Ingersoll Rand 650435 - Manual

Ingersoll Rand 650435

Ingersoll Rand 650435 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

OPERATOR’S MANUAL

650435 -- X--C

RELEASED: 11--15--96

REVISED:

6--7--10

(REV.

02)

FOUR BALL PUMP SERIES

4--1/4” AIR MOTOR

2:1 RATIO

6” STROKE

INCLUDE MANUALS: 6695X--X LOWER PUMP END (PN 97999--002) &

S--632 GENERAL INFORMATION MANUAL (PN 97999--624)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, TROUBLESHOOTING

650435 -- X46--C

300 SERIES STAINLESS STEEL

SERVICE KITS

Use only genuine ARO

R

replacement parts to assure compatible

pressure rating and longest service life.

61268 for repair of Air Motor section.

Service Note: The Air Motor Service/Parts Manual is not shipped

with the pump but it is included with each Service Kit. If this Service/

Parts Information is needed, request the Air Motor Operator’s Manu-

al from ARO. (Manual 6544X--X, PN 97999--064).

637230- X43 for repair of Lower Pump section.

Refer to the chart on page 2 for description of --X43 options.

SPECIFICATIONS

Model Series

(Refer to option chart)

650435--X46--C

. .

Type

Air Operated, Four Ball

. . . . . . . . . . . . . . . . . . . .

Ratio

2:1

. . . . . . . . . . . . . . . . . . . .

Air Motor

65465--B

. . . . . . . . . . . . . . . . .

Motor Repair Kit

61268

. . . . . . . . . .

Motor Diameter

4--1/4” (10.8 cm)

. . . . . . . . . . .

Stroke

6’’

. . . . . . . . . . . . . . . . . .

Air Inlet

1/2’’ -- 14 NPTF--1(f)

. . . . . . . . . . . . . . . . .

Air Exhaust

1--1/4’’, 11--1/2 NPTF--1(f)

. . . . . . . . . . . . . .

Lower Pump End Series

66952--X46

. . . . .

Lower Pump Repair Kit

637230--X46

. . . . .

Material Outlet

3/4” NPTF--1(f)

. . . . . . . . . . .

PERFORMANCE

Air Inlet Pressure Range

30 -- 150 PSI (2 -- 10.3 bar)

. . . . .

Fluid Pressure Range

60 -- 300 PSI (4.1 -- 20.7 bar)

. . . . . . .

Max. Rec’d Cycles / Minute

70

. . .

Displacement In

3

Per Cycle

82

. . .

Volume/Cycle

45.4 oz. (1343 ml)

. . . . . . . . . . . . .

Cycles Per Gallon

2.8

. . . . . . . . . .

Flow @ 60 Cycles / Minute

21.3 GPM (80.6 lpm)

. . . .

Noise Level @ 60 Psi - 40 Cpm

81.8 db(A)

*

*

The pump sound pressure level has been updated to an Equivalent Continuous Sound

Level (L

Aeq

) to meet the intent of ANSI S1. 13--1971, CAGI--PNEUROP S5.1 using four

microphone locations.

PUMP DATA

Air Motor

65465--B

(See Manual 6544X--X)

FIGURE 1

Material Outlet

3/4’’ NPTF--1(f)

75

_

FROM AIR EXHAUST

Lower Pump

66952 -- X46

(See Manual 6695X --X)

Air Inlet

1/2--14 NPTF--1(f)

(Not Shown)

Spacer Section

14- 21/32

(372 mm)

Accessories Available: 91790 Silencer, 66101 Wall Bracket.

NUT Y85--29--N (3)

WASHER Y14--625 (3)

SPACER ROD 93232--1 (2)

CONNECTOR

See Figure 2

MODEL 650435- X46- C

17- 25/32

(452 mm)

38- 5/8

(981 mm)

SPRING 94457

SPACER ROD 93232--2

IMPORTANT

This is one of the four documents which support the pump.

Replacement copies of these forms are available upon request.

=

650435--X--C MODEL OPERATOR’S MANUAL

-

GENERAL INFORMATION -- INDUSTRIAL PISTON PUMPS

-

6695X--X LOWER PUMP END OPERATOR’S MANUAL

-

6544X--X AIR MOTOR OPERATOR’S MANUAL

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 495-0276

FAX

(800) 892-6276

© 2010

www.ingersollrandproducts.com

CCN 99712036