Hitachi KP-FD30 - Manual

Hitachi KP-FD30

Hitachi KP-FD30 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – ) Session starts when ENQ is sent from master to slave.
  • Page 4 – ) Since ACK code cannot be sent, slave sent NAK code to master.; successive NAK code, comms control is aborted.
  • Page 6 – seconds elapse
  • Page 8 – STX; Text data; ETX; Data
  • Page 9 – Comms data description; bytes; Text data details (transmission sequence)
  • Page 18 – memorizing a setting value, when changing this item.
Loading the manual

15-July-2004

1

KP-FD30 remote control protocol (Rev.1)

1) Comms* specifications

Sync system

Start-stop sync

Bit rate

9600 bps

Data length

8 bits

Start bit

1

Stop bits

1

Parity None
Bit transfer

LSB first

*Comms : Communications

2) Comms control

The remote control software controls all communications. Data send/receive (BSC
handshake) is by transferring TEXT data to the camera controller chip.

3) Comms procedure

The following pages indicate the camera controller chip and remote control software

data protocol. In the description, the camera is designated as slave and the software

as master.

Receive protect timer (time out error)
The receive protect timer for master and slave processes is 1 second. For example,
if 1 block of TEXT data is being received, if the data interval exceeds 1 second, error
is produced and the data are lost. An acknowledgment of data receipt is not
produced.


"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ) Session starts when ENQ is sent from master to slave.

15-July-2004 2 a) Transmission from master (normal process) Master Slave ENQ code (05H) 1) ACK code (06H) Transmit code (ASCII code) 2) 3) 4) ACK code (06H) 1) Session starts when ENQ is sent from master to slave. 2) Slave acknowledges by returning ACK to master. 3) Master sends data to slave. 4) Sl...

Page 4 - ) Since ACK code cannot be sent, slave sent NAK code to master.; successive NAK code, comms control is aborted.

15-July-2004 4 c) Data transmitted by master (control abort process) Master Slave ENQ code (05H) 1) NAK code (15H) 2) 3) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) 1) Master sends ENQ code to slave. 2) Since ACK code cannot be sent, slave sent NAK code ...

Page 6 - seconds elapse

15-July-2004 6 e) Data frame error (Master transmission) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Send data (ASCII code) 4) 3 seconds elapse 3 seconds elapse 5) 6) Send data (ASCII code) Send data (ASCII code) Send data (ASCII code) 3 seconds elapse 1) Session starts when ENQ is sent from...

Other Hitachi Models