Goodman IO-367B - Manual

Goodman IO-367B

Goodman IO-367B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – REPLACEMENT PARTS; CONSUMER AFFAIRS; SAFETY INSTRUCTIONS; Keep this literature in a safe place for future reference.; WARNING; Index
  • Page 3 – HIGH; ONLY; GENERAL INFORMATION; This unit is approved for outdoor installation ONLY.; EPA R
  • Page 4 – UNIT LOCATION; Remove wood shipping rails prior to; : Unit should be energized 24 hours prior; Appliance is shipped from factory for vertical duct; ELECTRICAL ENTRANCE LOCATIONS
  • Page 5 – MOVED; Please follow the instructions below to remove brace.; STAND; CAUTION; The struts are located in the
  • Page 6 – CLEARANCES; UNIT CLEARANCES; ROOF CURB POST-INSTALLATION; ROOF TOP DUCT CONNECTIONS
  • Page 7 – RIGGING DETAILS; If using bottom discharge with roof curb, duct-; CG; CORNER & CENTER OF GRAVITY LOCATIONS
  • Page 8 – Unit Shi ppi ng W eight; DATA; These weights are without accessories installed.; ELECTRICAL WIRING; If supply voltage is 208V, all leads on primary of trans-
  • Page 9 – A weather-tight disconnect switch, properly sized for; POWER AND LOW VOLTAGE BLOCK LOCATIONS; Areas Without Convenience Outlet; A 24V thermostat must be installed for unit operation.
  • Page 10 – TERMINAL THE RMO STAT; *Optional field installed heat connections; CIRCULATING AIR AND FILTERS; Drain Connection
  • Page 11 – . Set the thermostat in the conditioned; “OFF”; the machines are
  • Page 12 – Utilization Voltage -; The voltage of the line terminals of the; Percent voltage unbalance MUST NOT exceed 2%; BELT DRIVE; Section on high static tables may require a field motor; DRIVE BELT TENSION ADJUSTMENT; RECOMMENDED POUNDS OF FORCE PER BELT; accordance with rotation arrow shown on
  • Page 13 – AIR FLOW ADJUSTMENTS
  • Page 14 – MOTOR SHEAVE ADJUSTMENTS; FORCE BELTS OVER GROOVES.; MAINTENANCE
  • Page 15 – SERVICE
  • Page 16 – Unit factory shipped with sheave set at 2.5 turns open.; CPC240 ST ANDARD BELT DRIVE
  • Page 17 – CPC240 HIG H STAT IC BELT DRIVE
  • Page 18 – APPENDIX B ELECTRICAL DATA; ATTENTION INSTALLING PERSONNEL; BD STD ST ATI C; ELECTRI CAL DATA; NOTE: See unit nameplate for proper overcurrent protection.; ELECTR ICAL DATA
  • Page 19 – APPENDIX C UNIT DIMENSIONS; Model
Loading the manual

All information contained herein is subject to change without notice.

I

NSTALLATION

I

NSTRUCTIONS

F

OR

L

IGHT

C

OMMERCIAL

S

ELF

-C

ONTAINED

P

ACKAGED

H

EATING

& C

OOLING

U

NIT

15 & 20 T

ON

CPC

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

ATTENTION INSTALLING PERSONNEL

Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings.

During installation or repair, caution is to be observed.

It is your responsibility to install the product safely and to educate the customer on its safe use.

C

US

®

NOTE: Please contact your distributor or

our website for the applicable
Specification Sheet referred to in
this manual.

These installation instructions cover the

outdoor

installation of single package electric heating and
cooling units. See the Specification Sheet applicable
to your model for information regarding accessories.

©

2010 Goodman Manufacturing Company, L.P.

5151 San Felipe, Suite 500

Houston, TX 77056

www.goodmanmfg.com

www.amana-hac.com

IO-367B

7/10

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - REPLACEMENT PARTS; CONSUMER AFFAIRS; SAFETY INSTRUCTIONS; Keep this literature in a safe place for future reference.; WARNING; Index

2 REPLACEMENT PARTS O RDERING P ARTS When reporting shortages or damages, or ordering repairparts, give the complete unit model and serial numbersas stamped on the unit’s nameplate. Replacement parts for this appliance are availablethrough your contractor or local distributor. For thelocation of you...

Page 3 - HIGH; ONLY; GENERAL INFORMATION; This unit is approved for outdoor installation ONLY.; EPA R

3 WARNING T O PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE. HIGH   VOLTAGE! I NSTALLATION   AND   REPAIR   OF   THIS   UNIT   SHOULD   BE   PERFORMED   ONLY   ...

Page 4 - UNIT LOCATION; Remove wood shipping rails prior to; : Unit should be energized 24 hours prior; Appliance is shipped from factory for vertical duct; ELECTRICAL ENTRANCE LOCATIONS

4 UNIT LOCATION T O PREVENT POSSIBLE EQUIPMENT DAMAGE , PROPERTY DAMAGE , PERSONAL INJURY OR DEATH , THE FOLLOWING BULLET POINTS MUST BE OBSERVED WHEN INSTALLING THE UNIT . WARNING IMPORTANT NOTE: Remove wood shipping rails prior to installation of the unit. See important note under Roof Curb Instal...