Ingersoll Rand 651747-X-B - Manual

Ingersoll Rand 651747-X-B

Ingersoll Rand 651747-X-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4
Loading the manual

E

2001

D

PRINTED IN U.S.A.

&

(419) 636-4242

D

FAX (419) 633-1674

INGERSOLL-RAND COMPANY

P.O. BOX 151

D

ONE ARO CENTER

D

BRYAN, OHIO 43506Ć0151

OPERATOR’S MANUAL

651747-X-B

RELEASED:

6-28-92

REVISED:

7-16-01

(REV. G)

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

STAINLESS STEEL FLUID HEATER

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

FLUID HEATER DATA

Models

651747ĆXĆB

. . . . . . . . . . . . . . . . . . . . . . . . .

Wetted Parts Material

Stainless Steel

. . . . . . . . . . . . . .

Volts AC

651747Ć1ĆB

120

. . . . . . . . . . . .

651747Ć2ĆB

230 / 240

. . . . . . . . . . . .

651747Ć3ĆB

415 / 440

. . . . . . . . . . . .

Amperes

651747Ć1ĆB

16.6

. . . . . . . . . . . .

651747Ć2ĆB

8.3

. . . . . . . . . . . .

651747Ć3ĆB

4.5

. . . . . . . . . . . .

Watts

2000

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Accuracy

±

3Ć1/2

_

F (1.9

_

C)

. . . . . . . . . . . . . . . . . . . . . . . .

Temperature Rise Above Ambient

100

_

F (38

_

C)

. . . . .

Recovery Rate per Hour

15 gallons (56.8 liters)

. . . . . . . . . . . .

Maximum Working Pressure

5000 p.s.i. (35 MPa)

. . . . . . . . .

Maximum Temperature Range

60 Ć 2 50

_

F (16 Ć 12 1

_

C)

. . . . . . .

Surface Temperature Code

T3 (392

_

F / 2 00

_

C)

. . . . . . . . . .

Fluid Passage Diameter

0.370" (9.4 mm)

. . . . . . . . . . . .

Fluid Passage Length

91.7" (232.9 cm)

. . . . . . . . . . . . . .

Fluid Passage Volume

9.86 in.

3

(0.162lit.)

. . . . . . . . . . . . . .

Inlet / Outlet Port Size (female)

1/2Ć 14 N.P.T.F. Ć 1

. . . . . . .

Weight

18 lbs (8.2kg)

. . . . . . . . . . . . . . . . . . . . . . . . . .

GENERAL DESCRIPTION

The Aro stainless steel fluid heater models are wired for 120, 230 / 240

and 415 / 440 volt AC applications. The heating element is a 2000 watt

cartridge type and is thermostatically controlled. The wiring, heating

element and thermostat are protected by a preset heat limiter.

The thermostat is adjustable up to 250

_

F (121

_

C). The heater is off

when the thermostat knob is turned counterclockwise as far as posĆ

sible. The heater will not switch on until the knob is rotated to at least

ambient room temperature.

Fluid heaters have been tested in a water solution. Some of this fluid

may be left within the heater, therefore flush out this fluid with a solvent

compatible with the material to be pumped.

This unit utilizes an explosionĆproof electrical section and internally

spiraling material section. The material enters the base under line

pressure from the pump and is heated and delivered thru to the maĆ

terial outlet at the top.

This unit is CSA certified for Class I, Division 1, Group D, HazardĆ

ous Locations, Temperature Code (identification number) T3.

Two or more paint heaters may be coupled together by plumbing

the material outlet of the first heater to the material inlet of the next,

etc. However, the distance of piping run between the units should

be limited to no more than three feet (see figure 4, page 4).

TYPICAL INSTALLATION

The heater inlet and outlet should be plumbed (up flow) as shown (see

figure 4, page 4), to minimize chances of trapped air inside the heater. If

the inlet and outlet are reversed (down flow), the temperature rise will

be different.

DIMENSIONAL DATA

651747ĆXĆB FLUID HEATER

FIGURE 1

16Ć1/16"

(408.0 mm)

4Ć3/16"

(105.6 mm)

8Ć13/16"

(223.8 mm)

3Ć3/4"

(95.3 mm)

7Ć1/2"

(190.5 mm)

4Ć3/4"

(120.7 mm)

7/8"

(22.2 mm)

1/2 Ć 14 N.P.T.F.

1/2 Ć 14 N.P.T.F.

(Outlet)

1/2 Ć 14 N.P.T.F.

(Inlet)

Mounting holes

(hidden)

Thermometer - Do not overĆ

tighten. For orientation only.

R

OPERATING PRECAUTIONS

Heed all warnings.

WARNING

Do not exceed 5000 p.s.i. (35 MPa) maximum.

WARNING

HIGH PRESSURE DEVICE. Improper usage of

this equipment could result in serious injury. The possibility of

injection into the flesh is a potential hazard. Never allow any

part of the human body to come in front of, or in direct contact

with, the material outlet. An injection injury can be serious. If

injection should occur, contact a qualified physician for immeĆ

diate treatment.

CAUTION

Electrical supply power to the heater must be off

during flushing operation.

CAUTION

Use only genuine Aro replacement parts to asĆ

sure compatible pressure rating and longest service life.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.