InFocus SP-CWRS232 - Manual

InFocus SP-CWRS232

InFocus SP-CWRS232 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4
Loading the manual

LP225 RS-232 Command Values

Communication Configuration

To control one of the above noted projectors from an RS-232 control system, connect the serial cable or a null modem cable and
the InFocus RS-232 Adapter

(SP-CWRS232)

and set the control system serial port settings to match the following communication

configuration*:

RS-232 Port Settings

Setting

Value

Bits per second

19,200

Data bits

8

Parity

None

Stop bits

1

Flow control

None

Emulation

VT100

RS-232 Connection for LP225

The RS-232/serial connection for these projectors is located on the PC side of the CableWizard II connection hub. Use the serial
cable (IFS part # 210-0107-xx) to connect the CableWizard II to the serial port of the computer source.

Note: CableWizard

3

(p/n SP-CW3) does not support RS-232. You must Use CableWizard II (p/n SP-CW2) and the InFocus

serial cable.

Command Format

All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses. The request can be a read request
(indicated by a "?") or a write request (indicated by 1 to 4 ASCII digits).

A read request example:

(AAA?) where

( starts the command

AAA denotes the command

? denotes the read request

) ends the command

A read command returns the range and the current setting, for example:

Read Command Examples

Function

Command

Response

Brightness

(BRT?)

(0-22, 10)

Volume

(VOL?)

(0-80, 0)

Lamp Hours

(LMP?)

(0-9999, 421)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.