  • Page 2 – INSPECT NEW UNIT; WARNING; LOCATION; CAUTION; Failure to follow this caution may result in property damage.; Top surface of platform must be above estimated snow-
  • Page 3 – Minimum; Contact local distributor for hurricane hold; Inadequate unit support may cause excessive vibration,; REFRIGERATION SYSTEM
  • Page 4 – cooling; PRODUCT OPERATION HAZARD; sale literature for start as-
  • Page 7 – ELECTRICAL WIRING
  • Page 8 – LEGEND
  • Page 9 – DEFROST SYSTEM
  • Page 10 – Defrost Control Board; T1 C C O
  • Page 11 – START; A. UNITS WITH COOLING MODE TXV
  • Page 12 – SEQUENCE OF OPERATION
  • Page 14 – Rating Plate (required) Subcooling Temperature; Measured Liquid
  • Page 16 – TROUBLESHOOTING
  • Page 18 – 10A QUICK REFERENCE GUIDE; WARNINGS
Loading the manual

428 01 5106 02

5/14/14

Specifications subject to change without notice.

INSTALLATION INSTRUCTIONS

R

410A Split System Heat Pump

N4H3, C4H3, H4H3, T4H3,

N4H4, NXH5, CXH5, HXH5, TXH5

These instructions must be read and understood completely before attempting installation.

DANGER, WARNING, CAUTION, and

NOTE

The signal words

DANGER, WARNING,

CAUTION,

and

NOTE

are used to identify levels of

hazard seriousness. The signal word

DANGER

is

only used on product labels to signify an immediate

hazard. The signal words

WARNING,

CAUTION,

and

NOTE

will be used on product labels and

throughout this manual and other manuals that may

apply to the product.

DANGER

Immediate hazards which

will

result in

severe personal injury or death.

WARNING

Hazards or unsafe practices which

could

result in severe personal injury or death.

CAUTION

Hazards or unsafe practices which

may

result in minor personal injury or product or

property damage.

NOTE

Used to highlight suggestions which

will

result in enhanced installation, reliability, or

operation.

Signal Words in Manuals

The signal word

WARNING

is used throughout this

manual in the following manner:

The signal word

CAUTION

is used throughout this

manual in the following manner:

Signal Words on Product Labeling

Signal words are used in combination with colors

and/or pictures on product labels.

WARNING

Safety Labeling and Signal Words

!

CAUTION

WARNING

!

TABLE OF CONTENTS

Inspect New Unit

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Considerations

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Location

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Clearances

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit Support

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Refrigeration System

3

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Wiring

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Defrost System

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Start

up Procedure

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Refrigerant Charge

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sequence of Operation

12

. . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Comfort Alert

t

Diagnostics Codes

17

. . . . . . . . . . . . . .

R

410A Quick Reference Guide

18

. . . . . . . . . . . . . . . . .

!

WARNING

DEATH, PERSONAL INJURY, AND/OR PROPERTY

DAMAGE HAZARD
Failure to carefully read and follow this warning

could result in equipment malfunction, property

damage, personal injury and/or death.
Installation or repairs made by unqualified per-

sons could result in equipment malfunction, prop-

erty damage, personal injury and/or death.
The information contained in this manual is in-

tended for use by a qualified service technician fa-

miliar with safety procedures and equipped with

the proper tools and test instruments.
Installation must conform with local building

codes and with the National Electrical Code

NFPA70 current edition or Canadian Electrical

Code Part 1 CSA C.22.1.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for ICP C4H424GKD100

Summary

Page 2 - INSPECT NEW UNIT; WARNING; LOCATION; CAUTION; Failure to follow this caution may result in property damage.; Top surface of platform must be above estimated snow-

INSTALLATION INSTRUCTIONS R − 410A Split System Heat Pump 2 428 01 5106 02 Specifications subject to change without notice. INSPECT NEW UNIT After uncrating unit, inspect thoroughly for hidden damage. If damage is found, notify the transportation company immediately and file a concealed damage claim...

Page 3 - Minimum; Contact local distributor for hurricane hold; Inadequate unit support may cause excessive vibration,; REFRIGERATION SYSTEM

INSTALLATION INSTRUCTIONS R − 410A Split System Heat Pump 428 01 5106 02 3 Specifications subject to change without notice. Figure 1 Tie Down Knockouts Base Pan Depth C B A Base Pan Width a” (10mm) dia. Tie Down Knockouts In Base Pan (2 places) View From Top Inches (mm) Base Pan Width x Depth Tie Do...

Page 4 - cooling; PRODUCT OPERATION HAZARD; sale literature for start as-

INSTALLATION INSTRUCTIONS R − 410A Split System Heat Pump 4 428 01 5106 02 Specifications subject to change without notice. Installing with Indoor Piston − cooling operation. (Heat pumps also use an outdoor piston for heating operation, refer to section F.) Check piston size shipped with indoor unit...

Other ICP Models