Hanna Instruments HI 9033 - Manual

Hanna Instruments HI 9033

Hanna Instruments HI 9033 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
Page: / 11

Table of Contents:

  • Page 2 – P R E L I M I N A R Y E X A M I N A T I O N
  • Page 4 – O P E R A T I O N A L G U I D E
  • Page 5 – calibration solutions see; C A L I B R A T I O N; TEMPERATURE EFFECT; conductivity probe features a built-in temperature sensor; AFTER MEASUREMENTS
  • Page 9 – W A R R A N T Y; CONDUCTIVITY & TDS CALIBRATION SOLUTIONS; ChecktempC; A C C E S S O R I E S; All Hanna Instruments
  • Page 10 – C E D E C L A R A T I O N O F C O N F O R M I T Y
  • Page 11 – SALES AND TECHNICAL SERVICE CONTACTS
Loading the manual

Instruction Manual

HI

9033 • HI

9034

Waterproof

Multi-Range

EC and TDS Meters

for Field Applications

w w w . h a n n a i n s t . c o m

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - P R E L I M I N A R Y E X A M I N A T I O N

3 2 HI 9033 and HI 9034 multi-range conductivity and TDS meters, have been designed for extended use in wet, humid, dusty and muddy conditions. These meters utilize the latest in four-ring potentiometric technologywhich has been proven to provide higher accuracy than the commonamperometric method. H...

Page 4 - O P E R A T I O N A L G U I D E

7 6 INITIAL PREPARATION Each meter is supplied complete with a 9 V battery. Remove the backcover, unwrap the battery and install it while paying attention to itspolarity its (see "Battery Replacement" section). Connect the probe to the meter securely byaligning the pins with the socket, push...

Page 5 - calibration solutions see; C A L I B R A T I O N; TEMPERATURE EFFECT; conductivity probe features a built-in temperature sensor; AFTER MEASUREMENTS

9 8 For best results, choose a calibration solution with a conductivity orTDS value as close as possible to the sample to be measured.For example, for measurements in the 2 to 20 mS/cm range, use the HI 7030 (12.88 mS/cm) conductivity calibration solution. For accurate calibration, use two beakers f...