- Page 2 – INSPECT NEW UNIT; WARNING; LOCATION; CAUTION; Failure to follow this caution may result in property damage.; Top surface of platform must be above estimated snow-
- Page 3 – Minimum; Contact local distributor for hurricane hold; Inadequate unit support may cause excessive vibration,; REFRIGERATION SYSTEM
- Page 4 – cooling; PRODUCT OPERATION HAZARD; sale literature for start as-
- Page 7 – ELECTRICAL WIRING
- Page 8 – LEGEND
- Page 9 – DEFROST SYSTEM
- Page 10 – Defrost Control Board; T1 C C O
- Page 11 – START; A. UNITS WITH COOLING MODE TXV
- Page 12 – SEQUENCE OF OPERATION
- Page 14 – Rating Plate (required) Subcooling Temperature; Measured Liquid
- Page 16 – TROUBLESHOOTING
- Page 18 – 10A QUICK REFERENCE GUIDE; WARNINGS
428 01 5106 02
5/14/14
Specifications subject to change without notice.
INSTALLATION INSTRUCTIONS
R
−
410A Split System Heat Pump
N4H3, C4H3, H4H3, T4H3,
N4H4, NXH5, CXH5, HXH5, TXH5
These instructions must be read and understood completely before attempting installation.
DANGER, WARNING, CAUTION, and
NOTE
The signal words
DANGER, WARNING,
CAUTION,
and
NOTE
are used to identify levels of
hazard seriousness. The signal word
DANGER
is
only used on product labels to signify an immediate
hazard. The signal words
WARNING,
CAUTION,
and
NOTE
will be used on product labels and
throughout this manual and other manuals that may
apply to the product.
DANGER
−
Immediate hazards which
will
result in
severe personal injury or death.
WARNING
−
Hazards or unsafe practices which
could
result in severe personal injury or death.
CAUTION
−
Hazards or unsafe practices which
may
result in minor personal injury or product or
property damage.
NOTE
−
Used to highlight suggestions which
will
result in enhanced installation, reliability, or
operation.
Signal Words in Manuals
The signal word
WARNING
is used throughout this
manual in the following manner:
The signal word
CAUTION
is used throughout this
manual in the following manner:
Signal Words on Product Labeling
Signal words are used in combination with colors
and/or pictures on product labels.
WARNING
Safety Labeling and Signal Words
!
CAUTION
WARNING
!
TABLE OF CONTENTS
Inspect New Unit
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Considerations
2
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Location
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clearances
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Support
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigeration System
3
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Wiring
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Defrost System
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Start
−
up Procedure
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant Charge
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sequence of Operation
12
. . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Comfort Alert
t
Diagnostics Codes
17
. . . . . . . . . . . . . .
R
−
410A Quick Reference Guide
18
. . . . . . . . . . . . . . . . .
!
WARNING
DEATH, PERSONAL INJURY, AND/OR PROPERTY
DAMAGE HAZARD
Failure to carefully read and follow this warning
could result in equipment malfunction, property
damage, personal injury and/or death.
Installation or repairs made by unqualified per-
sons could result in equipment malfunction, prop-
erty damage, personal injury and/or death.
The information contained in this manual is in-
tended for use by a qualified service technician fa-
miliar with safety procedures and equipped with
the proper tools and test instruments.
Installation must conform with local building
codes and with the National Electrical Code
NFPA70 current edition or Canadian Electrical
Code Part 1 CSA C.22.1.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for ICP C4H448GKD100
Summary
INSTALLATION INSTRUCTIONS R − 410A Split System Heat Pump 2 428 01 5106 02 Specifications subject to change without notice. INSPECT NEW UNIT After uncrating unit, inspect thoroughly for hidden damage. If damage is found, notify the transportation company immediately and file a concealed damage claim...
INSTALLATION INSTRUCTIONS R − 410A Split System Heat Pump 428 01 5106 02 3 Specifications subject to change without notice. Figure 1 Tie Down Knockouts Base Pan Depth C B A Base Pan Width a” (10mm) dia. Tie Down Knockouts In Base Pan (2 places) View From Top Inches (mm) Base Pan Width x Depth Tie Do...
INSTALLATION INSTRUCTIONS R − 410A Split System Heat Pump 4 428 01 5106 02 Specifications subject to change without notice. Installing with Indoor Piston − cooling operation. (Heat pumps also use an outdoor piston for heating operation, refer to section F.) Check piston size shipped with indoor unit...