Fujitsu ASTG30KMTA - User Manual

Fujitsu ASTG30KMTA

Fujitsu ASTG30KMTA Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Indoor unit accessories; Remote controller holder installation; WARNING
  • Page 3 – AIR CONDITIONER Wall Mounted Type; Vertical airflow direction louver; Remote controller signal receiver; Indoor Unit Overview and Operations
  • Page 4 – Remote Controller Overview and Operations; You can quickly start operation with the following 3 steps:; Remote controller display
  • Page 5 – OPERATING MANUAL; Remote Controller Overview and Operations (continued); Signal transmitter; RESET
  • Page 6 – Timer Operation; ON timer or OFF timer; Program timer (combined use of the ON timer and the OFF timer); SLEEP timer; WEEKLY timer
  • Page 7 – To set the WEEKLY timer, first follow steps
  • Page 8 – Demand Response and Indoor Unit Operation; About the ENERGY SAVING Operation; About the HUMAN SENSOR; even when there is s; Notice; OPERATION indicator
  • Page 9 – General Informations on Operation; Automatic defrosting operation; Malfunctions caused by other electrical devices:; Heating performance; [The additional functions for wired remote controller]; [The restricted functions for wireless remote controller]; Temperature and Humidity Range
  • Page 10 – Cleaning and Care; CAUTION
  • Page 11 – Replacing dirty air cleaning filters; [Maintenance of ION DEODORIZATION FILTER]; After extended non-use of the unit
  • Page 12 – Troubleshooting
Loading the manual

En-1

AIR CONDITIONER

Wall Mounted Type

ASTG30KMTA
ASTG34KMTA

OPERATING MANUAL

Before using this product, read these instructions thoroughly. Also, keep this manual for future reference,
together with the installation manuals for the indoor and outdoor units.

Safety Precautions

To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the
following safety precautions.

Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:

WARNING

CAUTION

This mark warns of death or serious injury.

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

• Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposure to an external

ignition source, there is a risk of fire.

CAUTION

This symbol shows that the Operation Manual should be read carefully.

CAUTION

This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.

CAUTION

This symbol shows that information is available such as the Operating Manual or Installation Manual.

WARNING

• The appliance, outlet and inlet shall be installed, operated

and stored in a room with a floor area larger than X m

2

.

30 type

M (kg)

M ≤ 1.65

1.65 < M ≤ 2.05 2.05 < M ≤ 2.45 2.45 < M ≤ 2.85

X (

m

2

)

2.60

4.01

5.72

7.74

34 type

M (kg)

M ≤ 2.00

2.00 < M ≤ 2.45 2.45 < M ≤ 2.90

X (

m

2

)

3.81

5.72

8.02

M (kg): Amount of refrigerant charge ( IEC 60335-2-40 )

X (m

2

): Minimum room area

The appliance contains no user-serviceable parts. Always

consult authorized service personnel for repairing, installation,
and relocation of this product.

Improper installation or handling will cause leakage, electric

shock, or fire.

• In the event of a malfunction such as burning smell,

immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.

• Take care not to damage the power supply cable.

If the supply cord is damaged, it must be replaced by the

manufacturer, its service agent or similarly qualified persons

in order to avoid a hazard.

• In the event of refrigerant leakage, be sure to keep away

from fire or any flammables, and consult authorized service

personnel.

• If you see lightning or hear thunder, there might be a lightning

strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch this product
or the power source during thunderstorm.

• The appliance shall be stored in a room without continuously

operating ignition sources (for example: open flames, an

operating gas appliance or an operating electric heater).

The appliance shall be stored in a well-ventilated area.

• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical

damage from occurring.

• Disposing of the product shall be done properly, in

compliance with national or regional regulations.

• During transportation or relocation of the indoor unit, pipes

shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the

flammable gas to leak during operation).

(continued)

Contents

Safety Precautions ..........................................................

En-1

Indoor Unit Overview and Operations .............................

En-3

Remote Controller Overview and Operations ..................

En-4

Timer Operation...............................................................

En-6

Human Sensor (Energy Saving) ......................................

En-8

Demand Response and Indoor Unit Operation ...............

En-8

General Informations on Operation .................................

En-9

Cleaning and Care.........................................................

En-10

Troubleshooting .............................................................

En-12

R32

REFRIGERANT

This Air Conditioner contains and
operates with refrigerant R32.

THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.

Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.

PART No. 9387081015

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Indoor unit accessories; Remote controller holder installation; WARNING

En-2 OPERATING MANUAL WARNING • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person respon...

Page 3 - AIR CONDITIONER Wall Mounted Type; Vertical airflow direction louver; Remote controller signal receiver; Indoor Unit Overview and Operations

En-3 AIR CONDITIONER Wall Mounted Type OPERATING MANUAL 1 Intake grille Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing may have an effect on the proper function or performance of the product. 2 "MANUAL AUTO" button Use when the remote...

Page 4 - Remote Controller Overview and Operations; You can quickly start operation with the following 3 steps:; Remote controller display

En-4 OPERATING MANUAL CAUTION • To prevent malfunction or damage of the remote controller: - Place remote controller at where will not be exposed to direct sunlight or excessive heat. - Remove batteries if the product is not going to be used for an extended period. - Exhausted batteries must be remo...

Other Fujitsu Air Conditioners Models

All Fujitsu Air Conditioners