Page 3 - Notices for use; Installation service; Do not dispose this product as unsorted municipal waste.; Friedrich Air Conditioning; Typical Unit Components; installation; Typical Unit Dimensions; Checklist
CONTENTS This symbol stands for the items should be forbidden. This symbol stands for the items should be followed ■ ■ ■ ■ ■ ■ ■ ■ Operation and maintenance Notices for use ■ Installation service Install indoor unitInstall outdoor unit Do not dispose this product as unsorted municipal waste. Collect...
Page 4 - Here are some suggestions to help you use your; Do not block the air flow to and from the unit.; Refrigeration system; Keep window coverings away from the unit to provide free air flow.; NOTICE; CAUTION; Your safety and the safety of others are very important.; WARNING
Congratulations Thank you for your decision to purchase Friedrich. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable, efficient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit...
Page 5 - Working principle and special functions for cooling
* * * * * * Notices for use Working principle and special functions for cooling Principle: Anti-freezing function: Working principle and special functions for heating Principle: Defrosting: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so thatindoor ambient tempera...
Page 6 - for cooling and heating unit is; Working temperature range; Maximum cooling
Notices for use Anti-cool wind function: In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't 2 mins): 1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature. The operating temperature range (outdoor temperature) for coolin...
Page 8 - CLOCK; Press it to set auto-off timer; Operation of Remote Controller; Press to start or stop operation.; : Press to increase temperature; Press to set fan speed.; SENSOR
MODE (AUTO/COOL/DRY/FAN/HEAT). setting. : Press to decrease temperature setting. FAN Press it set swing angle. TIMER ON TIMER OFF CLOCK TEMP TURBO SLEEPLIGHT Press it to set auto-on timer. Press it to set auto-off timer Press it set clock. 1 6 7 5 3 2 4 11 10 14 9 12 13 15 Operation of Remote Contro...
Page 9 - After pressing TIMER button, ON or; AIR SWEEP
This area will show the set tempe-rature. In SAVE mode,"SE" will be displayed. During defrosting opera-tion, “H1” will be displayed. DIGITAL display: LOCK icon: is displayed by pressing "+" and “-” buttons simultaneously. Press them again to clear the display. LIGHT icon: is displaye...
Page 10 - EXTEND
is displayed when pressing the again to clear the display. Press FAN button to select thedesired fan speed setting (AUTO- Low-Med-High).Your selection willbe displayed in the LCD windows,except the AUTO fan speed. FAN SPEED display: is displayed when pressing the to clear the display. Operation of R...
Page 11 - . Hold it down for above 2 seconds to; Remote Control Instructions
Press ing CLOCK button, blink s . Within 5 seconds , pressing + or - button adjusts the present time. Holding down either button above 2 seconds increases or decreases the CLOCK : time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During blinking after setting, press CLOCK bu...
Page 12 - pressing; By pressing this button you can display
13 TEMP: ambient temperature, 5s later or within 5s, it receives other remote control signal that will return to display the setting temperature. if the users haven't set up the temperature displaying status,that will display the setting temperature.(This function is not applicable for some models)....
Page 13 - or DRY mode to maintain the most; Allows you to toggle between Fahrenheit and Celsius.; function. This function is available in COOL
★ ● ● ●● ● 1.Remove the battery cover plate from the rear of the remote controller. (As shown in the figure) 2.Take out the old batteries. 3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 4. Reinstall the battery cover plate. When replacing the batteries, do not use old or ...
Page 14 - Emergency operation; speed cannot be changed. The operation; Front Panel Illumination On/Off; on the remote controller screen by pressing this; button. At this time, the unit will run the
If the wireless remote control is lost or broken, please use the manual switch Auto mode, but the temperature and fan pressing this button. In which case,the diss-player indicator light will be on if the AC receives be off if the AC receives this signal. ● ● display on the remote controller screen b...
Page 15 - Take down the air filter; Insert the air filter; Routine Maintenance
℃ ● ● ● ● ● ℃ ② Clean the air filter ③ ① ( a ) ( b ) Caution Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile liquid (...
Page 16 - C a u s e
T h e s o u n d o f w a t e r f l o wd u r i n g o p e r a t i o n . ● Tu r n u n i t o n . ● R a i s e / L o w e r t e m p e r a t u r e s e t t i n g . ● U n i t w i l l r e s u m e n o r m a l o p e r a t i o n o n c e p o w e r h a s b e e n r e s t o r e d . ● C l e a n a i r f i l t e r. ● C l...
Page 18 - Immediately stop all operations and plug out, contact; There is harsh sound during operation; Turn off unit and switch off breaker.
C a u s e Immediately stop all operations and plug out, contact the dealer in following situations occur. There is harsh sound during operation . The terrible odors emitted during operation . Water is leaking in the room . Air switch or protection switch often breaks . There is an abnormal heat in p...
Page 19 - S e r v i c e & A s s i s t a n c e; a l i s t o f a v a i l a b l e s e r v i c e s :
S e r v i c e & A s s i s t a n c e Tr o u b l e s h o o t i n g " s e c t i o n a n d s t i l l n e e d h e l p , h e r e i s a l i s t o f a v a i l a b l e s e r v i c e s : 1 2 3 15
Page 20 - Important Notices; Placement
1. 2. Select a position where the condensing water can be easily drained out, and the place is easily connected for outdoor unit. 4. Can select the place where is strong enough to withstand the full weight and vibration of the unit. And will not increase the noise. 5. 6. 7. 8. Make sure that the ind...
Page 21 - Safety Requirements For Electric Appliances; Installation; needs to be properly grounded.; requirements
Safety Requirements For Electric Appliances Note: Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected, there should be reliable and no short circuit in the diagram. wrong connection may cause fire. ● ● 1. The power supply should b...
Page 22 - Space to the wall
Space to the wall e v o b A e v o b A Installation dimension diagram Space to the ceiling Space to the wall Space to the wall Air outlet side Space to the floor Above Above Above Above Above The dimensions of the space necessary for correct installation of the appliance including the minimum permiss...
Page 23 - Install indoor unit; Install the rear panel; Install the piping hole; Flooded; Connect indoor and outdoor electric wires; BU
Install indoor unit Ø 5 5 Install the rear panel 1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the outlet of the water tray as t...
Page 24 - Install the indoor unit
● ● ● After tighten the screw, slight pull the wire and confirm whether is it firm or not. ● ● The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that Install indoor unit NOTE: When connecting the electric wire if the wire length is not enough, please contact wi...
Page 25 - Air purging and leakage test
Ø Condensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:set the drain connection in 25 hole of the chassis has been installed and then connect drainage p...
Page 26 - Check after installation; Items to be checked; Test Operation; is completely finished.
1. (2) Electric wiring must be connected correctly and securely. (3) Cut-off valves of the connection pipes should be opened. (4) 2. the operation. (2) Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop, shake or emit noise. Have you done th...