Table of Contents:

  • Page 2 – IMPORTANT INFORMATION; Keep appliance area free and clear from combustibles
  • Page 3 – TABLE OF CONTENTS
  • Page 4 – DIMENSIONS AND SPECIFICATIONS GPD SERIES
  • Page 5 – INSTALLATION; Rating Plate
  • Page 6 – INSTALLATION Continued
  • Page 7 – INSTALLATION continued; Installing Under Ventilation Canopy:; ASSEMBLY INSTRUCTIONS; Leg Installation
  • Page 8 – ASSEMBLY INSTRUCTIONS Continued; Double Deck Assembly
  • Page 9 – ADJUSTMENTS; Gas Pressure Adjustments; All gas burners and pilots need sufficient air to; Flame & Air Mixture Adjustment
  • Page 10 – By-Pass Flame Adjustment; NOTE; Calibration; ADJUSTMENTS Continued
  • Page 11 – Flame Diverters; OPER ATION
  • Page 12 – CLEANING; Lighting/Shutdown Instructions; Painted Surfaces; Oven Interior; Aluminized Steel Surfaces; Core Plates; OPER ATION Continued
  • Page 13 – TROUBLESHOOTING GUIDE
  • Page 14 – NOTES
  • Page 15 – E DE
  • Page 18 – RÉG
Loading the manual

Part # 1844063 (08/06)

Page 1

INSTALLATION, OPERATING

& SERVICE INSTRUCTIONS

FOR THE

GARLAND GPD SERIES GAS PIZZA OVENS

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER

FLAMMABLE VAPORS OR LIQUIDS IN THE

VICINITY OF THIS OR ANY OTHER APPLIANCE.

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT,

ALTERATION, SERVICE OR MAINTENANCE CAN

CAUSE PROPERTY DAMAGE, INJURY OR DEATH.

READ THE INSTALLATION, OPERATION AND

MAINTENANCE INSTRUCTIONS THOROUGHLY

BEFORE INSTALLING OR SERVICING

THIS EQUIPMENT.

PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE.

THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED

BY PROFESSIONAL PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PLUMBER OR GAS FITTER. APPROVAL NUMBER: G-1-07-05-28

For Your Safety:

Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be

obtained by consulting your local gas supplier.

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine
Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,

adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided

with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified

or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer
to the Garland web site at http://w w w.garland-group.com. The information contained herein, (including design and parts

specifications), may be superseded and is subject to change without notice.

Continuous product improvement is a Garland policy, therefore design and specifications are subject to change without notice.

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES,
LTD.

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA
Phone: 905-624-0260
Fax: 905-624-5669

Enodis UK LTD.

Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

Part # 1844063 (08/06)

© 2005 Garland Commercial Industries, Inc.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - IMPORTANT INFORMATION; Keep appliance area free and clear from combustibles

Part # 1844063 (08/06) Page 2 IMPORTANT INFORMATION WARNING: This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers...

Page 3 - TABLE OF CONTENTS

Part # 1844063 (08/06) Page 3 TABLE OF CONTENTS Important Information . . . . . . . . . . . . . . . . 2 Dimensions And Specifications GPD Series . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . 5 Rating Plate . . . . . . . . . . . . . . . ...

Page 4 - DIMENSIONS AND SPECIFICATIONS GPD SERIES

Part # 1844063 (08/06) Page 4 DIMENSIONS AND SPECIFICATIONS GPD SERIES 3" [76mm] 7-15/16" [201mm] 12-1/2" [318mm] 45-1/4" [1149mm] 8" [203mm] 7-21/32" [195mm] 3/4"N.P.T. [19mm] GASINLET 14-1/2" [368mm] 23-3/8" [594mm] 24-21/32" [626mm] 28-1/2" [724mm] DECK...

Other Garland Models

All Garland Other