Friedrich MW24C3G - Manual

Friedrich MW24C3G

Friedrich MW24C3G – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
Page: / 21

Table of Contents:

  • Page 2 – S P E C I F I C A T I O N S
  • Page 3 – D I M E N S I O N S; OUTDOOR UNIT
  • Page 4 – Strainer; Heat exchanger; Refrigerant pipe diameter
  • Page 5 – TEST; INDOOR UNIT; C I R C U I T D I A G R A M
  • Page 6 – INDICATOR PCB ASSEMBLY; CONTROLLER PCB ASSEMBLY; I N D O O R P C B
  • Page 9 – O U T D O O R P C B
  • Page 11 – E R R O R D E T E C T I O N
  • Page 13 – P A R T S; Ref
  • Page 19 – 6 Terminal Bracket
  • Page 20 – Name and Shape; Remote control; A C C E S S O R I E S
Loading the manual

SPLIT TYPE
ROOM AIR CONDITIONER
WALL WOUNTED TYPE

C O N T E N T S

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . .

1

DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . .

2

REFRIGERANT SYSTEM DIAGRAM . . . . .

3

CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . .

4

ERROR DETECTION . . . . . . . . . . . . . . . .

5

INDOOR PCB CIRCUIT DIAGRAM . . . . . .

8

OUTDOOR PCB CIRCUIT DIAGRAM . . . .

10

PARTS (indoor unit) . . . . . . . . . . . . . . . . .

12

PARTS (outdoor unit) . . . . . . . . . . . . . . . .

16
19

ACCESSORIES . . . . . . . . . . . . . . . . . . . .

Indoor unit

Outdoor unit

MW24C3G

MR24C3G

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - S P E C I F I C A T I O N S

1 2010.11.02 S P E C I F I C A T I O N S INDOOR UNIT MW24C3G OUTDOOR UNIT MR24C3G COOLING CAPACITY 24,000 BTU, 7.03 kW POWER SOURCE 208 / 230 V FREQUENCY 60 Hz RUNNING CURRENT 10.5 A INPUT WATTS 2.4 kW E.E.R. 10.0 BTU/hW, 2.93 kW/kW MOISTURE REMOVAL 6.3 Pt/h, 3.0 L/hr AIR CIRCULATION HIGH 659 cfm, 1...

Page 3 - D I M E N S I O N S; OUTDOOR UNIT

D I M E N S I O N S Unit : inch (mm) OUTDOOR UNIT Drain hose length : 26-3/8 inch (670 mm) INDOOR UNIT 39-1/4 (998) 9 (228) 12 -5 /8 (3 20 ) 2 2010.11.02 11-13/32 (290) 31-3/32 (790) 21-1/4 (540) 24 -1 3/ 32 (6 20 )

Page 4 - Strainer; Heat exchanger; Refrigerant pipe diameter

R E F R I G E R A N T S Y S T E M D I A G R A M 2-way valve Strainer 3-way valve Muffler Expansion valve Heat exchanger (Indoor unit) Heat exchanger (Outdoor unit) Sub-accumulator Compressor Refrigerant direction Refrigerant pipe diameter Liquid : 1/4" (6.35 mm) Gas : 5/8" (15.88 mm) 3 2010....

Other Friedrich Models