Ingersoll Rand 650636-X-C - Manual
Ingersoll Rand 650636-X-C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
OPERATOR’S MANUAL
650636 -- X--C
RELEASED: 11--15--96
REVISED:
6--4--10
(REV.
02)
FOUR BALL PUMP SERIES
6” AIR MOTOR
3:1 RATIO
6” STROKE
INCLUDE MANUALS: 6696X--X LOWER PUMP END (PN 97999--051) &
S--632 GENERAL INFORMATION MANUAL (PN 97999--624)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, TROUBLESHOOTING
650636 -- X43--C
400 SERIES STAINLESS STEEL
SERVICE KITS
•
Use only genuine ARO
R
replacement parts to assure compatible
pressure rating and longest service life.
•
61355 for repair of Air Motor section.
Service Note: The Air Motor Service/Parts Manual is not shipped
with the pump but it is included with each Service Kit. If this Service/
Parts Information is needed, request the Air Motor Operator’s Manu-
al from ARO. (Manual 6564X--X, PN 97999--174).
•
637240- X43 for repair of Lower Pump section.
Refer to the chart on page 2 for description of --X43 options.
SPECIFICATIONS
Model Series
(Refer to option chart)
650636--X43--C
. .
Type
Air Operated, Four Ball
. . . . . . . . . . . . . . . . . . . .
Ratio
3:1
. . . . . . . . . . . . . . . . . . . .
Air Motor
65665--B
. . . . . . . . . . . . . . . . .
Motor Repair Kit
61355
. . . . . . . . . .
Motor Diameter
6” (15.2 cm)
. . . . . . . . . . .
Stroke
6’’
. . . . . . . . . . . . . . . . . .
Air Inlet
1/2’’ -- 14 NPTF--1(f)
. . . . . . . . . . . . . . . . .
Air Exhaust
1--1/4’’, 11--1/2 NPTF--1(f)
. . . . . . . . . . . . . .
Lower Pump End Series
66961--X43
. . . . .
Lower Pump Repair Kit
637240--X43
. . . . .
Material Outlet
3/4” NPTF--1(f)
. . . . . . . . . . .
PERFORMANCE
Air Inlet Pressure Range
30 -- 150 PSI (2 -- 10.3 bar)
. . . . .
Fluid Pressure Range
90 -- 450 PSI (6.2 -- 31.0 bar)
. . . . . . .
Max. Rec’d Cycles / Minute
78
. . .
Displacement In
3
Per Cycle
113
. . .
Volume/Cycle
62.6 oz. (1851 ml)
. . . . . . . . . . . . .
Cycles Per Gallon
2.0
. . . . . . . . . .
Flow @ 60 Cycles / Minute
29.35 GPM (111.1 lpm)
. . . .
Noise Level @ 60 Psi - 40 Cpm
84.8 db(A)
*
*
The pump sound pressure level has been updated to an Equivalent Continuous Sound
Level (L
Aeq
) to meet the intent of ANSI S1. 13--1971, CAGI--PNEUROP S5.1 using four
microphone locations.
PUMP DATA
Air Motor
65665--B
(See Manual 6564X--X)
FIGURE 1
Material Outlet
3/4’’ NPTF--1(f)
75
_
FROM AIR EXHAUST
Lower Pump
66961 -- X43
(See Manual 6696X --X)
Air Inlet
1/2--14 NPTF--1(f)
(Not Shown)
Spacer Section
14- 21/32
(372 mm)
Accessories Available: 91790 Silencer, 66101 Wall Bracket.
NUT Y85--29--N (3)
WASHER Y14--625 (3)
SPACER ROD 93232--1 (2)
CONNECTOR
See Figure 2
MODEL 650636- X43- C
17- 25/32
(452 mm)
38- 5/8
(981 mm)
SPRING 94457
SPACER ROD 93232--2
IMPORTANT
This is one of the four documents which support the pump.
Replacement copies of these forms are available upon request.
=
650636--X--C MODEL OPERATOR’S MANUAL
-
GENERAL INFORMATION -- INDUSTRIAL PISTON PUMPS
-
6696X--X LOWER PUMP END OPERATOR’S MANUAL
-
6564X--X AIR MOTOR OPERATOR’S MANUAL
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276
FAX
(800) 892-6276
© 2010
www.ingersollrandproducts.com
CCN 99711749
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.