Friedrich CP05 - Manual

Friedrich CP05

Friedrich CP05 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – INTRODUCTION; TABLE OF CONTENTS; TYPICAL UNIT COMPONENTS
  • Page 3 – FIRST YEAR
  • Page 4 – ROUTINE MAINTENANCE
  • Page 5 – UNIT IDENTIFICATION; RAC Serial Number Identifi cation Guide
  • Page 6 – PERFORMANCE DATA; Casement
  • Page 7 – ELECTRIC SHOCK HAZARD.; ELECTRICAL DATA
  • Page 8 – ELECTRONIC CONTROLS; FUNCTIONAL COMPONENT DEFINITIONS
  • Page 10 – IMPORTANT; Refrigerant System Components; REFRIGERATION SYSTEM SEQUENCE OF OPERATION; SEALED REFRIGERATION SYSTEM REPAIRS
  • Page 12 – REFRIGERANT CHARGING; METHOD OF CHARGING
  • Page 13 – REFRIGERANT CHARGING cont’d
  • Page 14 – RESTRICTED REFRIGERANT SYSTEM
  • Page 15 – NORMAL FUNCTION OF VALVE; POSSIBLE CAUSES; MALFUNCTION OF VALVE; TROUBLESHOOTING TOUCH TEST CHART: TO SERVICE REVERSING VALVES
  • Page 16 – COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
  • Page 20 – HEAT / COOL ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
  • Page 21 – TROUBLESHOOTING CHART — COOLING; REFRIGERANT SYSTEM DIAGNOSIS – HEATING
  • Page 22 – ELECTRICAL TROUBLESHOOTING CHART — HEAT PUMP; YES; TROUBLESHOOTING CHART — HEATING; REFRIGERANT SYSTEM DIAGNOSIS – HEATING; SYSTEM COOLS WHEN
  • Page 23 – MODEL
  • Page 24 – MODELS
Loading the manual

Ser vice Manual

Room Air Conditioners

RAC-Svc-06 (3-06)

2006

Cool

SUPER HIG

H EFFICIEN

CY

Temp/Hour

Fan Only
Clock
Start
Stop

MoneySaver

®

PM

Vent shut

Exhaust

Fan

Speed

Timer

On/Off

Set

Hour

Power

On/Off

Mode

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INTRODUCTION; TABLE OF CONTENTS; TYPICAL UNIT COMPONENTS

2 INTRODUCTION This service manual is designed to be used in conjunction with the installation manuals provided with each air conditioning system component. This service manual was written to assist the professional RAC service technician to quickly and accurately diagnose and repair malfunctions. T...

Page 3 - FIRST YEAR

3 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purcha...

Page 4 - ROUTINE MAINTENANCE

4 ROUTINE MAINTENANCE NOTE: Units are to be inspected and serviced by qualifi ed service personnel only. Inspect the indoor blower housing, evaporator blade, condenser fan blade, and condenser shroud periodically (yearly or bi-yearly) and clean of all debris (lint, dirt, mold, fungus, etc.) Clean the...

Other Friedrich Models

All Friedrich Other