Hubbell Industrial Controls, Inc
Lifting Magnet Power Supplies
Specifications 4320 * January 2000
Replaces February 1994
4320
General
Hubbell offers the Type 4320 diode rectifier,
specifically designed and rated for the demand-
ing requirements where short circuits on the DC
output bus are common or probably. The unit is
ideally suited for applications such as scrap lift-
ing magnets or cranes.
Addressing the common problem of blown semi-
conductor fuses resulting from cut magnet ca-
bles, shorted magnets, or crane rail faults. The
4320 offers a rectifier system that eliminates all
fusing in the rectifier. Traditional rectifier design
incorporates the use of silver and, fast acting,
current limiting, semi-conductor fuses to protect
rectifier diodes in the event of a DC fault. The
4320 rectifier design eliminates the need for
these fuses.
The 4320 rectifier design will trip the unit’s AC
input breaker in the event of a DC output bus
fault. After the fault is cleared, the user simply
resets the unit’s AC breaker and the unit is op-
erational.
Cost Savings:
♦
No blown fuses to replace
♦
No spare fuses to inventory
♦
Downtime associated with changing power
semi-conductor fuses is eliminated
Standard Features of the Type
4320 Rectifier:
♦
AC input voltage: 460V, 3Ph, 60Hz.
♦
Nominal DC output: 240VDC
♦
AC molded case circuit breaker
♦
Dry Type isolation transformer: Transformer
has one 5% tap above and below nominal
input voltage
♦
DC bleed resistor
♦
Full wave, six pulse, diode rectifier assem-
bly; mounted on oversize extruded alumi-
num head sinks
♦
Diode peak inverse voltage to be six times
the bridge AC RMS voltage
♦
Heavy Duty surge suppression specifically
rated for highly inductive load kick applica-
tion. i.e. Magnets
♦
Power on indication light
♦
Industrial duty floor mounted NEMA 2 in-
door, or NEMA 3R outdoor, convection
cooled, vented enclosure with hinged door
access
♦
Single side access to all components
♦
Enclosure grounding lug
Options:
♦
DC ammeter and/or voltmeter
♦
Remote on/off pushbutton
♦
Flange mounted on/off pushbutton