"
(223.8 mm)
3Ć3/4"
(95.3 mm)
7Ć1/2"
(190.5 mm)
4Ć3/4"
(120.7 mm)
7/8"
(22.2 mm)
1/2 Ć 14 N.P.T.F.
1/2 Ć 14 N.P.T.F.
(Outlet)
1/2 Ć 14 N.P.T.F.
(Inlet)
Mounting holes
(hidden)
Thermometer - Do not overĆ
tighten. For orientation only.
R
OPERATING PRECAUTIONS
•
Heed all warnings.
WARNING
Do not exceed 5000 p.s.i. (35 MPa) maximum.
WARNING
HIGH PRESSURE DEVICE. Improper usage of
this equipment could result in serious injury. The possibility of
injection into the flesh is a potential hazard. Never allow any
part of the human body to come in front of, or in direct contact
with, the material outlet. An injection injury can be serious. If
injection should occur, contact a qualified physician for immeĆ
diate treatment.
CAUTION
Electrical supply power to the heater must be off
during flushing operation.
CAUTION
Use only genuine Aro replacement parts to asĆ
sure compatible pressure rating and longest service life.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.