FMI VFN30R - Manual

FMI VFN30R

FMI VFN30R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
Page: / 26

Table of Contents:

  • Page 2 – DANGER: Carbon monoxide; Carbon Monoxide Poisoning:; WARNINGS; Note; WARNING: Any change to
  • Page 3 – OWNER’S MANUAL; Figure 1 - Ember Master; Where listed vented decorative logs are; CAUTION: Do not remove the; OPERATION; LOCAL CODES; Continued; UNPACKING
  • Page 4 – Unusually Tight Construction; per
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
  • Page 6 – Figure 2 - Ventilation Air from Inside Building; Ventilation Air From Outdoors; Do not provide openings; Figure 3 - Ventilation Air from Outdoors
  • Page 7 – CHECK GAS TYPE; INSTALLATION; When installing your gas logs
  • Page 8 – If Using Mantel; If using a mantel, see If Using; Installing Damper; Noncombustible material OK.
  • Page 9 – MANTEL CLEARANCES; Figure 6 - Minimum Mantel Clearances Without Using Hood; FLOOR CLEARANCES; A. If installing appliance on the floor level,; flue damper open
  • Page 10 – Area of Various Standard; Figure 10 - Attaching Damper Clamp; Manufactured Fireplace; Installation Items Needed
  • Page 11 – WARNING A qualified service; WARNING: Never connect; CAUTION: Avoid damage to; Figure 13 - Gas Connection
  • Page 12 – Figure 15 - Checking Gas Joints; Figure 14 - Equipment Shutoff Valve; WARNING: Never use an open; Correct all leaks at once.
  • Page 13 – INSTALLING LOGS
  • Page 14 – FOR YOUR SAFETY; Figure 21 - Control Knob and Ignitor Button Location
  • Page 15 – Shutting Off Heater; WARNING: Make sure the; Thermostat Control Operation; Lighting Instructions on; GHRC Series Operation:
  • Page 16 – Figure 25 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; This remote control; The hand-held remote; To turn the pilot off,
  • Page 17 – WARNING: If yellow tipping; WARNING: Turn off heater; Figure 30 - Pilot Inlet Air Hole; LOGS; • If you remove logs for cleaning, refer to
  • Page 18 – POSSIBLE CAUSE; TROUBLESHOOTING; REMEDY; All troubleshooting items are listed in
  • Page 19 – nance, page 17) or replace burner orifice; OBSERVED PROBLEM
  • Page 20 – IMPORTANT
  • Page 21 – PARTS UNDER WARRANTY; SPECIFICATIONS; When Gas Pressure is Too Low
  • Page 23 – PARTS LIST; KEY
  • Page 24 – FIREPLACE HOOD; ACCESSORIES
  • Page 25 – NOTES
  • Page 26 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; INTERNATIONAL
Loading the manual

UNVENTED (VENT-FREE)

NATURAL GAS LOG HEATER

VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED AS

VENTED DECORATIVE APPLIANCES

OWNER’S OPERATION AND INSTALLATION MANUAL

Save this manual for future reference

VFN18R
VFN24R
VFN30R

18", 24", and 30"

Remote-Ready

EMBER MASTER

PI

LOT

O

F

F

O

N

LO

REMOTE

OFF

ON

HI

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

— Installation and service must be per-

formed by a qualified installer, service
agency, or the gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to

Air for Combustion and Ventilation section on page 4 of this manual.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design-
certified for these installations in accor-
dance with ANS Z21.11.2. Exceptions: Do
not install this appliance in a factory-built
fireplace that includes instructions stat-
ing it has not been tested or should not be
used with unvented gas logs.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DANGER: Carbon monoxide; Carbon Monoxide Poisoning:; WARNINGS; Note; WARNING: Any change to

2 105072 UNVENTED NATURAL GAS LOG HEATER FIREPLACE MANUFACTURERS INC. 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• shut off gas supply• do not try to light any appliance• do not tou...

Page 3 - OWNER’S MANUAL; Figure 1 - Ember Master; Where listed vented decorative logs are; CAUTION: Do not remove the; OPERATION; LOCAL CODES; Continued; UNPACKING

3 105072 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Ember Master Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode, ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute...

Page 4 - Unusually Tight Construction; per

4 105072 UNVENTED NATURAL GAS LOG HEATER FIREPLACE MANUFACTURERS INC. Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the cold ...

Other FMI Models

All FMI Other