Hubbell Industrial Controls, Inc

Lifting Magnet Power Supplies

Specifications 4320 * January 2000
Replaces February 1994

4320

General

Hubbell offers the Type 4320 diode rectifier,
specifically designed and rated for the demand-
ing requirements where short circuits on the DC
output bus are common or probably. The unit is
ideally suited for applications such as scrap lift-
ing magnets or cranes.

Addressing the common problem of blown semi-
conductor fuses resulting from cut magnet ca-
bles, shorted magnets, or crane rail faults. The
4320 offers a rectifier system that eliminates all
fusing in the rectifier. Traditional rectifier design
incorporates the use of silver and, fast acting,
current limiting, semi-conductor fuses to protect
rectifier diodes in the event of a DC fault. The
4320 rectifier design eliminates the need for
these fuses.

The 4320 rectifier design will trip the unit’s AC
input breaker in the event of a DC output bus
fault. After the fault is cleared, the user simply
resets the unit’s AC breaker and the unit is op-
erational.

Cost Savings:

No blown fuses to replace

No spare fuses to inventory

Downtime associated with changing power

semi-conductor fuses is eliminated

Standard Features of the Type
4320 Rectifier:

AC input voltage: 460V, 3Ph, 60Hz.

Nominal DC output: 240VDC

AC molded case circuit breaker

Dry Type isolation transformer: Transformer

has one 5% tap above and below nominal
input voltage

DC bleed resistor

Full wave, six pulse, diode rectifier assem-

bly; mounted on oversize extruded alumi-
num head sinks

Diode peak inverse voltage to be six times

the bridge AC RMS voltage

Heavy Duty surge suppression specifically

rated for highly inductive load kick applica-
tion. i.e. Magnets

Power on indication light

Industrial duty floor mounted NEMA 2 in-

door, or NEMA 3R outdoor, convection
cooled, vented enclosure with hinged door
access

Single side access to all components

Enclosure grounding lug

Options:

DC ammeter and/or voltmeter

Remote on/off pushbutton

Flange mounted on/off pushbutton

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Hubbell Models

All Hubbell Other