Page 3 - Table of Contents; Important Safety Information
iii Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Table of Contents __________________________________________ Important Safety Information .............................................................................................................................
Page 4 - Appendix B- Specifications
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved iv Chapter 4 - Maintenance and Cleaning ......................................................................................................... 4-1 Repair Policy .......................................................
Page 6 - Warnings, Cautions and Notes
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved vi WARNINGS, CAUTIONS, NOTES, and SYMBOLS: This section introduces the various types of warnings, cautions information notes and symbols used in this guide to alert you to possible safety hazards and to provide you w...
Page 7 - Symbol
vii Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved SYMBOLS: This section identifies the symbols that are displayed on the Panda iRes Warmer: Symbol Description Type BF Equipment Functional Earth Terminal Protection Earth Terminal Alternating CurrentAlarm Silence ...
Page 9 - Scope and intended users; Organization of this manual; Specifications; About this Manual
ix Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Scope and intended users This manual describes the features and operation of the Panda iRes Warmer . The Panda iRes Warmer is used in hospital delivery rooms, hospital newborn nurseries and neonatal intensive care...
Page 10 - References
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved x References References to other manuals pertaining to the Panda iRes Warmer are: • Giraffe Warmer Operation and Maintenance Manual, M1110734 • SpO 2 - Masimo SET Option, Operation and Maintenance Supplement , M11109...
Page 11 - Chapter 1; Introduction; System Description and Indications for Use; The Panda iRes Warmer includes:
1-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Chapter 1 Introduction __________________________________________ System Description and Indications for Use Infant radiant warmers provide infrared heat in a controlled manner to neonates who are unable to therm...
Page 12 - Mechanical Controls and Cable Connections; Description
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-2 Mechanical Controls and Cable Connections Figure 2: Panda iRes Warmer, front oblique view Feature number Description 1 Two dimmable observation lights 2 Aimable procedure light 3 Procedure light “On/Off” switch 4...
Page 15 - Controls and Displays; Oximetry key; “soft” keys
1-5 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Controls and Displays Figure 5: Control panel and color screen display Feature number Description 1 Power stand-by switch - On the left below the display turns the power to the warmer “On” and “Off”. 2 Oximetry k...
Page 16 - Temperature Regulation; Warmup Mode; Screen; “Check Baby”; mup Complete...”; “Admit Baby”
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-6 Temperature Regulation WARNING: Do not place the baby in the bed while in Warmup Mode. Warmup Mode is used to quickly warm and maintain heat to an empty bed. Warmup Mode is not designed for clinical use with a ba...
Page 17 - Control Modes; Baby Mode; Manual Mode; Baby Mode; white
1-7 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Control Modes The Panda Warmer has two control modes, Manual Mode and Baby Mode . In Manual Mode, the warmer controls radiant heater output from a heater power percentage setting that you enter using the control ...
Page 18 - On Screen Help; Help; “Operating Modes”; Operating Modes
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-8 On Screen Help Screen Step Description 1 Pushing the “Help” (?) key brings up Help screen that provides information about alarms and functions. When an alarm sounds, pushing the “ Help ” key automatically display...
Page 20 - Home Screen
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-10 Home Screen Screen Step Description 1 Mode Current mode setting, “ Manual” or “Baby” mode, is highlighted in blue on the left side of screen (arrow). 2 APGAR On/Off Press the “ APGAR On/Off ” key to start the AP...
Page 21 - Menu; Scale
1-11 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Scale (optional) Push the “ Menu ” key to access the “ Scale ” key. If the scale jack is not plugged in, the scale key will not appear. Push the “ Scale ” soft key to start the weighing procedure and access the ...
Page 22 - Trends; Temperature trending; SpO
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-12 Trends The warmer trends temperature, and SpO2 (optional). Push “ Menu ” key then the “ Trends ” key to display the trending screens. Temperature trending Screen Step Description 1 Push the “ Temp ” key to view ...
Page 23 - Setup; Temp Units; Alarm Volume; Pulse Tone Volume; Set Clock; Next; Elevate; Hands Free Silence
1-13 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Setup Screen Step Description 1 Push “ Menu ” on the Home Screen to access the warmer “ Setup ” key. Push the “ Temp Units ” key to change from the default Celsius (C) to Fahrenheit (F) degrees. Push the “ Alarm...
Page 24 - Manual Temperature Alarm; Man Temp Alarm
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-14 Screen Step Description 3 Patient Temperature Alarm Push the “ Pt . Temp Alarm ” key to choose between two settings in the warmer’s Baby Mode. The 0.5 setting activates an alarm when the difference between the s...
Page 25 - Alarms; Illustration; Low Priority Alarms; To silence the alarm.
1-15 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Alarms Illustration Description 1 2 3 4 There are two types alarms: Low Priority Alarms are indicated by a blinking red alarm light , a red alarm message on the central alarm area of the display, and an intermit...
Page 27 - Temperature regulation alarms; Baby Hot - Check Temp Probe
1-17 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Temperature regulation alarms Baby Hot - Check Temp Probe Screen Step Description 1 Baby Mode The “ Baby Hot - Check Temp Probe ” alarm activates when the baby’s skin tempera - ture is greater than 1.0°C above t...
Page 28 - Baby Cold-Check Temp Probe; Check Baby
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-18 Baby Cold-Check Temp Probe Screen Step Description 1 Baby Mode The “ Baby Cold- Check Temp Probe ” alarm activates when the baby’s skin temperature is greater than 1.0°C below the Set Temperature. Silencing the ...
Page 29 - Confirm Probe Jack Connection
1-19 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Check Baby-Heat Off Screen Step Description 1 Baby Mode A continuous tone sounds after the radiant heater has been running at 100% power for more than fifteen minutes, and the “ Check Baby ” alarm” has gone unan...
Page 30 - Temperature Probe Failure; Temp Probe Failure”; System Failure; Weight on scale above maximum
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 1-20 Temperature Probe Failure Screen Step Description 1 This “ Temp Probe Failure” alarm activates when the difference in the two thermistors in the skin temperature probe is greater than 0.5°C for over 6 minutes. A...
Page 31 - Alarm Table; Alarm
1-21 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Alarm Table Alarm Activation Criteria Alarm Silence Audio Signal* Mode Check Baby Radiant % power @ 100% for > 12 min. Radiant heater % above “check baby alarm disabled” limit for > 12 min. 12 min. 12 min....
Page 33 - Chapter 2; System Setup and Checkout Procedures; Mechanical checks
2-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Chapter 2 System Setup and Checkout Procedures ___________________________________________ Mechanical checks WARNING: Before using the Panda Warmer, read this entire manual. Attempting to use device without a tho...
Page 36 - Controller checks
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 2-4 Controller checks WARNING: Do not use the warmer in the presence of flammable anesthetics: an explosion hazard exists under these conditions. WARNING: Always connect the warmer directly to a hospital grade wall o...
Page 38 - “Mode”
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 2-6 Illustration Step Description 6 Unplug the skin probe and change the warm - er to Baby Mode. Check that both visual and audio alarms trigger in the Baby Mode. Silence the alarm by using either the alarm silence k...
Page 39 - Ancillary
2-7 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Ancillary equipment checks Illustration Step Description 1 Check that all ancillary equipment is securely mounted. 2 Check the operation of any ancillary equipment with reference to their appropriate operation ma...
Page 41 - Chapter 3; Operating the Warmer; Basic Operating Procedure
3-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Chapter 3 Operating the Warmer __________________________________________ Basic Operating Procedure WARNING: Always set the brakes before placing a patient in the unit . WARNING: Do not leave the patient unattend...
Page 43 - Start up
3-3 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Operating the Warmer (continued) Start up Illustration Step Description 1 Plug the unit into a properly rated AC power outlet and set the caster brakes. 2 Place the mains power switch, located by the outlets on t...
Page 45 - “Manual”; “Baby”
3-5 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Illustration Step Description 7 Place the baby in the bed WARNING: Do not place baby in bed during Warmup Mode. 8 For Baby Mode operation, connect the skin temperature probe to the temperature probe jack. In the ...
Page 47 - START; Panda iRes Warmer Flow Chart
3-7 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved START Warmup Mode Press “Admit Baby or “APGAR On/Off” Do you want to remain in Manual Mode? Panda iRes Warmer Flow Chart Press up or down heater power to desired level Is heater power less than 30%? Confirm that ...
Page 48 - Attaching the Skin temperature Probe; not
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-8 Attaching the Skin temperature Probe Illustration Step Description 1 2 3 1 Place the skin probe on the baby’s skin. If the baby is prone, place the probe on the baby’s back. If the baby is supine, you should plac...
Page 50 - Attaching the Skin Temperature Probe
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-10 Attaching the Skin Temperature Probe (continued) Illustration Step Description 2 To attach the disposable probe (single use only), peel the paper backing from the adhe - sive side and apply to the baby’s skin, w...
Page 51 - Setting the manual temperature alarm; “Menu”
3-11 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Setting the manual temperature alarm The “Man.Temp Alarm” is a safety mechanism that you can activate whenever you manage the baby’s temperature in Manual Mode. It provides a selectable alarm set point that will...
Page 53 - Raising or lowering the bedside panels
3-13 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Raising or lowering the bedside panels Illustration Step Description 1 To lower a bedside panel, pull it up and then pull the top edge away from the bed. To raise a bedside panel, swing it to the upright positio...
Page 54 - Tilting the bed
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-14 Screen Step Description 3 Remove the rear bedside panel by pressing the release button and lifting up on the panel. WARNING: The Panda iRes Warmer and Giraffe Warmer bedside panels are different heights. Use onl...
Page 55 - Raising and lowering the bed; CAUTION
3-15 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Raising and lowering the bed WARNING: Before raising or lowering the bed, check that there is adequate slack in tubing and leads and that no obstructions limit the range of motion. CAUTION Objects placed on the ...
Page 56 - Using the observation and procedure lights
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-16 Using the X-ray tray WARNING: Never place the baby on the X-ray tray. Illustration Step 1 Lower the side bedside panel and place a film cassette on the optional tray that slides out from under the mattress for X...
Page 57 - Scale installation
3-17 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Uninterruptible Power Supply (UPS) NOTE: This accessory to the Panda iRes Warmer product is available only in select markets. To understand availability within your region, contact your sales representative. The...
Page 58 - Weighing procedure; Menu’; “Weigh”
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-18 Weighing procedure The baby should be in approximately the center of the bed. Stuffed animals and other objects should not lean against bedsides. All leads, I.V. tubes and ventilator tubes should be secured. Bla...
Page 59 - “Lift Baby”
3-19 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Screen Step Description 3 You will be prompted to check “Level bed...” to ensure that the bed is level during the weighing procedure. If the bed is not level, then level the bed by sighting the bubble level on t...
Page 60 - “Replace
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-20 Screen Step Description 5 Hold the baby while the “Hold Baby” icon appears. 6 A second tone sounds and the “Replace Baby” icon appears on the screen. Place the baby back down on the mattress while hold - ing up ...
Page 61 - “Reweigh”; Reweigh; “Last weight”
3-21 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Screen Step Description 8 Push the “Reweigh” key within five minutes of the last weighing sequence if the weight is in doubt NOTE: The most likely cause for using Reweigh is failure to keep lines, tubes and medi...
Page 62 - Using the Integrated SpO; Using the Integrated Resuscitation System
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-22 Using the Integrated SpO 2 Monitor (optional) The Panda iRes Warmer can be equipped with its own integrated SpO 2 Monitor that is operated from the control panel screen. Refer to the SpO 2 Monitor setup, check o...
Page 63 - Mounting universal adapter plate.
3-23 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Illustration Description Rail system components mount to the uprights and provide access to commonly used equipment such as suction regulators, flowmeters, collection bottles, instrument shelves, etc. This paten...
Page 64 - ThermaLink; Using the Serial Data interface
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 3-24 ThermaLink The ThermaLink Serial data interface and Nurse Call connections are options offered with the Panda Warmer. Your unit has these features if there is a 9 pin connector on the back of the heater housing,...
Page 65 - Nurse Call checkout; Steps
3-25 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Nurse Call checkout Steps Description 1 Complete the basic operating procedure in chapter 3. 2 Verify proper operation of the Nurse Call station. 3 Connect the Nurse Call connector to the warmer. 4 Place the uni...
Page 67 - Chapter 4; Maintenance and Cleaning; Repair Policy
4-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Chapter 4 Maintenance and Cleaning __________________________________________ WARNING: The heater, lamps and surrounding areas are hot enough to cause skin burns. Unplug the unit and allow the heater to cool befo...
Page 68 - Maintenance schedule; Operator maintenance; Every week; Service maintenance; Annually; Every two years
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 4-2 Maintenance schedule The unit should be maintained in accordance with the preventative maintenance procedures detailed in the Service Manual. Service maintenance must be performed by a technically competent indiv...
Page 69 - Cleaning Instructions
4-3 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Cleaning Instructions After each patient use, follow your hospital’s infection control procedures for surface disinfection. Wipe down the surfaces of the warmer with a soft cloth dampened with a disinfectant-dete...
Page 70 - Cleaning the Warmer
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 4-4 Cleaning the Warmer Steps Description 1 Lower elevating base (or raise it depending upon bed height) to ergonomically comfortable cleaning position. 2 Turn bed off at standby power switch. 3 Unplug from power out...
Page 71 - Cleaning Solutions; Generic Formulation
4-5 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Cleaning Solutions Cleaning solutions that may be used safely: Generic Formulation Maximum Concentration Sodium Hypochlorite (bleach) 0.5% Aqueous Solution Glutaraldehyde 2% Hydrogen Peroxide 6% Iodophor Solution...
Page 72 - Cleaning and disinfecting individual components
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved 4-6 Cleaning and disinfecting individual components Patient Probe (reusable) CAUTION: Avoid placing excessive strain on the probe lead. When cleaning, be careful not to pull on or bend the lead at the probe tip. Alwa...
Page 73 - Cleaning other components
4-7 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Cleaning other components CAUTION: Do not clean the unit with organic solvents, scouring compounds, strong acids, or strong bases. These compounds may damage components. CAUTION: To minimize the generation of sta...
Page 75 - Appendix A; General Use Items; Ancillary Equipment
A-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Appendix A General Use Items __________________________________________ Ancillary Equipment Part Number Panda In-bed Scale 6600-0519-900 Giraffe Spot PT Light 6600-0845-800 Rotating IV Pole 6600-0851-800 IV Pole ...
Page 77 - Appendix B; Power Requirements and Accessory Outlets; Power Requirements; Standards; Designed to meet requirements of:; Operating Environment; Storage conditions; User Control Settings
B-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Appendix B Specifications __________________________________________ Power Requirements and Accessory Outlets Power Requirements Accessory Outlets 5.25 A @ 100v ~, 50/60 Hz 2 A @ 100v ~, 50/60 Hz 4.57 A @ 115v ~,...
Page 78 - Performance; System; Mechanical Specifications; Accessories; Uninterruptible Power Supply (UPS) Specifications
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved B-2 Performance System Warmer expected service life Approx. 8 years (see Note, below). Heater Element 360 Watts Heater Output 27 mW/cm 2 Patient temperature measurement accuracy ± 0.3°C @ 30°C to 42°C Temperature pro...
Page 79 - Appendix C; Electromagnetic Compatibility; Electromagnetic compatibility (EMC) guidance; Electromagnetic Emissions
C-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Appendix C Electromagnetic Compatibility __________________________________________ Electromagnetic compatibility (EMC) guidance Safety Standards: IEC 60601-1, IEC 60601-2-19 and IEC 60601-2-21, EMC Standards: IE...
Page 80 - immunity; Electromagnetic immunity; Immunity Test
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved C-2 Manufacturer’s guidance and declaration regarding electromagnetic immunity The Giraffe warmer is intended for use in the electronic environment specified below. The user of the Giraffe warmer should ensure that i...
Page 81 - declaration regarding electronic immunity; Level; Recommended separation distance
C-3 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved International Electronic Commission (IEC) guidance and manufacturer’s declaration regarding electronic immunity The Giraffe warmer is intended for use in the electronic environment specified below. The user of th...
Page 83 - Recommended separation distance between portable and mobile RF
C-5 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Recommended separation distance between portable and mobile RF communications equipment and the Giraffe warmer The Giraffe warmer is intended for use in an electromagnetic environment in which radiated RF disturb...
Page 85 - Appendix D; Conforming with Standards and Directives
D-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved Appendix D Conforming with Standards and Directives __________________________________________ GE Healthcare has declared that this product conforms with the European Council Directive 93/42 EEC Medical Device Di...
Page 87 - Statements; User Responsibility; Appendix E; Additional Safety Information
E-1 Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved. Statements WARNING: To avoid the risk of electrical shock, this equipment must only be connected to a supply mains with protective earth. The warmer does not adjust for patient temperature in warmup mode. When p...
Page 88 - Patient Temperature Control Mode; Baby Condition
Panda iRes Warmer M1110737 006 © 2007 General Electric Company, all rights reserved. E-2 Patient Temperature Control Mode In baby mode, the system performs the following adjustment every 30 seconds. The Baby Condition column indicates the difference between the baby skin temperature and the baby mod...