Page 2 - CAUTION
2 FVR-C9S-7UX CAUTION • Make sure that you read this instruction manual thoroughly before installing, wiring, operating and inspecting this drive. • Please make sure that this instruction manual accompanies the drive to the end user. • Keep this instruction manual so that it will always be available...
Page 3 - CONTENTS
3 FVR-C9S-7UX Thank you for purchasing the Fuji “FVR-C9S” drive marketed by GE Fuji Drives USA, Inc. Thisinstruction manual is included with the drive and equipment and is provided for the conve-nience of the end user. Please be sure it accompanies the drive. CONTENTS 0. Safety Precautions ............
Page 4 - Safety Precautions; FIRE AND PERSONAL INJURY HAZARD; WIRING
4 FVR-C9S-7UX 0. Safety Precautions Before carrying out installation, wiring, mainte-nance or inspection of the drive, read this in-struction manual thoroughly to gain a full under-standing of the correct operation procedures.Make sure that you have read all product details,safety information, warni...
Page 6 - Inspection Upon Receipt; Nameplate; WARNING / AVERTISSEMENT; OTHER; GENERAL CAUTION
6 FVR-C9S-7UX 1. Inspection Upon Receipt Please inspect the following items upon receiptof your drive. • Check the name plate to insure the specifica- tions correspond to those ordered. • Inspect the unit for damage which may have occurred during shipping. If you have any problems or questions regar...
Page 7 - Warning and Caution; WARNING AND CAUTION
7 FVR-C9S-7UX 1. Type 2. Phase: 1AC - Single-phase 3. Voltage range: 220V - 240V AC200V Series 4. Frequency: 50/60Hz 5. Rated output capacity 6. Rated output current 7. Output frequency range: 1- 120 Hz 8. Serial No. 2. Part Names 1. Drive Cover2. Keypad Panel3. Frequency Setting VR4. Mounting Screw...
Page 10 - External Dimensions
10 FVR-C9S-7UX 5. External Dimensions Rated Current External Dimensions: inches (mm) DWG No. Type [A] D D1 D2 FVRF12C9S-7UX 0.66 3.37 (85.5) 0.89 (22.5) 0.39 (10) FVRF25C9S-7UX 1.2 3.56 (90.5) 1.08 (27.5) 0.59 (15) DWG 1 FVRF50C9S-7UX 2.1 3.96 (100.5) 1.48 (37.5) 0.98 (25) FVR001C9S-7UX 3.7 5.53 (14...
Page 12 - Installation Instructions; Installation Conditions
12 FVR-C9S-7UX Mounting plate: Heat sink temperature will reach +90 ° C during operation. Please use thermostable material for drive mountingplate. Multi-mounting: When 2 or more drives are installed within the drive switchboard, ar-range them side by side, keeping space(shown in the above figure) b...
Page 14 - Basic Wiring Diagram; ) Keypad Panel Operation; FAB; Fault; PE
14 FVR-C9S-7UX 8. Basic Wiring Diagram 1) Keypad Panel Operation From the factory, the drive is set for frequency control by means of the potentiometer controlknob on the keypad panel. The RUN/STOP function of the drive is controlled by the RUN/STOP keys on the keypad panel. * PE terminal blocks for...
Page 15 - ) External Signal Operation
15 FVR-C9S-7UX 2) External Signal Operation Ensure that the connection is as shown in the following diagram in case of operating the driveby means of external frequency setting potentiometer or contact signal. Note 1) Set function F02 to 1. Note 2) In case of using an external frequency setting pote...
Page 16 - Application of Wiring and Equipment
16 FVR-C9S-7UX CAUTION: The control circuit terminal wiring should bekept as far as possible from the main circuitwiring to prevent operational error due tonoise interference. Never install them in thesame duct or conduit. (A separation distanceof 4 inches [10cm] or more is recom-mended.) If the con...
Page 17 - Terminal Function Explanation
17 FVR-C9S-7UX Terminal Function Explanation Classi- fication Terminal Code Terminal Name Explanation of Function Main Circuit L1, L2 Commercial power supply input terminals For connection of 1-Phase 220 to 240V commercial power supply U, V, W Drive Output Terminals For connection of a 3-Phase motor...
Page 18 - Terminal Function Explanation cont.
18 FVR-C9S-7UX Terminal Function Explanation Classi- fication Terminal Code Terminal Name Explanation of Function Output for Motor FM Analog Monitor Outputs + 10VDC between FM and CM terminals. When frquency setting is equal to the maximum frequency setting, outputs + 10VDC at 150% current when moni...
Page 19 - Frequency
19 FVR-C9S-7UX 11. Operation Pre-Operation Inspection • Check for wiring errors. • Check that all loose wire stands, metal chips and unnecessary screws, etc. havebeen removed. • Check that no screws, terminals, etc. are loose. • Check that the wire ends of crimp terminal are not in contact with othe...
Page 20 - Selecting Operation Method
20 FVR-C9S-7UX Selecting Operation Method With the FVR-C9S Series, the followingmethods can be selected to input theRUN/STOP signals and for frequencysetting. Frequency Setting Function Code setting 1 F 0 1 = 0 2 0 2 = 0 F 0 1 = 1 3 F 0 1 = 0 4 0 2 = 1 F 0 1 = 1 C92-07 * The frequency setting rate o...
Page 25 - Detailed Explanation of Each Function Code
25 FVR-C9S-7UX F 0 0 Data Protection The set data can be locked so that it will not be changed by mistake. 0 Data change possible 1 Data change not possible To change data simultaneously press the STOP key and either the UP/DOWN key. F 0 1 Frequency Command Either of the following two frequency sett...
Page 26 - Either of the following two can be selected.; F 0 9 Electronic Thermal Overload Relay Level; Motor's rated current
26 FVR-C9S-7UX F 0 7 Torque Boost Can be set from among 32 different levels in accordance with the type of load, the characteristics of the motor, etc. 0 1 2 Low 3 1 High 8 Set to match this when using a Fuji FV motor designed for use with a drive. F 0 8 Electronic Thermal Overload Relay Either of t...
Page 28 - Frequency setting
28 FVR-C9S-7UX F 1 0 Restart After Momentary Power Failure It is possible to select whether or not to restart operation when power supply is resumed after momentary power failure. 0 Inactive While stopped: Stopped condition is maintained even after power supply has been restored. While running: Afte...
Page 29 - F 1 4 Starting Frequency; F 1 5 Motor Running Sound; F 1 6 Fault Memory
29 FVR-C9S-7UX F 1 4 Starting Frequency The starting frequency can be set in increments of 1 Hz within a range of 1 to 6 Hz. Note that stopping will also occur at the frequency set by this function. 1 1 Hz 6 6 Hz Set to 2 Hz when using a high speed motor. F 1 5 Motor Running Sound The sound of the m...
Page 33 - F 3 2 FM Terminal Output Level Calibration; Approximate DC 6.5V at full scale; F 3 3 FM Terminal Function Selection; FM
33 FVR-C9S-7UX F 3 2 FM Terminal Output Level Calibration Adjust the level of the voltage output to terminal FM for the frequency meter. 0 Approximate DC 6.5V at full scale 9 9 Approximate DC 10.3V at full scale Note: The FM terminal output is a pulse output of which frequency is constant (38.1 Hz) ...
Page 34 - Protective Functions
34 FVR-C9S-7UX Function Explanation Display Alarm Output Momentary Overcurrent Protection OC1 OC2 OC3 Yes Overvoltage Protection Detects overvoltage of DC intermediate circuit and stops drive. OU Yes Undervoltage Protection Detects undervoltage of DC intermediate circuit and stops drive. LU Yes* Pro...
Page 35 - Warranty Parts and Service; Technical Services; Warranty Coverage; Motors
35 FVR-C9S-7UX 15. Warranty Parts and Service The purpose of the following section toprovide specific instructions to the user ofthe FVR-C9S-7UX drive regarding warrantyadministration and how to obtain assistanceon both in-warranty and out-of-warrantyequipment. If assistance is required to determine...
Page 36 - In-Warranty Failure Checklist
36 FVR-C9S-7UX In-Warranty Failure Checklist To assist with warranty troubleshooting, the following information is required. This data is needed to evaluatethe cause in an effort to eliminate any further failures. Model No.: Serial No.: Start-Up Date: Failure Date: Status When Failure Occurred (chec...
Page 37 - Recommended Installation Instructions
37 FVR-C9S-7UX 16. Electromagnetic Compatibility (EMC) 1. General In accordance with the provisions describedin the European Commission GuidelinesDocument on Council Directive 89/336/EEC,Fuji Electric Co., Ltd. has chosen to classifythe FVR-C9S-7UX range of drives as “Com-plex Components”. Classific...
Page 38 - Earth Stud; Table 1 RFI Filter Dimensions Conforms to EN55011 Class B
38 FVR-C9S-7UX 6) It is important that all lead length are keptas short as possible and that incomingmains and outgoing motor cables are keptwell separated. 7) Segregate power cables from controlwiring as possible as you can, and avoidparallel cable runs to minimize “noise cou-pling”. Wherever runs ...
Page 40 - Fig. 3 Recommended installation detail inside the enclosure
40 FVR-C9S-7UX Fig. 3 Recommended installation detail inside the enclosure RFI FILTER Power supplysingle-phase220-240V50/60 HZ L N PE L’ N’ L1 L2 U V W 30C30B30A [13][12][11] Alarm Signal 321 Frequency setting Potentiometer [FM][CM] (CM) (FWD) (REV) (THR) (EX) (RST) Control input M E Armored orscree...
Page 42 - EC Declaration of Conformity; Product identification
42 FVR-C9S-7UX 17. EC Declaration of Conformity We Fuji Electric Co., Ltd. Suzuka Factory5520 Minami tamagaki-cho Suzuka-city Mie-ken JAPAN declare under our sole responsibility that the following products Product identification • Product : Inverter • Brand : Fuji Electric • Model/Type : FVRO.1C9S-7...
Page 43 - Product Identification; EC Declaration of Conformity
43 FVR-C9S-7UX We Fuji Electric Co., Ltd. Suzuka Factory5520 Minami tamagaki-cho Suzuka-city Mie-ken JAPAN declare under our sole responsibility that the following products Product Identification • Product : Inverter • Brand : Fuji Electric • Model/Type : FVRO.1C9S-7xxx to FVR1.5C9S-7xxx(xxx stands ...
Page 44 - Printed in Japan
44 FVR-C9S-7UX INR Si47-0459 b-E Printed in Japan GE Fuji Drives USA, Inc.1501 Roanoke Blvd. Suite 435Salem, VA 24153 1-800-543-6196Internet Address: http://www.ge.com