Gefen EXT-IP-2-RS2322 - Manual

Gefen EXT-IP-2-RS2322

Gefen EXT-IP-2-RS2322 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
Page: / 84

Table of Contents:

  • Page 2 – ii; replacement of the obsolete outlet.; Important Safety Instructions
  • Page 3 – iii; which are expressly disclaimed.; Warranty Information
  • Page 4 – c/o Customer Service; iv; Contacting Gefen Technical Support
  • Page 5 – vv; Operating Notes; Pb
  • Page 6 – Features and Packing List; Features
  • Page 7 – vii
  • Page 8 – viii; Table of Contents; Getting Started
  • Page 11 – Converter
  • Page 12 – Introduction
  • Page 13 – Name; Ge
  • Page 14 – Installation; Connection Instructions; IP control; Sample Wiring Diagram
  • Page 17 – Advanced Operation
  • Page 18 – RS-232 and IP Configuration; Configuration using the Gefen Discovery Tool
  • Page 19 – Configuration using RS-232; None
  • Page 20 – Information
  • Page 21 – Command; Commands
  • Page 23 – Displays help on a specific command. If no command is specified (; Syntax; param1; Example
  • Page 25 – Add delimiter mode to ON; Related Commands
  • Page 26 – Device Description changed to: LivingRoom_Bridge2
  • Page 27 – End delimiter set to ON with a value of ba
  • Page 29 – command. The default port setting is; New HTTP port set to: 82; dv
  • Page 30 – command. The default IP address is
  • Page 32 – Sets the send-byte count value for bridging mode.; UART 1 bridging send byte count limit is set to 100 bytes
  • Page 33 – UART 1 bridging sent Time Out is set to 30 ms
  • Page 34 – 0 characters in length. The default description is
  • Page 35 – TCP Bridge; Serial port 1 working mode is: TCP Bridge Mode
  • Page 36 – Parity
  • Page 37 – Serial port 1 parameters:
  • Page 38 – Start delimiter set to ON with a value of a0
  • Page 40 – Sets the TCP terminal listening port. The default port settings is; New TCP Terminal port set to: 23
  • Page 41 – is used to verify the new password. The default password is; TCP Terminal password updated to: b055man
  • Page 43 – Enables or disables UDP bridge echo.; Serial port; The echo of UDP Bridge port 1 is enabled
  • Page 44 – Sets the UDP server listening port
  • Page 45 – Assigns the UDP Bridge settings for the specified serial port.
  • Page 46 – notation. Each digit can range between 0 and 255.
  • Page 47 – Sets the remote UDP listening port. The default port settings is
  • Page 49 – Displays the device description.
  • Page 50 – Displays the current TCP/IP and UDP settings.
  • Page 51 – indicator will flash red and blue. The default setting is disabled.; Show me is Enabled
  • Page 52 – Displays the description of the specified serial port.
  • Page 53 – Displays the mode of the specified serial port.
  • Page 54 – Displays the current settings of the specified serial port.
  • Page 55 – Displays the current TCP terminal password.; TCP Terminal password: b055man
  • Page 56 – Displays the current software and hardware version.; Firmware version 1.48
  • Page 57 – System wide reset in progress.
  • Page 58 – The default setting is; State; Discovery Access is set to Enabled
  • Page 59 – command to configure the IP to 2 x RS-232 Converter.; TCP Access is set to Enabled
  • Page 60 – TCP Terminal password at login is set to ON
  • Page 61 – Enables or disables UDP access.; UDP Access is set to Enabled
  • Page 62 – Enables or disables UDP echo.; UDP echo is set to Enabled
  • Page 63 – Web Interface; Using the built-in Web Interface; Help
  • Page 64 – Description; Select the desired mode from the drop-down list.
  • Page 65 – Baud Rate; Data Bits; Options; Select the parity bit type from this drop-down list.; Stop Bits; Select the number of stop bits from this drop-down list.
  • Page 66 – Enter the line delay in this field.
  • Page 67 – Add Delimiters to data sent; box to enable this feature.; Use Start Delimiter; Start Delimiter Value
  • Page 68 – End Delimiter Value
  • Page 69 – Destination IP; Enter the destination port in this field.; UDP Echo; Set Defaults; Click this button to reset RS-232 settings to their default values.; Save; Click this button to save any changes.
  • Page 70 – Network tab; MAC Address; Select the network mode from the drop-down list.; IP Address; Enter the IP address of the IP to 2 x RS-232 Converter.; Subnet; Enter the subnet mask of the IP to 2 x RS-232 Converter.
  • Page 71 – Gateway
  • Page 72 – Enable TCP Access; Enables or disables TCP access.; Require Password on Connect; Forces password prompt for Telnet sessions.; User Name; is
  • Page 73 – characters; Re-type the new password in this field. The password; New Password; characters; Terminal Port; Type the Telnet listening port in this field.
  • Page 74 – Enable UDP Access; UDP Port; Range; Enable UDP Echo
  • Page 75 – Destination UDP IP Address; Enter the remote UDP IP address in this field.; Destination UDP Port; Type the remote UDP port in this field.; Enable Discovery; the Gefen Discovery Tool to detect the unit on a network.
  • Page 76 – System tab; Download (Download Current Configuration); Selects the configuration file to load. See the; Download
  • Page 77 – Click this button to select the firmware file to be uploaded.; Update; Click this button to upload the selected firmware file. See the; Factory Reset; check mark in the desired check box will select the type of reset:; Reset; Click this button to reboot the IP to 2 x RS-232 Converter.
  • Page 79 – Appendix
  • Page 80 – Default Settings; Appendix; Bridging Settings
  • Page 81 – Network; IP Settings
  • Page 82 – Operational; Specifications
Loading the manual

Audio

Embedder

3GSDI

EXT-IP-2-RS2322

User Manual

IP to RS-232

Converter

*Preferred

Release A1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ii; replacement of the obsolete outlet.; Important Safety Instructions

ii 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this product near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install ...

Page 3 - iii; which are expressly disclaimed.; Warranty Information

iii Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is notified within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipme...

Page 4 - c/o Customer Service; iv; Contacting Gefen Technical Support

iv Technical Support (818) 772-9100 (800) 545-6900 8:00 AM to 5:00 PM Monday - Friday, Pacific Time Fax (818) 772-9120 Email [email protected] Web http://www.gefen.com Mailing Address Gefen, LLC c/o Customer Service 20600 Nordhoff St. Chatsworth, CA 91311 Product Registration Register your product h...

Other Gefen Models

All Gefen Other