Goodman IO-431 - Manual

Goodman IO-431

Goodman IO-431 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Important Safety Instructions; CA RBON MONOXIDE POISONING HAZAR D; for Amana
  • Page 3 – indoor installation; Ductwork
  • Page 4 – ASPF; Table 1; Electric Heat; ONLY; HEAT KIT NOMINAL kW; Table 2; CFM; CFM; Table 4; HKR Installation
  • Page 5 – must; be in agreement with the unit nameplate power require-; Nominal Input; Table 5; Wire Sizing; Table 6; to; Maximum Allowable Length in Feet; Wire Size; Electrical Connections – Supply Voltage; USE COPPER CONDUCTORS ONLY.; Air Handler With Non-Circuit Breaker Heat Kits
  • Page 6 – Refrigerant Lines; Quench all welded joints with water or a wet rag.; CAUTION; slide; Figure 1; AFTER THE TAILPIECE HAS COOLED; Figure 2
  • Page 7 – Downflow Conversion; Table 7; Figures 3 through 5; Figure 3; Figure 5; Horizontal Conversion; Table 8
  • Page 8 – See Figure 6; Figure 6; Condensate Removal; Figure 7
  • Page 9 – Achieve 2% Low Leakage Rate; CFM Delivery; Regular Maintenance; NOT; Table 9
  • Page 10 – ASPF Thermostat Connections; WARNING; COOLING UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW; The following sections will be detailed:
  • Page 11 – COOLING UNIT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE
  • Page 12 – HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE
  • Page 13 – ASPF Wiring Diagram
  • Page 14 – THIS PAGE LEFT INTENTIONALLY BLANK
  • Page 15 – SPLIT SYSTEMS; AIR CONDITIONING AND HEAT PUMP HOMEOWNER’S; Replace or Clean Filter; Never operate unit without a filter in-; Compressor; Check the thermostat to confirm that it is properly set.; EFORE
Loading the manual

© 2007 - 2012 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com - or - www.amana-hac.com

P/N: IO-431

Date: May 2012

ASPF

AIR HANDLERS
INSTALLATION & OPERATING INSTRUCTIONS

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

ATTENTION INSTALLING PERSONNEL

Prior to installation, thoroughly familiarize yourself with this Installation Manual.

Observe all safety warnings. During installation or repair, caution is to be observed.

It is your responsibility to install the product safely and to educate the customer on its safe use.

CONTENTS

Important Safety Instructions ............................................. 2
Shipping Inspection ........................................................... 3
Codes & Regulations ........................................................ 3
Replacement Parts ............................................................ 3
Pre-Installation Instructions ............................................... 3
Location ............................................................................. 3
Ductwork ........................................................................... 3

Return Ductwork .............................................................. 4
Return Air Filters .............................................................. 4

Electric Heat ...................................................................... 4
HKR Installation ................................................................. 4
Electrical Supply Wire and MOP ....................................... 4

Building Electrical Service Inspection .............................. 5
Wire Sizing ...................................................................... 5
Maximum Overcurrent Protection (MOP) ........................ 5
Electrical Connections – Supply Voltage ......................... 5

Air Handler Only (Non-Heat Kit Models) ..................... 5
Air Handler With Non-Circuit Breaker Heat Kits .......... 5
Air Handler With Heat Kits

Containing a Circuit Breaker ................................... 5

Low Voltage Connections ........................................... 6

Refrigerant Lines ............................................................... 6

Tubing Preparation .......................................................... 6
Post Brazing .................................................................... 6
Piping Size ...................................................................... 6
Special Instructions ......................................................... 6

Downflow Conversion ....................................................... 7
Horizontal Conversion ....................................................... 7
Condensate Removal ........................................................ 8
Achieve 2% Low Leakage Rate ........................................ 9
ASPF Motor ....................................................................... 9

CFM Delivery ................................................................... 9

Start-Up Procedure ........................................................... 9
Regular Maintenance ........................................................ 9
ASPF Thermostat Connections ....................................... 10
Cooling Unit w/Optional Heat Kits

of 10kW and Below ................................................... 10

Cooling Unit w/Optional Heat Kits

of 15kW and Above
and Room Thermostat w/Two Stages of Heat ........... 11

Heat Pump Unit/Optional Heat Kits

of 10kW and Below ................................................... 11

Heat Pump Unit w/Optional Heat Kits

of 15kW and Above ................................................... 12

ASPF Wiring Diagram ..................................................... 13

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Important Safety Instructions; CA RBON MONOXIDE POISONING HAZAR D; for Amana

2 Important Safety Instructions The following symbols and labels are used throughout thismanual to indicate immediate or potential safety hazards. Itis the owner’s and installer’s responsibility to read and com-ply with all safety information and instructions accompanyingthese symbols. Failure to he...

Page 3 - indoor installation; Ductwork

3 IMPORTANT: To register your Goodman ® brand unit, go to www.goodmanmfg.com and click on “Warranty Registration”.Complete registration as prompted. To register your Amana ® brand unit, go to www.amana- hac.com and click “Warranty Registraion”. Complete regis-tration as prompted. Product limited war...

Page 4 - ASPF; Table 1; Electric Heat; ONLY; HEAT KIT NOMINAL kW; Table 2; CFM; CFM; Table 4; HKR Installation

4 Return Ductwork DO NOT TERMINATE THE RETURN DUCTWORK IN ANAREA THAT CAN INTRODUCE TOXIC, OR OBJECTION-ABLE FUMES/ODORS INTO THE DUCTWORK. The returnductwork is to be introduced into the air handler bottom (upflowconfiguration). Return Air Filters Each installation must include a return air filter....

Other Goodman Models

All Goodman Other