This Installation Manual covers the setup of MSII window-mounted air conditioners rated between 5,000–8,000 BTU, focusing on safety, hardware requirements, and precise assembly techniques. The guide emphasizes proper mounting methods–including top rail installation, filler panel fitting for double-hung windows, and adjustments for storm windows–to ensure secure placement in both wooden and vinyl-clad frames. Critical considerations like weight distribution, drainage, and airflow are addressed alongside step-by-step visual instructions to maintain functionality and compliance with safety standards.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 1 – Mounting Instructions and Safety Warnings for AC Unit
  • Page 2 – Fitting Filler Panels and Storm Window Considerations
  • Page 3 – Securing AC Unit in Window Frames
  • Page 4 – Air Conditioner Installation and Removal Procedure
Loading the manual
Page 1

READ BEFORE INSTALLING UNIT

MSII Window Mounting (5,000~8,000 BTU)

1

Installation Instructions

Before installing, the top rail must be assembled on the unit.

Philips Screwdriver

Drill (If pilot holes are needed)

TOOLS NEEDED

DO NOT USE ANY SCREWS OTHER THAN
THOSE SPECIFIED HERE.

NOTE:

SAVE CARTON and these INSTALLATION
INSTRUCTIONS for future reference. The carton is
the best way to store unit during winter, or when not
in use.

FOR SAFETY REASONS, THE TOP RAIL MUST BE
SECURELY FASTENED WITH ALL FOUR (4)
SCREWS.

A. Remove the air conditioner from the carton and place on a flat surface.
B. Remove top rail from the rear of the packaging material as shown in Fig. A
C. Align the hole in the top rail with those on the top of the unit as shown in Fig. B

'6HFXUHWKHWRSUDLOWRWKHXQLWZLWKWKHƎ6FUHZVDVVKRZQLQ)LJ&

ƎVFUHZV

7

sash lock

1

Mounting Hardware

Qty.

2

lock frame

(For Vinyl-Clad windows)

2

lock frame

(For Wooden windows)

weather seals

Ǝ;Ǝ;Ǝ

5

window sash seal foam

1

Top Rail Hardware

Qty.

4

1

Ǝ6FUHZ

Top Rail

Some assembly is required. Please read these instructions
carefully.

2020211A1446

Fig. B

Packaging

Fig. A

Fig. C

Top Rail

The unit is for window mounting only.

INSTALLATION WARNINGS AND CAUTION

Pay attention to danger and safety notices.

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.

Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Frigidaire
Model
FRA065AT7
Document type
User Manual
Language(s)
English
Pages
4
File size
561.2 KB
Format
PDF

Other Manuals for Frigidaire FRA065AT7

Summary

Page 1 - Mounting Instructions and Safety Warnings for AC Unit

Installation instructions, required hardware, tools, and step-by-step assembly for mounting the MSII Window Mounting air conditioner (5,000–8,000 BTU), including safety cautions regarding weight and handling.

Page 2 - Fitting Filler Panels and Storm Window Considerations

Installation procedures for left and right filler panels, specific measurements for fitting the unit into double-hung windows, and considerations for installing or removing storm windows to ensure proper airflow and drainage.

Page 3 - Securing AC Unit in Window Frames

Numbered instructions and diagrams detailing how to position the air conditioner, extend side panels, place a frame lock, and drive locking screws for securing the unit in both wooden and vinyl-clad windows.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.