Hotpoint CTF~GC - Manual
Hotpoint CTF~GC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
MODEL
CTF~GC
1. Fruit and vegetable crispers
2. Three adjustable cantilever shelves
3. Butter storage compartment
4. Portable egg tray
5. Freezer door juice-can shelf
6. Easy-Releasem ice trays
7. Temperature controls (both fresh
food and freezer)
8.
Power saver switch
9. Model and serial number
10. Defrost water pan (behind grille)
LATKNN
nch clearance at both sides and a{
e of installation. When building a
consider providing water supply to
refrigerator location. It will simplify connec
tion of optional automatic
icemaker shoulc
you wish to install one at a later date.
Your refrigerator should not be installed where
the temperature will go below 60°F. because
the refrigerator will not run frequently enough
to maintain proper temperatures.
Be sure to install on a floor strong enough to
support a fully loaded refrigerator.
Adjustable legs at the front corners of the re-
frigerator should be set so the refrigerator is
firmly positioned cm the floor, and the fron/ is
raised just enough that the doors close easily
when opened about half-way.Remove the grille
by grasping at [he bottom and pulling up and
out. (See Fig. 1).
.=Q]rn adjustable legs left to raise the refrigera-
‘-“~.right to lower. (See Fig. 2).
—.L
“..”
~
To replace grille, set tabs on hooks at both ends
and push top toward refrigerator
until grille
snaps into place. (See Fig. 3).
ELECTRICAL
CONNECTION
IMPORTANT
(PLEASE READ CAREFULLY)
FORPERSONAL
SAFETY,
THISAPPLIANCE
MUSTBEPROPERLYGROUNDED.
The power cord of this appliance is equipped
with a three-prong
(grounding) plug which
mates with a standard three-prong (grounding)
wall receptacle (Fig. 4) to minimize the possi-
bility of electric shock hazard from this appli-
~nce. The customer should have the wall
‘eceptacle and circuit checked by a qualified
;Iectrician
to make sure the receptacle
is
xoperly grounded,
PREFERRED
Mmm)
V.
(
n
Q
@
,,
%
y,:
‘ ’8’
0
:..
.1.
,4
~@\\
.:
,-
INSURE PROPERGROUND
Fig. 4
EXISTSBEFOREUSE
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility
and obligation of the customer to have it re-
placed with a properly grounded three-prong
wall receptacle.
Do NY-I’,UNDER ANY
‘cnla.mmTAJwEs,
XJll”ORRIm4iovilz
THE THIRD (GROLJND)
1~~~~~~~~~~~~ p~~~~ ~-J~~e
USAGE SITUATKMJS WHERE APPLIANCE’S
POWER CORD WILL BE DISCQNNECTH3
1NFREQUENTL%
TEMPORARYMETHOD
(
gil
ADAPTER PLUGSNOT
)
/
PERMITTEDIN CANADA
t f
ALIGNLARGE
:
PRONGS/SLOTS
>
<-.
e
! ~’
.;’
Q
\
~:’:J;:R.R;;:W_:t
f;;D
Fig. 5
BEFOREUSE
Because of potential safety hazards under cer-
tain conditions,
we strongly recommend
against the use of an adapter plug, However, if
you still elect to use an adapter, where local
codes permit, a TEMPORARY CONNEC-
TION may be made to a properly grounded
two-prong wall receptacle by the use of a UL
listed adapter which is available at most local
hardware stores (Fig. 5). The larger slot in the
adapter must be aligned with the larger slot in
the wall receptacle to provide proper polarity
in the connection of the power cord,
CAUTION: Attaching the adapter ground ter-
minal to the wall receptacle cover screw does
not ground the appliance unless the cover
screw is metal, and not insulated, and the wall
receptacle
is grounded through the house
wiring. The customer should have the circuit
checked bya qualified electrician
to make
sure the receptacle is properly grounded.
When disconnecting the power cord from the
adapter, always hold the adapter with one
hand. If this is not done, the adapter ground
terminal is very likely to break with repeated
use, Should this happen. DO NOT USE the
appliance until a proper ground has again
been established,
USAGE SITUATIONS WHERE APPLIANCE’S
POWER CORD WILL BE DISCONNECTED
FREQUENTLY
—
Do not use an adapter plug in these situations
because frequent disconnecting of the power
cord places undue strain on the adapter and
leads to eventual failure of the adapter ground
terminal. The customer should have the two-
prong wall receptacle
replaced with a three-
pmng (grounding)
receptacle by a qualified
electrician before using the appliance.
The refrigerator should alwaysbe plugged into
its own individual electrical
outiet (115volt,
60 hertz, single phase AC.)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Hotpoint
- Model
- CTF~GC
- Document type
- Manual
- Language(s)
- English
- Pages
- 6
- File size
- 1.4 MB
- Format