Goodman GAS-FIRED WARM AIR FURNACE - Manual

Goodman GAS-FIRED WARM AIR FURNACE

Goodman GAS-FIRED WARM AIR FURNACE – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
Page: / 56

Table of Contents:

  • Page 2 – Table of Contents
  • Page 3 – WARNING; DIP
  • Page 4 – CARBON MONOXIDE POISONING HAZARD; NSTALLER; Notify carrier promptly and request an inspection.
  • Page 5 – I . C O M P O N E N T I D E N T I F I C AT I O N; Counterflow/Horizontal; ER
  • Page 7 – ONLY; Section V, Combustion and Ventilation; LECTROSTATIC; III. PRODUCT APPLICATION
  • Page 8 – IV. LOCATION REQUIREMENTS & CONSIDERATIONS; ENERAL
  • Page 9 – Suspended Furnace; The following vent testing procedure is reproduced from the; American; a. Seal any unused openings in the venting system
  • Page 10 – HERMOSTAT; Hot or cold air from registers.; Thermostat Influences
  • Page 11 – Equipment Located in Confined Spaces All Air from Outdoors—; When communicating with the outdoors through vertical ducts,; Equipment Located in Confined Spaces All Air from Outdoors; When communicating with the outdoors through horizontal ducts,; Equipment Located in Confined Spaces All Air from Outdoors.; When ducts are used, they shall be of the same cross-sectional; Equipment Located in Confined Spaces All Air from Outdoors -
  • Page 12 – When directly communicating with the outdoors, the single open-; Special Conditions Created by Mechanical Exhausting or Fire-; upright upflow; VII. HORIZONTAL APPLICATIONS & CONSIDERATIONS; Horizontal Furnace; Condensate
  • Page 13 – VIII. PROPANE GAS /HIGH ALTITUDE INSTALLATIONS; Natu ra l; Recommended Installation Positions; Alternate “vertical” piping connections can not be used when
  • Page 14 – DIRECT VENT TERMINAL CLEARANCES; OTHER THAN DIRECT VENT TERMINAL CLEARANCES
  • Page 15 – vent; In addition to PVC and ABS pipe and fittings, Innoflue
  • Page 16 – ELBOWS; Increased Clearance Configuration
  • Page 17 – upright installations; UPFLOW; STANDARD CONNECTIONS
  • Page 18 – Alternate Vent/Flue Location; the number of elbows in the piping system.
  • Page 19 – COMBUSTION AIR INTAKE; AX; OF; STRAIGHT; Above Highest Anticipated Snow Level; Direct vent; Standard Horizontal Terminations (Dual Pipe)
  • Page 20 – Alternate Horizontal Vent Termination (Dual Pipe); Alternate Vent Termination Above Anticipated Snow Level; Termination of Multiple Direct Vent Furnaces; upright
  • Page 21 – Hose and Tube Identification; Alternate Vent/Flue Hose Connections; Upright “Standard” Connections -Right Side
  • Page 22 – Upright “Alternate: Connections - Right Side Only
  • Page 23 – Upright “Standard” Connections - Left Side
  • Page 24 – Counterflow furnaces; Horizontal Connections - Right Side Down
  • Page 25 – sate Drain Lines and Drain Trap - Horizontal Drain Trap Mounting.; Horizontal Connections - Left Side Down
  • Page 26 – XI. ELECTRICAL CONNECTIONS; L i n e p o l a r i t y m u s t b e o b s e r v e d w h e n m a k i n g f i e l d; Remove the burner compartment door.; Junction Box Relocation; Do not use gas
  • Page 27 – Remote Condensing Unit; Field Wiring for GME95 /AMEH96 Furnacewith 2-Stage; Electronic Air Cleaner; Accessories Wiring; Wire routing must not interfere with circulator blower; Thermostat Diagram; See the following wiring schematic.
  • Page 28 – Nat ural Gas; not; derate the furnace by adjusting the manifold pressure to a; Section VIII, Propane Gas; CAUTION
  • Page 29 – Gas Piping Connections
  • Page 30 – directly
  • Page 31 – Sizing Betw een First and S econd Stage Regulator*; Propane Gas Piping Chart I; Propane Gas Piping Chart II
  • Page 32 – Both readings may be taken simultaneously and read directly; Checking Static Pressure; Airflow area will; Duct Flange Cut Outs; An undersized opening will cause reduced airflow.
  • Page 33 – Possible Upright Upflow; Possible Upright Counterflow; Filter Locations; Internal filter retention is not provided on this furnace.
  • Page 34 – AS; Inlet Gas Supply Pressure; White-Rodgers Model 36G54 Connected to Manometer; Manometer; Honeywell Model VR9205 Connected to Manometer
  • Page 35 – Manifold Gas Pressure
  • Page 36 – Temperature Rise Measurement; Startup; IRCULATOR; airflow table in the
  • Page 37 – air circulator blower fan; Adjustment Switch; Sequence of Operation (Integrated Ignition Control) – Mode; XV. NORMAL SEQUENCE OF OPERATION
  • Page 38 – XVI. OPERATIONAL CHECKS
  • Page 39 – XVIII. TROUBLESHOOTING; Troubleshooting Chart
  • Page 40 – Turn OFF electrical power to furnace.
  • Page 41 – Procedure and Adjustments; XX. BEFORE LEAVING AN INSTALLATION
  • Page 42 – TROUBLESHOOTING CHART; ON
  • Page 43 – • Circulator blower runs; LED; is flashing; FOUR; • Primary limit
  • Page 44 – BLOWER PERFORMANCE DATA; BLOWER PERFORMANCE; Model
  • Page 45 – BLOW ER PERFORMANC E; Mod el
  • Page 47 – BLOWER PERFORMANC E
  • Page 49 – WIRING DIAGRAM; IG
  • Page 52 – INSTALLATION OF CARBON MONOXIDE DETECTORS. At; EXEMPTIONS; (e) A copy of all installation instructions for all Product; SPECIAL INSTRUCTIONS FOR PRODUCTS INSTALLED
  • Page 53 – THIS PAGE LEFT INTENTIONALLY BLANK
  • Page 56 – Quality Makes the Difference!; There’s No Better Quality.”
Loading the manual

I

NSTALLATION

I

NSTRUCTIONS

*MH95/ACSH96/AMEH96/

GCH95/GME95/GCH9

G

AS

-F

IRED

W

ARM

A

IR

F

URNACE

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to know the product better than the customer. This includes all safety

precautions and related items.

Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety

warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than

when the unit is in operation.

Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer

in its safe use.

Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety

practices...follow them.

The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is

a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.

(Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace)

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

Installer: Affix all manuals adjacent to the unit.

These furnaces comply with requirements
embodied in the American National Stan-
dard / National Standard of Canada ANSI
Z21.47·CSA-2.3 Gas Fired Central Fur-
naces.

NOTE:

Please contact your distributor or our website

for the applicable Specification Sheet referred to in this manual.

Goodman Manufacturing Company, L.P.

5151 San Felipe, Suite 500, Houston, TX 77056

www.goodmanmfg.com or www.amana-hac.com

©

2006-2013 Goodman Manufacturing Company, L.P.

IO-299R
5/2013

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table of Contents

2 Table of Contents I. Component Identification ................................................................................................................................................ 5II. Safety Considerations ...................................................................................

Page 3 - WARNING; DIP

3 WARNING G OODMAN WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES. I F YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERY DAMAGE WHICH MAY RESULT. M ANY JURISDICTIONS REQUIRE A LICEN...

Page 4 - CARBON MONOXIDE POISONING HAZARD; NSTALLER; Notify carrier promptly and request an inspection.

4 I F THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY , A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE . - D O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE . - WHAT TO DO IF YOU ...

Other Goodman Models

All Goodman Other