Friedrich S24YF - Manual
Friedrich S24YF – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Ductless Split Systems
Floor/Ceiling Universal Heat/Cool - S24YF
PURCHASER
P.O. #
DATE
PROJECT
LOCATION
ENGINEER
ARCHITECT
SUBMITTED BY
FOR APPROVAL
FOR REFERENCE
ITEM
PLAN DESIGNATION
QUANTITY
COOLING BTU/H
VOLTAGE
FRIEDRICH MODEL
Ductless_Floor_Ceiling_S24YF_Submittal_08
Features
• Auto-swing louvers (up/down, lef t/right)
• Auto-restar t
• Auto-shut flaps
• Washable, reusable air f ilters
• Fresh air capability
Wireless Remote
• 24 -hour timer
• Sleep timer
• Auto, cool, dr y, fan and heat modes
• Three fan speeds plus auto-fan
• Four dif ferent transmitter codes
• Secured remote control holder
MOUNTS ON THE CEILING
OR ON THE FLOOR
PERFORMANCE RATINGS
SYSTEM MODEL NO.
S24YF
INDOOR MODEL
MS24Y3F
OUTDOOR MODEL
MR24UY3F
Capacity Cooling
BTU/h
22200
Capacity Heating
@
47°F
BTU/h
24200
Capacity Heating
@
17°F
BTU/h
20100
HSPF
8.5
SEER
15.0
Moisture Removal
Pts/h
7.4
Airflow (Low, Med, High)
CFM
371/436/518
Sound Rating - Indoor
dB-A
38/43/47
Sound Rating - Outdoor
dB-A
53
Operating Range COOL
(HEAT)
°F
0 to 115
(14-75)
ELECTRICAL DATA
Power Source
230/208-60-1
Min. Ampacity
A
15.5
Cooling Watts
W
2250
Max. TD Fuse/Breaker
A
20
REFRIGERATION SYSTEM
Refrigerant
R410A
Compressor Type
Inver ter (Twin Rotary)
Connections
Flare
Liquid Line O.D.
in
3/8
Suction Line O.D.
in
5/8
Factory Precharge
ft
50
Max. Line Length
ft
165
Max. Height Difference
ft
66
DIMENSIONS & WEIGHT
INDOOR UNIT
W x H x D
in
39 x 7
7
/
8
x 25
3
/
4
Net Weight
lbs
62
Shipping Weight
lbs
82
OUTDOOR UNIT
W x H x D
in
35
3
/
8
x 32
5
/
8
x 13
Net Weight
lbs
141
Shipping Weight
lbs
154
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.