Hitachi KP-FD30 - Manual
Hitachi KP-FD30 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ) Session starts when ENQ is sent from master to slave.
- Page 4 – ) Since ACK code cannot be sent, slave sent NAK code to master.; successive NAK code, comms control is aborted.
- Page 6 – seconds elapse
- Page 8 – STX; Text data; ETX; Data
- Page 9 – Comms data description; bytes; Text data details (transmission sequence)
- Page 18 – memorizing a setting value, when changing this item.
15-July-2004
1
KP-FD30 remote control protocol (Rev.1)
1) Comms* specifications
Sync system
Start-stop sync
Bit rate
9600 bps
Data length
8 bits
Start bit
1
Stop bits
1
Parity None
Bit transfer
LSB first
*Comms : Communications
2) Comms control
The remote control software controls all communications. Data send/receive (BSC
handshake) is by transferring TEXT data to the camera controller chip.
3) Comms procedure
The following pages indicate the camera controller chip and remote control software
data protocol. In the description, the camera is designated as slave and the software
as master.
Receive protect timer (time out error)
The receive protect timer for master and slave processes is 1 second. For example,
if 1 block of TEXT data is being received, if the data interval exceeds 1 second, error
is produced and the data are lost. An acknowledgment of data receipt is not
produced.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
15-July-2004 2 a) Transmission from master (normal process) Master Slave ENQ code (05H) 1) ACK code (06H) Transmit code (ASCII code) 2) 3) 4) ACK code (06H) 1) Session starts when ENQ is sent from master to slave. 2) Slave acknowledges by returning ACK to master. 3) Master sends data to slave. 4) Sl...
15-July-2004 4 c) Data transmitted by master (control abort process) Master Slave ENQ code (05H) 1) NAK code (15H) 2) 3) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) 1) Master sends ENQ code to slave. 2) Since ACK code cannot be sent, slave sent NAK code ...
15-July-2004 6 e) Data frame error (Master transmission) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Send data (ASCII code) 4) 3 seconds elapse 3 seconds elapse 5) 6) Send data (ASCII code) Send data (ASCII code) Send data (ASCII code) 3 seconds elapse 1) Session starts when ENQ is sent from...