Goodman 000 &12 - Manual
Goodman 000 &12 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CONTENTS; Installation Considerations; ABOVE FLOOR OR GRADE LEVEL.
- Page 3 – Descri ptio n; Indoor Unit Installation; Installation of Mounting Bracket
- Page 4 – Refrigerant Piping & Condensate Piping; W a l l; NOT; REFRIGERANT PIPING INSTALLATION
- Page 5 – Piping and wrapping; Outdoor Unit Installation; Outdoor Installation precautions
- Page 6 – Drain joint installation; Co rr ec t al i g nmen t; In co rr ect al ig nmen t; Refrigerant Pipe Connection; The main cause of refrigerant leaks is due to defective
- Page 7 – In order to avoid dropping burrs into the tubing,; Fl ar e n ut; Flare Connections: Firmly hold the copper pipe in a die; Electrical
- Page 9 – Te r min a ls o n t h e ind o o r u nit; Te r mi na ls on t h e i n do or u ni t; L N S; System Evacuation; Do not open valves until; Pipe Length and Refrigerant Amount
- Page 10 – Safe Refrigerant Handling; Never purge refrigerant into an enclosed room or; Never apply flame or steam to a refrigerant cylinder.; WARNING; Use caution when handling the packed valve:; Safety Check; After completing the electrical installation:
- Page 11 – Test Running
Important Safety Instructions
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owner’s and installer’s responsibility to read and comply
with all safety information and instructions accompanying these
symbols. Failure to heed safety information increases the risk
of personal injury, property damage, and/or product damage.
HIGH VOLTAGE!
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage,
personal injury or death.
Goodman will not be responsible for any injury or
property damage arising from improper service or
service procedures. If you perform service on your
own product, you assume responsibility for any
personal injury or property damage which may result.
INSTALLATION & OPERATIONS MANUAL
SPLIT TYPE ROOM AIR CONDITIONER AND HEAT PUMP MODELS
MSC/MSH 9,000 & 12,000 BTUH • 115 VOLT
© 2011 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com -or- www.amana-hac.com
IO-411
August 2011
To prevent the risk of property damage, personal injury, or
death, do not store combustible materials or use gasoline
or other flammable liquids or vapors in the vicinity of thi
appliance.
To prevent heat releated illness or death, do not use this
device for unattended cooling of persons or animals unable
to react to product failure. Failure of unattended air
conditioner may result in extreme heat in area intended
for cooling, causing heat-related illness or death of
persons or animals.
Shipping Inspection
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and subse-
quent investigation is the responsibility of the carrier. Verify
the model number, specifications, electrical characteristics,
and accessories are correct prior to installation. The distribu-
tor or manufacturer will not accept claims from dealers for trans-
portation damage or installation of incorrectly shipped units.
O
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 CONTENTS Important Safety Instructions .............................................. 1Shipping Inspection ............................................................ 1Codes & Regulations ......................................................... 2Installation Considerations .....................
3 • Select a location where noise, vibration and hot dis-charged air will not be an issue. • Do not install where high frequency equipment is used(wireless equipment, welding machine, medical facility)as it may interfere with the unit’s operation. Rooftop Installations If it is necessary to install ...
4 NOTE: Install the mounting bracket and drill the holes in the wall according to the wall structure and the correspond-ing mounting points on the mounting bracket. (Themounting brackets vary according to the model.) In corre ct orie nt a tio n of Ins ta llat ion Pl at e Corre ct orie nta tion of I ...