Dimensions and Installation Information (in inches)

Washer Note: Washer wall outlet must be located within 36" of service cord entry.
Wall outlet must not be located behind dryer.
Dryer Note: Dryer wall outlet must be located within 36" of service cord entry and
accessible when dryer is mounted in position.

WSLP1100H

Portable

Washer

or

WSLS1100H

Stationary

Washer

DSKS433EB and

DSKS333EC

Dryer

Stack Rack

DSDR24D

22-7/8

1-5/8

5-1/2

20

79-1/4

38"

WSLP1100H

Portable

or

37-1/2"

WSLS1100H

Stationary

24-1/2

25-1/2

31-1/2

Top

Vent

WSLP1100A

Stationary

Washer

DSKS333EC

Dryer

Stack Rack

DSDR24D

22-7/8

1-5/8

5-1/2

20

77-3/4

38

25-1/2

Top

Vent

31-1/2

stack rack DSR24 w/DDP1380T

24-1/2

33-1/4

46

33-1/4

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on

a label on the dryer back.

• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other

surfaces are:
0" either side

3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a

minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open
area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with

a gas dryer.

Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local

codes, with the National Fuel Gas Code, ANSI Z223.

Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces

0" both sides

3" rear