OPERATOR’S MANUAL

23644

Ć400

RELEASED:

1-30-81

REVISED:

6-23-00

(REV. B)

ARO STOP

R

OPERATION, INSTALLATION & MAINTENANCE

23644-400

PUMP SAVER CONTROL VALVE - 1/2” PIPE SIZE

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

GENERAL DESCRIPTION

This device is to terminate operation of a 4" to 7" reciprocating type air

motor in the event of a ruptured outlet hose or the pump runs out of meĆ

dia.

For compressed air use only.

Operating Pressure Range

20 Ć 175 p.s.i. (1.4 Ć 12 bar)

. . .

Temperature Range

0

_

to 180

_

F (Ć18

_

to 82

_

C)

. . . . . . . . .

OPERATION

The AROĆSTOP control valve senses an increased volume of air to the

pump, beyond the preadjusted setting, and shuts off the air supply to

the pump. The runaway" condition may be caused by any of the followĆ

ing: 1.)depleted pumping material, 2.)a ruptured line on the outlet of

the pump, 3.)excessive cavitation in the material supply.

INSTALLATION

The AROĆSTOP valve should be installed in a filtered and regulated air

line as close to the inlet of the pump as possible. Equipment other than

a lubricator should not be installed between the AROĆSTOP valve and

the inlet of the pump. Upstream plumbing from the AROĆSTOP valve

should be 1/2" minimum. A swivel or 1/2" connector & coupler should be

installed before the AROĆSTOP valve to facilitate easy adjustment.

Use one AROĆSTOP valve for each pump. See typical installation phoĆ

to.

B

A

C

ADJUSTMENT

THE AROĆSTOP VALVE MUST BE PROPERLY ADJUSTED AND

TESTED. THE INSTALLATION SHOULD BE TESTED REGULARLY

AND ADJUSTED WHEN A CHANGE IN OPERATING CONDITIONS

OCCURS.

1. Turn A" sleeve clockwise to the maximum inward position. See arĆ

row on sleeve of AROĆSTOP valve.

2. Supply AROĆSTOP valve with desired inlet operating pressure.

3. Depress C" reset button on the AROĆSTOP valve to start the

pump. Open the pump outlet to the desired flow condition.

4. Turn A" sleeve counterclockwise slowly until the pump stops.

5. Turn A" sleeve clockwise one turn and tighten B" locking nut

against body.

6. To restart pump, depress the C" reset button and hold it in for

approx. 3 seconds or until pump primes. If the pump does not reset

and run, repeat step (5). If pump operates, continue on th Test SecĆ

tion.

TEST:

7. To test installation, with the pump operating, remove the pump (or

siphon tube)from the material supply. If the pump shuts off, the unit

is set properly.

8. If the pump continues to turn, resubmerge the pump (or siphon

tube)in the material supply. Loosen the B" locking nut and turn the

A" sleeve counterclockwise approx. one half turn, tighten B" lockĆ

ing nut, and repeat step (7).

RESTART:

9. To restart: Remedy the cause of the shutdown. If the air supply is

shutĆoff, turn the air back on.

10. Depress the C" reset button and hold it in approx. 3 seconds.

E

2000

D

PRINTED IN U.S.A.

&

(419) 636-4242

D

FAX (419) 633-1674

INGERSOLL-RAND COMPANY

P.O. BOX 151

D

ONE ARO CENTER

D

BRYAN, OHIO 43506Ć0151

AROĆSTOP

R

is a registered trademark of The Aro Corporation.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Ingersoll Rand Models