GE AK-50 - Manual
GE AK-50 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS
- Page 3 – LIST OF FIGURES
- Page 5 – Relocating and Remounting the W and X
- Page 6 – Installing the Flux Shifter Assembly; Breakers with EC or Power Sensor Trip Systems
- Page 7 – Breakers with a Side Bracket; DO NOT
- Page 8 – Breakers with ECS or SST Trip Systems; Installing the Trip Paddle; Optional Test
- Page 9 – Installing the Trip Unit Mounting Bracket; EC or Power Sensor Trip System
- Page 11 – Crossbar Modification
- Page 12 – Removing the Existing Trip Devices; Trip Systems
- Page 13 – Installing the Phase Sensors
- Page 15 – Configuring the Trip Unit
- Page 16 – Installing the Fourth-Wire Disconnect; • If the terminal board is already present on the
- Page 19 – Installing the Neutral Sensor
- Page 21 – CONVERSION; Installing Mounting Brackets
- Page 23 – SHOOTING; Testing; Nuisance Tripping on Ground Fault-Equipped
- Page 27 – APPENDIX – DRILL TEMPLATES; Appendix 1. Drill Template for Flux Shifter Mounting
- Page 32 – purposes, the matter should be referred to the GE Company.; GE Industrial Systems
INTRODUCTION
GE Conversion Kits are designed for upgrading
existing GE low-voltage power circuit breakers,
rather than replacing the entire breaker. The Con-
version Kits include ProTrip™ Trip Units, the latest
technological advance in GE trip systems.
ProTrip Conversion Kits are designed and tested to
conform to ANSI Standard C37.59, allowing the
retrofitter to properly install the kit and acceptance
test the breaker.
This publication covers installation of ProTrip Con-
version Kits on GE types AK-50, AKU-50, AKS-50,
AKT-50, AK-75, and AK-100 low-voltage power circuit
breakers. Each Conversion Kit contains all the
components needed to convert from an existing GE
type EC trip system.
g
ProTrip™ Conversion Kits
For GE Types AK-50, AKU-50, AKS-50,
AKT-50, AK-75, and AK-100 Low-Voltage
Power Circuit Breakers
DEH–40028A Installation Instructions
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- GE
- Model
- AK-50
- Document type
- Manual
- Language(s)
- English
- Pages
- 32
- File size
- 3.7 MB
- Format
Summary
2 TABLE OF CONTENTS SECTION 1. GENERAL INFORMATION ....................................................................................................... 4 SECTION 2. BEFORE INSTALLATION .......................................................................................................... 4 SEC...
3 LIST OF FIGURES 1. Relocation and remounting of the W and X relays................................................................................. 52. New X and W relay mounting brackets................................................................................................... 53. Flux sh...
5 SECTION 3. FRONT FRAME BREAKER CONVERSION Front frame conversion consists of the followingsteps: 1. Separation of the front and back breaker frames for AK-50, AKU-50, AKS-50, and AKT-50 breakers. (Frame separation is not necessary for AK-75 and AK-100 breakers.) Refer to the appropriate installati...