Franklin TB15CI - Manual

Franklin TB15CI

Franklin TB15CI – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 3 – ELECTRICAL SAFETY; DO NOT touch an operating motor.; GENERAL SAFETY; W A R N I N G; INTRODUCTION
  • Page 4 – INSTALLATION; LOCATION OF PUMP; Figure 1
  • Page 5 – PLUMBING; Figure 2
  • Page 6 – Figure 4
  • Page 7 – NOTICE; READ AND FOLLOW ALL INSTRUCTIONS!; Pump connection must comply with National; WARNING; Date of Installation:; DUAL VOLTAGE ADJUSTMENT; Wiring Installation; Figure 6
  • Page 8 – MAINTENANCE; Do not run pump against
  • Page 9 – Diffuser; Figure 8
  • Page 10 – Figure; APPENDIX I
  • Page 11 – APPENDIX II - TROUBLESHOOTING
  • Page 12 – APPENDIX III - PERFORMANCE CURVE
  • Page 13 – APPENDIX IV - FRICTION LOSS TABLES
  • Page 14 – the above may not apply to you.; with the sale of its products.; MAY VARY FROM STATE TO STATE.
  • Page 15 – MANUAL DEL PROPIETARIO; Bomba para regadores autocebante; ANTES DE COMENZAR; P E L I G R O; AV I S O; C U I D A D O; causarán; AV I S O; PRESIÓN PELIGROSA; C U I D A D O; C U I D A D O
  • Page 17 – SEGURIDAD ELÉCTRICA; NO toque el motor en funcionamiento.; SEGURIDAD GENERAL
  • Page 18 – VERIFICACIÓN ANTES DE LA INSTALACIÓN; INSTALACIÓN; UBICACIÓN DE LA BOMBA; OPCIÓN DE INSTALACIÓN DE BOMBA INTERNA:; Figura 1
  • Page 19 – TUBERÍAS; Puntos de Múltiples Pozos llanos (Figura 2); DIST; Figura 3
  • Page 20 – Figura 5; Figura 4
  • Page 21 – REGISTROS DE LA INSTALACIÓN; Fecha de la instalación:; INSTALACIÓN ELÉCTRICA; ¡LEA Y SIGA TODAS LAS INSTRUCCIONES!; Figura 6; AVISO; Instalación del cableado
  • Page 22 – Figura 7; MANUTENCIÓN
  • Page 23 – C. Montaje de la Bomba; Difusor
  • Page 24 – APÉNDICE I
  • Page 25 – APÉNDICE II - SOLUCIÓN DE PROBLEMAS
  • Page 26 – APÉNDICE III - CURVA DE DESEMPEÑO
  • Page 27 – APÉNDICE IV - TABLAS DE PÉRDIDA DE FRICCIÓN
  • Page 28 – GARANTÍA LIMITADA EN ESTADOS UNIDOS*; garantía de sus proveedores a Franklin Electric.; anterior puede no aplicarse en este caso.
  • Page 29 – GUIDE D’UTILISATION; Pompe d’arrosage auto-amorçante; AVANT DE COMMENCER; entrainera; PRESSION DANGEREUSE; AT T E N T I O N
  • Page 31 – ÉLECTRICITÉ ET SÉCURITÉ; à l’alimentation électrique.; NE PAS TOUCHER un moteur en; SÉCURITÉ GÉNÉRALE
  • Page 32 – Puits de surface unique ( illustration 1 ); INSPECTION AVANT INSTALLATION; EMPLACEMENT DE LA POMPE; Illustration 1
  • Page 33 – TUYAUTERIE; Réseau de pointes fi ltrantes ( illustration 2 ); Illustration 3
  • Page 35 – REMARQUE; RÉGLAGE DU MOTEUR BITENSION; Illustration 6; Câblage
  • Page 36 – Illustration 7; PRESSION dangereuse !
  • Page 37 – C. Montage de la pompe; Illustration 9
  • Page 38 – No; ANNEXE I
  • Page 39 – ANNEXE II : DÉPANNAGE
  • Page 40 – ANNEXE III - COURBE DE RENDEMENT
  • Page 41 – ANNEXE IV - TABLEAUX DES PERTES DE CHARGE
  • Page 44 – DÉTENIR D’AUTRES DROITS, QUI PEUVENT DIFFÉRER SELON LES ÉTATS.; concernant la garantie internationale.
Loading the manual

OWNER'S MANUAL

Self Priming Sprinkler Pump

BEFORE YOU START

BEFORE INSTALLING PUMP, BE SURE TO READ
THIS OWNER’S MANUAL CAREFULLY.

REFER TO PRODUCT DATA PLATE(S) FOR
ADDITIONAL OPERATING INSTRUCTIONS AND
SPECIFICATIONS.

• Keep work area clean, well-lit and uncluttered.

• Keep safety labels clean and in good condition.

• Replace missing or damaged safety labels.

• Wear safety glasses while installing or performing
maintenance on pump.

• Adhere to the guidelines of the National Electric Code
(NEC) or Canadian Electric Code (CEC), and any other
state and local codes for ALL electrical installations.
Check with the appropriate agencies or contact a
licensed electrician.

Most water system problems result from improper
installation. It is suggested that you read this
manual carefully before installing your pump. The
“TROUBLESHOOTING SECTION” will assist you in
locating and eliminating the cause of any trouble you
may encounter after installation. Check and make
available all the tools you will need to install your pump.
Required tools may include wrenches, pipe sealant, pipe
fi ttings and nipples, screwdriver, etc.

READ AND FOLLOW SAFETY INSTRUCTIONS

This is the safety alert symbol. When you see
this symbol on your pump or in this manual, look

for one of the following signal words and be alert to the
potential for personal injury:

D A N G E R

warns about hazards that

will

cause

serious personal injury, death or major property damage
if ignored.

W A R N I N G

warns about hazards that

can

cause

serious personal injury, death or major property damage
if ignored.

C A U T I O N

warns about hazards that

will

or

can

cause minor personal injury or major property damage if
ignored.

NOTICE

indicates special instructions, which are

important but not related to hazards.

Carefully read and follow all safety instructions in
this manual and on pump.

HAZARDOUS PRESSURE

: Do not run

pump against closed discharge. Release all system
pressure before working on any component.

Do not run pump dry. Fill pump with

water before starting or pump will be damaged.

The motor on this pump is guaranteed by the
manufacturer and in event of failure it must be returned
to an authorized service station for repairs. Motor
warranty is void if repairs aren’t made by an authorized
repair station.

W A R N I N G

W A R N I N G

C A U T I O N

C A U T I O N

W A R N I N G

Be sure to have available proper and adequate wiring
material to complete the installation correctly.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - ELECTRICAL SAFETY; DO NOT touch an operating motor.; GENERAL SAFETY; W A R N I N G; INTRODUCTION

1 ELECTRICAL SAFETY C A U T I O N Make sure all ELECTRICAL POWER IS OFF before connecting any electrical wires. W A R N I N G Capacitor voltage may be hazardous. To discharge motor capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together. Do not touch metal s...

Page 4 - INSTALLATION; LOCATION OF PUMP; Figure 1

2 Following are three well and water source applications for the Turf Boss sprinkler pump. Wells may differ slightly but the application is essentially the same. Single Shallow Well (Figure 1) The single shallow well is typically a drilled well with a 4" or 6" steel or plastic casing running...

Page 5 - PLUMBING; Figure 2

3 Lake Or Pond Installation (Figure 3) Using a surface water source such as a lake or pond is similar to using a single shallow well. The suction pipe is placed in the water source and leads back to the pump. This application may require a long horizontal distance between water source and pump. The ...

Other Franklin Models

All Franklin Other