Ingersoll Rand 612058E - Manual
Ingersoll Rand 612058E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – AIR AND LUBE REQUIREMENTS; WARNING; HAZARDOUS PRESSURE. Do not exceed maxiĆ; INSTALLATION
- Page 3 – FIGURE 2; LOWER PUMP; PARTS LIST; PUMP ASSEMBLY; Assemble with new service parts.
- Page 4 – TROUBLE SHOOTING; pressure in pump. Remove Obstruction in system.
OPERATOR’S MANUAL
612058–E
RELEASED: 8–15–95
IPP/PSE
INCLUDING:ĂSER VICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING
ALSO INCLUDE MANUALS: 6641X-X AIR MOTOR MANUAL, FORM 3637-2GENERAL INĆ
FORMATION SHEET.
PUMP
3” AIR MOTOR
5:1 RATIO
2 1/4” STROKE
612058–E
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
SERVICE KITS
•
Use only genuine ARO
R
replacement parts to assure compatible
pressure rating and longest service life.
•
637066-B for repair of Air Motor section.
GENERAL DESCRIPTION
This model is designed for high volume delivery of low viscosity fluids
such as motor oil, gear oil or transmission fluids. Material dispensing
accessories and supply lines and fittings must be capable of withstandĆ
ing pressures developed by pump.
•
The ARO 5:1 ratio basic pump assembly consists of a 3" air motor
and ball check lower pump end.
•
The ball check design provides for easy priming of the lower foot
valve. Material is delivered to the pump discharge outlet on both
the up and down stroke.
RATIO x REGULATED AIR PRESSURE TO AIR MOTOR = MAXIMUM FLUID
PRESSURE.
•
The 5:1 ratio is an expression of the relationship between the air
motor area and the lower pump end area. When 150 p.s.i. (10 bar)
air pressure is supplied to the air motor, the lower pump end will
develop a maximum of 786 p.s.i. (54 bar) fluid pressure (at no flow)
- as the fluid control is opened, the flow rate will increase as the air
motor cycle rate increases to keep up with the demand.
Air Motor
FIGURE 1
66419
25 5/16
15 11/16”
(643 mm)
(398.4 mm)
1/2 NPT
Mat’l Outlet
1 1/2 NPT
Mat’l Inlet
Lower Pump
Air Inlet
2608
Connector
INCLUDED BUT NOT
SHOWN: 210 COUPLER
F022
OPERATING AND SAFETY PRECAUTIONS
•
HEED ALL WARNINGS.
•
DO NOT EXCEED MAXIMUM WORKING PRESSURE OF 786 PSI (54
BAR) AT 150 PSI (10 BAR) AIR INLET PRESSURE.
WARNING
: HIGH PRESSURE DEVICE. Improper usage of
this equipment could result in serious injury. The possibility
of injection into the flesh is a potential hazard. Never allow any
part of the human body to come in front of or in direct contact
with the material outlet. An injection injury can be serious. If
injection should occur, contact a qualified physician immediĆ
ately for treatment.
•
COMPONENTRUPTURE.
This pump is capable of producing high material
pressure as stated on pump model plate.
•
Be sure material hoses and other components are able to withstand fluid
pressures developed by this pump.
•
Do not operate pump continuously at speeds in excess of 75 cycles per minĆ
ute.
•
Disconnect air line from pump air motor when system sits idle for long periĆ
ods of time.
•
Materials and solvents being pumped by this pump must be compatible with
the parts of this pump that come in contact with the material and solvent.
WARNING
: PREVENT STATIC SPARKING. If static sparking
occurs, fire or explosion could result. Pump, dispensing
valve and containers must be grounded when handling inĆ
flammable fluids such as petroleum products, paints, lacĆ
quers, etc. and wherever discharge of static electricity is a
hazard.
•
Use grounded hoses (static wire) and be sure the object is grounded if it can
produce a static charge.
THE ARO CORPORATION
D
ONE ARO CENTER
D
BRYAN, OHIO 43506–0151
E
1995 THE ARO CORPORATION
D
PRINTED IN U.S.A.
&
(419) 636–4242
D
FAX (419) 636–2115
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
612058-E Page 2of 4 AIR AND LUBE REQUIREMENTS WARNING HAZARDOUS PRESSURE. Do not exceed maxiĆ mum inlet air pressure of 150 psi (10 bar). Operating pump at higher pressure may cause pump damage and/or personal inĆ jury and/or property damage. • Refer to general information sheet for additional safet...
612058-E PAGE 3 of 4 FIGURE 2 66419 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1/2" NPT 1 1/2" NPT Air MotorPiston Rod F023 LOWER PUMP PARTS LIST ITEM Description Qty Part No. 1 Seal 1 93992 2 Washer 1 90123 3 Spring 1 90120 4 Washer 1 90125 - 5 Tube 1 76506 6 Set Screw 1 Y23-191 7 Follower 1 75...
TROUBLE SHOOTING 612058-E Page 4 of 4 No Material. (Stalled Pump.) • Obstructed Material Line. Disconnect air supply. Relieve all fluid pressure in pump. Remove Obstruction in system. No Material (Pump Continually Cycles.) • Empty material supply. Shut down system. Replenish material supply. Materia...