Page 3 - Influence for environment; products or equipment.; General cautions for safety; manual and the packing specification manual.; Headline of safety caution; To use this product safely; Caution
Drawing No. Sheet No. Revision 6 K6610091 3/43 2005/2/23 Read and follow all instructions and cautions described in this chapter before using the drive. It is recommended that this manual is kept at a proper location for quick reference. The description related to safety in this chapter may be chang...
Page 5 - turn the power off, and see your sales contact.; Warranty and Limited Liability
Drawing No. Sheet No. Revision 6 K6610091 5/43 2005/2/23 0.2.11 Protect the drive against shocks with the corrugated board and cushioning material provided by the manufacturer, or with Hitachi Approved containers. 0.2.12 When mounting the drive, use the size of screws and the torque recommended in t...
Page 7 - socket
Drawing No. Sheet No. Revision 6 K6610091 7/43 2005/2/23 11 Pin assignment ........................................................................................ 33 11.1 SCSI Bus Connector C1 ............................................................. 33 11.2 Other connectors ......................
Page 8 - Features
Drawing No. Sheet No. Revision 6 K6610091 8/43 2005/2/23 1 Features The Ultrastar 10K300 series uses high performance sputtered disks, GMR heads, and a rotary type voice coil motor to drive the heads. These features provide high capacity, high speed positioning and high reliability. The Ultrastar 10...
Page 9 - Standards and Related Documents
Drawing No. Sheet No. Revision 6 K6610091 9/43 2005/2/23 2 Standards and Related Documents (a) Safety standards It is the user’s responsibility to assure the actual system in which the drive is installed meets the appropriate safety requirements. However, the drive was tested to be in compliance wit...
Page 11 - Table 3.2 Environmental conditions and reliability
Drawing No. Sheet No. Revision 6 K6610091 11/43 2005/2/23 3.2 Environmental conditions and reliability Table 3.2 Environmental conditions and reliability Item Ultrastar 10K300-300 Ultrastar 10K300-147 Ultrastar 10K300-73 Ultrastar 10K300-36 Environmental operating 5 to 55°C conditions Temperature no...
Page 12 - Figure 3.1 Vibration test direction; Test conditions on vibration test are as follows.
Drawing No. Sheet No. Revision 6 K6610091 12/43 2005/2/23 Note 1. Storage capacity does not include spare sector and spare cylinder. Note 2. This is the value in the case that the drive is formatted to 512 Bytes/sector. (1 gigabyte shows 1x10 9 bytes on this document.) Note 3. Ultrastar 10K300 is fo...
Page 14 - 0 IOs per second
Drawing No. Sheet No. Revision 6 K6610091 14/43 2005/2/23 Note 13. When the Ultrastar 10K300-300 is formatted to 512 Bytes/sector, the maximum Logical Block Address is (22ECB25B)h. When the Ultrastar 10K300-147 is formatted to 512 Bytes/sector, the maximum Logical Block Address is (111D69B4)h. When ...
Page 15 - DC Power Requirement; Table 4.1 DC Power Requirement; Power supply Voltage tolerance
Drawing No. Sheet No. Revision 6 K6610091 15/43 2005/2/23 4 DC power Interface 4.1 DC Power Requirement The drives are operated on DC power (+5V, +12V) only. No power sequencing is required. The +5 and +12 Volts can be applied in any order. Table 4.1 DC Power Requirement Power supply Voltage toleran...
Page 18 - so an external terminator is required.
Drawing No. Sheet No. Revision 6 K6610091 18/43 2005/2/23 5 Connecting Methods 5.1 Interface Cable (Daisy Chain) Figure 5.1 Cabling layout (WIDE LVD drive) Note 1. The SCSI bus can accommodate a maximum of 16 units on a WIDE (16-bit) bus, including the host processor, Ultrastar 10K300 units, and oth...
Page 20 - Summary of SCSI Controller
Drawing No. Sheet No. Revision 6 K6610091 20/43 2005/2/23 6 SCSI Interface 6.1 Summary of SCSI Controller The Ultrastar 10K300 SCSI controller interfaces between the drive and the host computer with the Small Computer System Interface (SCSI). (1) ANSI standard The controller supports the SCSI interf...
Page 22 - Table 6.1 SCSI Commands Supported; Operation Code
Drawing No. Sheet No. Revision 6 K6610091 22/43 2005/2/23 6.2 Summary of SCSI Commands The SCSI controller supports the group 0,1, and 2 commands listed in Table 6.1 Table 6.1 SCSI Commands Supported Operation Code Group 0 Command Name 00h 01h 03h 04h 07h 08h 0Ah 0Bh 12h 15h 16h 17h 1Ah 1Bh 1Ch 1Dh ...
Page 23 - Mounting; The following orientations are acceptable.
Drawing No. Sheet No. Revision 6 K6610091 23/43 2005/2/23 Table 6.1 SCSI Commands Supported (Continued) Operation Code Group 2 Command Name 41h 4Ch 4Dh 55h 56h 57h 5Ah 5Eh 5Fh WRITE SAME LOG SELECT LOG SENSE MODE SELECT (10) RESERVE (10) RELEASE (10) MODE SENSE (10) PERSISTENT RESERVE IN PERSISTENT ...
Page 24 - to; Good; HDA upper surface; Figure 7.2 Example for mounting
Drawing No. Sheet No. Revision 6 K6610091 24/43 2005/2/23 7.2 Mounting of the drive 1. Mount the drive with four 6-32 UNC screws. (Screw's torque : 0.588 to 0.784 N·m) 2. Mounting holes (A1,A2,B1,B2,B3) are available for mounting.(See figure 8.3) It is recommended that the 4 holes, (A1,A2 or B1,B3 o...
Page 25 - Figure 7.3 Layout of Mounting holes
Drawing No. Sheet No. Revision 6 K6610091 25/43 2005/2/23 7.3 Mounting dimensions F G H J K L B A C D E Dimension mm A 101.6±0.25 B 95.25±0.25 C 3.18±0.25 D 41.28±0.5 E 44.45±0.25 F 147 max. G 101.6±0.25 H 28.5±0.5 J 41.6±0.25 K 26.1 max. L 6.35±0.25 Figure 7.3 Layout of Mounting holes
Page 26 - Table 7.1 Temperature Limits; Measurement points; Figure 7.4 Temperature Measurement Points
Drawing No. Sheet No. Revision 6 K6610091 26/43 2005/2/23 7.4 Precautions on the off-line test or bench test When the off-line test or bench test is performed the drive should be tightly fixed and cooled. The set-up should be similar to the actual system configuration. 7.5 Cooling of the drive Keep ...
Page 27 - Precautions for handling; thickness of 10mm or more) to prevent from shock and vibration.
Drawing No. Sheet No. Revision 6 K6610091 27/43 2005/2/23 8 Precautions for handling The drive is sensitive to shock, vibration, over voltage, temperature, humidity, corrosive gas, magnetic force and electrostatic discharge. If these forces contact the electrical or mechanical components (magnetic h...
Page 28 - Maintenance; be executed by the host system.
Drawing No. Sheet No. Revision 6 K6610091 28/43 2005/2/23 8.4 Other Precautions 8.4.1 Do not loosen the screws or disassemble the drive. 8.4.2 Do not remove the PCB from the drive or swap the PCB with other drives. 8.4.3 Do not solder the wire or other parts on the PCB, or reconstruct the PCB. 8.4.4...
Page 29 - 0 Physical interface; Table 10.1 Interface connectors; Specifications
Drawing No. Sheet No. Revision 6 K6610091 29/43 2005/2/23 10 Physical interface 10.1 Connector Specifications Use the mating connectors which are electrically and mechanically compatible. The following part numbers indicate the mating connectors. Table 10.1 Interface connectors Interface Name Part n...
Page 31 - Figure 10.2 Connector view
Drawing No. Sheet No. Revision 6 K6610091 31/43 2005/2/23 10.3 Connector Layout WIDE LVD drive C1 SCSI Bus Connector C4 Auxiliary Connector C2 Power Connector Figure 10.1 Connector Layout (WIDE LVD drive) C1 4 3 2 1 68 1 34 2 12 1 11 C2-1 : 12V C2-2 : GND (12V Return) C2-3 : GND (5V Return) C2-4 : 5...
Page 32 - Dimension mm Dimension; Figure 10.4 Connector view
Drawing No. Sheet No. Revision 6 K6610091 32/43 2005/2/23 SCA-2 LVD drive N P D H M W L Dimension mm Dimension mm H 26.1 max. W 101.6±0.25 D 6.35±0.25 L (58) N (7) M 50.8±0.5 P 4.6±0.5 Figure 10.3 Connector Layout (SCA-2 LVD drive) 1 40 41 80 C1 PCB parts side Figure 10.4 Connector view
Page 35 - Table 11.3 Pin assignment of SCSI Bus Connector C1; Do not pull up this signal.
Drawing No. Sheet No. Revision 6 K6610091 35/43 2005/2/23 Table 11.3 Pin assignment of SCSI Bus Connector C1 (SCA-2, Single-ended mode) Signal Name Connector contact No. Signal Name 12V 1 41 GND(12V Return) 12V 2 42 GND(12V Return) 12V 3 43 GND(12V Return) 12V 4 44 MATED1 (Note 2) Open 5 45 Open Ope...
Page 37 - Figure 11.1 LED Driver
Drawing No. Sheet No. Revision 6 K6610091 37/43 2005/2/23 11.2 Other connectors Table 11.5 Pin assignment of Auxiliary Connector C4 (WIDE LVD drive) Pin No. Signal Name Pin No. Signal Name Note 1 -ID0 2 Reserved 3 -ID1 4 Reserved 5 -ID2 6 Reserved 7 -ID3 8 LED(with 150 ohm) See Figure 12.1 9 N.C. 10...
Page 38 - 2 Jumper Socket setting; Jumper connector layout
Drawing No. Sheet No. Revision 6 K6610091 38/43 2005/2/23 12 Jumper Socket setting 12.1 Jumper connector layout WIDE LVD drive Reserved (4)Reserved (6) Auxiliary Connector (C4) 21 ID0 (1)ID1 (3)ID2 (5) ID3 (7) GND (10) N.C. (9) 5V (11) Write Protect (12) LED (8) Reserved (2) 1211 Option Jumper Conne...
Page 40 - Meaning; Meaning
Drawing No. Sheet No. Revision 6 K6610091 40/43 2005/2/23 12.2.2 Disable Auto Start WIDE LVD No. Option Jumper Connector (C3) Meaning Remove the Jumper Socketfor C3-9,10 (Default) 1 Install the Jumper Socketfor C3-9,10 2 Spindle motor starts onlyby SCSI command Spindle motor automatically starts whe...
Page 41 - ID number 0; : ID number x 10sec
Drawing No. Sheet No. Revision 6 K6610091 41/43 2005/2/23 12.2.4 Enable Delayed Start WIDE LVD No. Option Jumper Connector (C3) Meaning Remove the Jumper Socketfor C3-13,14 (Default) 1 Install the Jumper Socketfor C3-13,14 2 Spindle motor automatically starts when the power is on. Spindle motor star...
Page 43 - Table 12.1 Jumper socket; Part number; connector; Table 12.2 Extension connector
Drawing No. Sheet No. Revision 6 K6610091 43/43 2005/2/23 12.3 Jumper socket part number Part numbers of jumper sockets are as follows: Table 12.1 Jumper socket Part number Manufacturer Name MINITEKJUMPER FCI Japan K.K. 86730-001 Connector Option Jumper Connector (C3) 12.4 Extension connector Part n...