GermGuardian 04390-2 - Manual

GermGuardian 04390-2

GermGuardian 04390-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 2 – INTRODUCTION; READ THIS MANUAL THOROUGHLY; This symbol points out potential explosion hazard.; CONTENTS; Engine; OPERATION AND MAINTENANCE; DANGER; AUTHORIZED
  • Page 3 – Table of Contents; Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators; Section 2 – Post Installation Start-up
  • Page 4 – Owner’s Manual; GENERAL HAZARDS
  • Page 5 – ELECTRICAL HAZARDS; STANDARDS INDEX; IMPORTANT SAFETY INSTRUCTIONS
  • Page 6 – PROTECTION SYSTEMS; INTERRUPTER PROTECTION; Section 1 — General Information
  • Page 7 – GENERATOR
  • Page 9 – SYSTEM SET LED; Figure 1.3 – Demand Regulator; Full Load
  • Page 10 – sure is intended for indoor use only
  • Page 11 – BATTERY INSTALLATION; Figure 1.5 – Battery Cable Connections; • Remove the 5A and 15A fuses from the generator
  • Page 12 – BEFORE INITIAL START-UP; Section 2 — Post Installation Start-up and Adjustments
  • Page 13 – GENERATOR TESTS UNDER LOAD
  • Page 14 – Adjustment Screw; Unit
  • Page 15 – A service fee may be charged for this adjustment.; ENGINE GOVERNOR ADJUSTMENT; KW UNITS; Figure 2.3 — Engine Governor Adjustment; Full Load Speed Adjust Screw
  • Page 16 – Section 3 — Operation; Figure 3.1 – Generator Control Panel
  • Page 17 – MANUAL TRANSFER OPERATION; POWER SOURCE; Figure 3.2 – Manual Transfer Switch Operation
  • Page 18 – SOURCE; SETTING THE EXERCISE TIMER; LOW OIL PRESSURE SWITCH; Figure 3.3 – Low Oil Pressure and; OVERCRANK; Oil Filter
  • Page 19 – Approximately 90 seconds total; OVERSPEED; FUSE; Figure 4.1 – Generator Control Panel; Remove the dipstick and wipe it dry with a; Oil Dipstick and Fill; Section 4 — Maintenance
  • Page 20 – CHANGING THE ENGINE OIL; Figure 4.4 – Oil Drain Hose and Filter; CHANGING THE OIL FILTER; GENERATORS; Figure 4.6 — 7 kW, Engine Air Cleaner Location; Air Cleaner
  • Page 21 – BATTERY MAINTENANCE; Cover
  • Page 22 – COOLING SYSTEM; Figure 4.9 – Cooling Vent Locations
  • Page 23 – ATTENTION AFTER SUBMERSION; MUST NOT; CORROSION PROTECTION
  • Page 24 – SERVICE SCHEDULE; ATTENTION: It is recommended that all service work
  • Page 25 – Section 5 — Troubleshooting; GUIDE; PROBLEM; *Contact the nearest Guardian Authorized Dealer for assistance.
  • Page 26 – Section 6 — Electrical Data
  • Page 34 – Section 7 — Exploded Views and Parts Lists
  • Page 37 – DESCRIPTION
  • Page 39 – ITEM
  • Page 55 – Section 8 — Mounting Dimensions
  • Page 56 – Section 9 — Notes
  • Page 58 – CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT; YOUR WARRANTY RIGHTS AND OBLIGATIONS; ATTENTION WARRANTY DEPARTMENT
  • Page 59 – EMISSION CONTROL SYSTEM WARRANTY; EMISSION RELATED PARTS INCLUDE THE FOLLOWING:; Section 10 – Warranty
  • Page 60 – GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR GUARDIAN; WARRANTY SCHEDULE; YEARS ONE AND TWO –; THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:
Loading the manual

GENERAC

POWER SYSTEMS, INC.

R

R

Installation and

Owner’s Manual

Air-cooled, Prepackaged

Automatic Standby Generators

Models:
04389-2 (6 kW NG, 7 kW LP)
04456-2 (12 kW NG, 12 kW LP)
04390-2 (13 kW NG, 15 kW LP)

DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!!

DANGER

Not intended for use as Primary Power in place of utility or

in life-support applications.

!

!

*This manual should remain with the unit.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INTRODUCTION; READ THIS MANUAL THOROUGHLY; This symbol points out potential explosion hazard.; CONTENTS; Engine; OPERATION AND MAINTENANCE; DANGER; AUTHORIZED

Generac ® Power Systems, Inc. INTRODUCTION Thank you for purchasing this model of the Guardianproduct line by Generac Power Systems, Inc.. Thismodel is a compact, high performance, air-cooled,engine-driven generator designed to automaticallysupply electrical power to operate critical loads dur-ing a...

Page 3 - Table of Contents; Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators; Section 2 – Post Installation Start-up

Table of Contents Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Generac ® Power Systems, Inc. 1 Introduction ........................Inside Front Cover Read This Manual Thoroughly ........................IFCContents ..........................................................IFCOperation and Ma...

Page 4 - Owner’s Manual; GENERAL HAZARDS

2 Generac ® Power Systems, Inc. Study these SAFETY RULES carefully beforeinstalling, operating or servicing this equipment.Become familiar with this Owner’s Manual and with the unit. The generator can operate safely, efficientlyand reliably only if it is properly installed, operatedand maintained. M...

Other GermGuardian Models

All GermGuardian Other