DG-5 The Digital Keyless Entry System

Operation User's Manual


1. Features:

‹

4 digit codes

5 digit codes available by special order

‹

Tamper Switch Included

‹

Door Reed Switch Input for Anti-Trailing

‹

10 user PINs

‹

Fully Programmable via keypad and master code

‹

Non-Volatile

Memory

‹

Invalid PIN Lock-out


2. Specifications:

‹

Operating Voltage: 9~14 Vdc

‹

Current Draw: Average 20mA, Peak 70mA @ 12Vdc

‹

Input: One request-to-exit, and time out reed switch

‹

Relays: N.O./N.C./Com. Output (free voltage contact),
3A@ 125Vac or 30Vdc

‹

Case Material: ABS

UL94V0

‹

Operating

Temperature:-20~+70

‹

Ambient Humidity:0~95% relative humidity non-
condensing

‹

Visual

Signals:

„

Green: Power on

„

Red: Relay activated

„

Yellow: Program Mode

Lock-out

‹

Factory Master Code: 1234

‹

Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly
password attempted.

‹

Relay Activation Time:

(*

20

„

Pulse

mode

1~99 seconds

01~99

„

Latching

mode

00

‹

EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.

‹

User

PINs:

(*

01~

10

It is possible to program 10 different user PIN codes.

3. Program

Instruction:

‹

Enter Program Mode:

1. Enter the master code twice (Factory master is

1234

)

2 beeps and the Yellow LED will light up.

you are now in the "programming mode".

2.

Note:

After 60 seconds if you have not entered any codes or data, the system will

automatically exit from the programming mode. After 6 wrong attempts at the master
code the lockout facility will operate.

‹

Exiting from the program mode:

1. Press

#

to exit from the programming mode.