Page 2 - English
© 2004 Hasselblad A/S. All rights reserved. Flextight 646 User's Guide, Part No 70030050, revision A. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Hasselblad A/S. Hasselblad A/S assumes no ...
Page 3 - Table of Contents; Hardware Reference - Flextight 646
Table of Contents User's Guide - Flextight 646 Table of Contents 3 English Hardware Reference - Flextight 646 5 Warnings and Restrictions 6 System Requirements 7 Front Panel 9 Back Panel & Connectors 10 Cut-Away View 11 Setting up the Scanner 12 Environmental Requirements 12 Electrical Requireme...
Page 5 - Hardware Reference - Flextight
Hardware Reference - Flextight 646 This manual provides important information about using your Flextight 646 scanner. Topics include: • Important warnings and restrictions • System requirements • Diagrams of the front panel, rear panel, and internal structure of the Flextight 646 scanner • Installat...
Page 6 - Warnings and Restrictions
Warnings and Restrictions • Read all of the included documentation before attempting to install and use the scanner. • Do not touch the originals and/or the original holder while scanning. • Do not start scanning or previewing until an original holder with an original has been mounted. • The origina...
Page 7 - System Requirements
System Requirements Below are the basic hardware requirements for the PC or Macintosh system to which the scanner is to be connected. For information about the processor, operating system, RAM and harddisk requirements please refer to the “Software Reference” manual, that comes with the FlexColor so...
Page 9 - Transparency Holder Guide; Front Panel; Figure 1: Front panel features of Flextight 646
Front Panel A Feed Table: place original holders here for scanning. B Light Area: for viewing originals. The grid helps you to align your transparent originals. C Transparency Holder Guide : all transparency holders fit between two rails to keep them straight. D Original Holder Clasp: all original h...
Page 10 - plug the power cable into this socket.; FireWire Interface Sockets:; and connect it to your computer. You can use the second plug to; Back Panel & Connectors; Figure 2: Back panel features of Flextight 646
Back Panel & Connectors A Power Cable Socket: plug the power cable into this socket. B FireWire Interface Sockets: plug a FireWire cable (max. 6 m) here and connect it to your computer. You can use the second plug to connect another device (hard disk, printer etc.) to the FireWire chain. User's ...
Page 11 - Positioning Lead Screws:
Cut-Away View A CCD Housing: this movable platform contains the light sensor and holds the optics. B Positioning Lead Screws: for positioning of the CCD housing and optics housing for the appropriate resolution and original size. C Optics Housing: focuses the image of the original on the CCD. D Uppe...
Page 12 - Environmental Requirements; Setting up the Scanner
Setting up the Scanner Environmental Requirements Set up the scanner in a location that fulfils the following requirements: • Keep the scanner away from sources of heat, such as direct sunlight or a radiator. Warm temperatures will degrade the quality of your scans - for best results, work in a cool...
Page 13 - Installation Procedure, FireWire Interface; FlexColor
Installation Procedure, FireWire Interface 1. Place the scanner on a table near your computer with the front facing away from you. Make sure that the location you choose meets all environmental - and electrical requirements as described on page 11. 2. When using a FireWire interface connection, it i...
Page 14 - Attaching/Detaching the Feed Table; Figure 4: Attaching/Detaching the Feed Table
Attaching/Detaching the Feed Table To attach the feed table correctly onto the scanner lead the brackets (B) as far as they go into the slits (C) in the scanner base, then lower the table and pull it slightly backwards to ensure that the notches (D) catch the bottom of the slits. To detach the feed ...
Page 15 - Mounting/Dismounting of the Cabinet; Figure 5: Mounting/Dismounting of the Cabinet
Mounting/Dismounting of the Cabinet To dismount the cabinet (A) remove the two screws (B) at the scanner back using a 2.5 mm allen key, then pull the cabinet upwards. When mounting the cabinet, make sure that it catches the bends (C) in both sides, then lower it slowly while making sure that it goes...
Page 16 - Operating the Scanner; Figure 6: Operating the Flextight 646 scanner
User's Guide - Flextight 646 Hardware Reference - Flextight 646 16 Operating the Scanner English FLEXTIGHT ORIGINAL HOLDER PATENT PENDING à à E à à A D B C à à K L J F H G à M Figure 6: Operating the Flextight 646 scanner
Page 20 - True Resolutions; Calibrating the Scanner; Resolutions; Table 1: True Resolutions
Resolutions True Resolutions The table below shows the max. resolutions (in ppi) available with each of the original holders when scanning in True Resolutions mode. Calibrating the Scanner The scanner requires two types of calibration: • Focus calibration adjusts the positioning of the scanner's opt...
Page 21 - Focus Calibration; Use procedure below to make Focus Calibration:
Focus Calibration The Flextight 646 scanner uses an adjustable zoom and focus mechanism to optimize its scanning resolution for each of the original formats it can handle. If you suspect your scans are not as sharp as they should be, then you may need to calibrate your scanner. Note that you must no...
Page 22 - White Calibration for Reflectives; Use procedure below to make White Calibration:
White Calibration for Reflectives The Flextight scanner uses a white reference to make sure that all elements in the scanner's CCD react consistently to light brightnesses. The scanner has been calibrated from the factory, and the calibration data is stored in the scanner’s flash PROM. As the scanne...
Page 23 - Calibrate; . The scanner will take several scans of the white
5. Click on Calibrate . The scanner will take several scans of the white target. The process will take about eight minutes. User's Guide - Flextight 646 Hardware Reference - Flextight 646 23 Calibrating the Scanner English Figure 8: Positioning the white calibration sheet on the reflective holder Al...
Page 24 - Replacing the Light Tubes; Figure 9: Replacing the Light Tubes
User's Guide - Flextight 646 Hardware Reference - Flextight 646 24 Replacing the Light Tubes English PRESS PULL OUT PULL OUT PRESS à D E C B A Figure 9: Replacing the Light Tubes
Page 25 - General; Follow procedure below to replace a tube:
Replacing the Light Tubes General The Flextight 646 contains two light tubes: one for illuminating reflective originals from above, the other for shining light through transparencies from below. Replacing the Light Tubes If your scans are suddenly coming out black (or all white if you are scanning n...
Page 27 - Cleaning the External Surface of the Scanner
9. Connect the plug (C) . 10. IMPORTANT: The "T" on the lamp board cover (E) indicates the socket for the transparencies tube. 11. Mount the cabinet (B) and the feed table (A) following the reverse of the procedure used when removing them. NOTE! When mounting the cabinet (B) make sure that i...
Page 28 - Max. 60 W during operation; Technical Specifications
Technical Specifications Power Connector: Power Consumption Max. 60 W during operation Power Requirements 100-240V AC, 1.3A, 50-60Hz Interface to Computer FireWire (IEEE 1394) Front Panel One multifunction switch (on/off switch) with integrated status light Drum Force 1kg (2.2lbs) Operating Environm...
Page 29 - a Class A digital device, pursuant to Part 15 of the FCC Rules. These; FCC Notice
FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This e...
Page 30 - CE - Declaration of Conformity; Declaration of conformity
CE - Declaration of Conformity User's Guide - Flextight 646 Hardware Reference - Flextight 646 30 CE - Declaration of Conformity English HASSELBLAD A/S HEJREVEJ 30DK - 2400 COPENHAGEN NVTELEPHONE +45 7026 0800TELEFAX +45 7026 0900REG./VAT NO. 18635445 www.hasselblad.com Declaration of conformity App...